106671-6641 ZEXEL 9 400 616 917 BOSCH INJECTION-PUMP ASSEMBLY 9400616917 1066716641 1156034520


 

Information injection-pump assembly

BOSCH 9 400 616 917 9400616917
ZEXEL 106671-6641 1066716641
ISUZU 1156034520 1156034520
106671-6641 INJECTION-PUMP ASSEMBLY
Rating:
45
Buy INJECTION-PUMP ASSEMBLY 106671-6641 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-6641 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-6701
3. GOVERNOR 105960-0431
4. SUPPLY PUMP 105237-4731
5. AUTOM. ADVANCE MECHANIS 105681-2820
6. COUPLING PLATE 105664-0881
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-8201
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 17.7(180)/22.1(225)
13. NOZZLE-HOLDER 105041-4371
14. NOZZLE
15. NOZZLE SET 105019-2730

Include in #1:

106671-6641 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-6641 
106671-6710 
9 400 616 917 
1156034520  ISUZU
INJECTION-PUMP ASSEMBLY
6WG1-T * K




Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The battery is a replaceable lithium battery. The battery provides backup power for approximately two years. The "BATT" LED on the front of the processor alerts you when the battery voltage has fallen below a threshold level.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The red "BATT" LED is illuminated. The battery voltage has fallen below a threshold level.The red "BATT" LED is not illuminated. The battery is functional.
Illustration 1 g00563546
Diagram of the LED indicators
Illustration 2 g00563548
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Verify that the battery is connected.
Verify that the battery is properly connected.The results of the preceding procedure are in the following list:
The battery is properly connected. Replace the battery. Verify that the repair resolves the problem. Refer to Maintenance Procedure, "Battery - Replace". Stop.
The battery is not properly connected. Proceed to 3.
Replace the battery.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Secure power to the processor.
Press the retaining clips at the top of the processor and press the retaining clips at the bottom of the processor.
Remove the processor from the chassis.
To avoid potential damage to the processor, handle all modules by the ends of the carrier or edges of the plastic housing. Skin oil or dirt can corrode metallic surfaces, inhibiting electrical contact.
Disconnect the battery. Remove the battery.
Install the new battery. Connect the new battery.
Align the processor and the guides in the chassis.
Gently slide the processor in the chassis. Secure the top retainer clips and secure the bottom retainer clips.
Install a wire tie in order to secure the wiring.The results of the preceding procedure are in the following

Have questions with 106671-6641?





Group cross 106671-6641 ZEXEL

Isuzu 

9 400 612 567 
1156034340 
INJECTION-PUMP ASSEMBLY
6HK1-XQB
9 400 616 915 
1156034360 
INJECTION-PUMP ASSEMBLY
6SD1-T
F 019 Z10 737 
1156034390 
INJECTION-PUMP ASSEMBLY
6SD1-X
9 400 613 060 
1156034391 
INJECTION-PUMP ASSEMBLY
6SD1-X
9 400 616 916 
1156034380 
INJECTION-PUMP ASSEMBLY
6WG1-T
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

106671-6641  

106671-6710 
9 400 616 917 
1156034520 
INJECTION-PUMP ASSEMBLY
6WG1-T
9 400 612 756 
1156034540 
INJECTION-PUMP ASSEMBLY
6WG1-T
 
1156034691 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 616 918 
1156034693 
INJECTION-PUMP ASSEMBLY
6HK1-T
 
1156034710 
INJECTION-PUMP ASSEMBLY
6HE1-TMC
9 400 616 919 
1156034711 
INJECTION-PUMP ASSEMBLY
6HE1-TMC
 
1156034700 
INJECTION-PUMP ASSEMBLY
6HE1-TMC
9 400 613 300 
1156034701 
INJECTION-PUMP ASSEMBLY
6HE1-TMC
9 400 613 171 
1156034830 
INJECTION-PUMP ASSEMBLY
6SD1-XQB
Back to top