106671-4511 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066714511 3266502160


 

Information injection-pump assembly

ZEXEL 106671-4511 1066714511
MITSUBISHI-HEAV 3266502160 3266502160
106671-4511 INJECTION-PUMP ASSEMBLY
Rating:
69
Buy INJECTION-PUMP ASSEMBLY 106671-4511 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-4511 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-5570
3. GOVERNOR 105447-5671
4. SUPPLY PUMP 105217-1331
5. AUTOM. ADVANCE MECHANIS 105639-2190
6. COUPLING PLATE 105663-0240
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-4170
11. Nozzle and Holder 04234-00090
12. Open Pre:MPa(Kqf/cm2) 29.4{300}
13. NOZZLE-HOLDER 105040-2170
14. NOZZLE 105015-4310
15. NOZZLE SET

Include in #1:

106671-4511 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106671-4511 1066714511
MITSUBISHI-HEAV 3266502160 3266502160


Zexel num
Bosch num
Firm num
Name
106671-4511 
106671-4512 
 
3266502160  MITSUBISHI-HEAV
INJECTION-PUMP ASSEMBLY
S12A * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8130
Bosch type code   EFEP215A
Nozzle   105780-0050
Bosch type code   DN6TD119NP1T
Nozzle holder   105780-2090
Bosch type code   EFEP215
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   2.7 2.65 2.75
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   15.2
Pump speed r/min   1050 1050 1050
Average injection quantity mm3/st.   420.5 411.5 429.5
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
Remarks
Standard point A's rack position same as 106679-2051 in row A
 
Injection quantity adjustment_02
Adjusting point   B
Rack position   6.4+-0.5
Pump speed r/min   250 250 250
Average injection quantity mm3/st.   36.2 33.2 39.2
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   21+-0.5
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   321 321 346
Fixing the lever   *
Timer adjustment
Pump speed r/min   450--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   400
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   700
Advance angle deg.   1.2 0.7 1.7
Timer adjustment_04
Pump speed r/min   1050
Advance angle deg.   3.5 3 4
Timer adjustment_05
Pump speed r/min   -
Advance angle deg.   4 4 4
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 106671-4511
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Idle spring not operating.
----------
K=12
----------

Speed control lever angle

Test data 106671-4511
F:Full speed I:Idle S:Stop
----------

----------
a=28deg+-5deg b=57deg+-5deg c=32deg+-3deg

Stop lever angle

Test data 106671-4511
N:Pump normal S:Stop the pump.
----------

----------
a=35deg+-5deg b=65deg+-5deg

Timing setting

Test data 106671-4511
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(20deg)




Information:

Industrial Rating Definitions
The application examples are listed for reference only. Refer to the specific application information and guidelines within the Technical Marketing Information for exact rating determination.A Rating (Continuous)
* For heavy-duty service when engine is operated at rated load and speed up to 100 percent of the time without interruption or load cycling.* Time at full load up to 100 percent of the duty cycle.* Typical examples are: pipeline pumping, ventilation, and customer specifications.B Rating
* For servicing where power and/or speed are cyclic.* Time at full load not to exceed 80 percent of the duty cycle.* Typical examples are: irrigation where normal pump demand is 85 percent of the duty cycle, oil field mechanical pumping and drilling, and stationary/plant air compressors.C Rating (Intermittent)
* For service where power and/or speed are cyclic* The horsepower and speed capability of the engine can be used for one uninterrupted hour, followed by one hour of operation at or below the A rating.* Time at full load not to exceed 50 percent of the duty cycle.* Typical examples are: agricultural tractors, harvesters and combines, off-highway trucks, fire pump application power, blast hole drills, rock crushers and wood chippers with high torque rise, and oil field hoisting.D Rating
* For service when rated power is required for periodic overloads.* The maximum horsepower and speed capability of the engine can be used for a maximum of 30 uninterrupted minutes, followed by one hour of followed by one hour of C rating operation.* Time at full load not to exceed 10 percent of the duty cycle.* Typical examples are: offshore cranes, runway snow blowers, water well drills, portable air compressors, and fire pump certification power.E Rating
* For service where rated power is required for a short time for initial starting or sudden overload. For emergency service where standard power is unavailable.* The maximum horsepower and speed capability of the engine can be utilized for a maximum of 15 uninterrupted minutes, followed by one hour at C rating operation, or for the duration of the emergency.* Time at full load is not to exceed 5 percent of the duty cycle.* Typical examples are: standby centrifugal water pumps, oil field well servicing, crash trucks, and gas turbine starters.Rating Conditions
Unless otherwise specified, all ratings are based on SAE J1349 standard ambient conditions:* 100 kPa (29.6 inches of Hg) of pressure* 30 percent relative humidity, and* a temperature of 26°C (77°F).Ratings also apply at AS1501, BS5514, DIN6271, and ISO3046/1 standard conditions.Power for diesel engines is based on:* API gravity of 35 at 15°C (60°F),* fuel LHV of 42.780 kJ/g (18390 Btu/lb) at 29°C (84°F), and* fuel density of 838.9 g/L (7.0001 lb/US gal)Ratings are gross output ratings- the total output capability of the engine-equipped with standard accessories. Standard accessories include pumps for lubrication oil, fuel, and jacket water, and magneto as required. The gross output, minus the power required to drive auxiliary components, equals the net power available for the external (flywheel) load. Typical auxiliary components include cooling fans, air compressors,

Have questions with 106671-4511?





Group cross 106671-4511 ZEXEL

Mitsubishi-Heav 

106671-4511  

106671-4512 
 
3266502160 
INJECTION-PUMP ASSEMBLY
S12A
F 019 Z10 521 
3266512160 
INJECTION-PUMP ASSEMBLY
S12A
F 019 Z10 522 
3266522160 
INJECTION-PUMP ASSEMBLY
S12A
F 019 Z10 523 
3266532160 
INJECTION-PUMP ASSEMBLY
S12A
9 400 616 810 
3266542160 
INJECTION-PUMP ASSEMBLY
S12A
Back to top