106671-4212 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066714212 6152711612


 

Information injection-pump assembly

ZEXEL 106671-4212 1066714212
KOMATSU 6152711612 6152711612
106671-4212 INJECTION-PUMP ASSEMBLY
Rating:
11
Buy INJECTION-PUMP ASSEMBLY 106671-4212 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-4212 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106060-5201
3. GOVERNOR 105407-2801
4. SUPPLY PUMP 105217-1490
5. AUTOM. ADVANCE MECHANIS 105635-0190
6. COUPLING PLATE 105663-0400
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105111-4070
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 24.5(250)
13. NOZZLE-HOLDER 105041-7040
14. NOZZLE 105015-5960
15. NOZZLE SET

Include in #1:

106671-4212 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-4212 
 
6152711612  KOMATSU
INJECTION-PUMP ASSEMBLY
SA6D125 * K




Information:

Recommended Coolant Mixture (Maintenance)
Monitor the coolant condition to determine it's proper life. Adding pure antifreeze as a makeup solution for cooling system top-off is an unacceptable practice. It increases the concentration of antifreeze in the cooling system which increases the concentration of dissolved solids and undissolved chemicals in the cooling system. Add antifreeze premixed with acceptable water to the same freeze protection as your cooling system. Use the chart below to assist in determining the concentration of antifreeze to use. Check the coolant solution frequently in cold weather for glycol concentration with the Caterpillar Coolant Tester to ensure adequate freeze protection. There are two testers available. Both testers are identical except temperature scale (one °C; one °F) and give immediate results for antifreeze/coolants that contain ethylene or propylene glycol. Both are available from Caterpillar.Commercial Antifreeze/Water Coolant Mixture
If propylene glycol based antifreeze is used, DO NOT allow concentration greater than a 50/50 antifreeze to water mixture. The measurement of freeze protection must be made with a refractive-type tester rather than a hydrometer-type (which can be used to test ethylene glycol based antifreeze). Use the concentration chart above for proper freeze protection.Liquid supplemental coolant additive must be added, when not using Caterpillar Antifreeze, which contains the proper additive.
Most commercial antifreezes are formulated for gasoline engine applications and will, therefore, have high silicate content. ASTM D4985-89 antifreeze is a low silicate antifreeze and should be used if not using Caterpillar Antifreeze. The percentage of antifreeze and water should be determined by the amount of freeze protection required. Follow the instructions provided by the antifreeze supplier.When using any antifreeze (except Caterpillar Antifreeze) liquid supplemental coolant additive is required at initial fill. Caterpillar or other manufacturer's products can be used as the liquid supplemental coolant additive.Add 2 liter (2 U.S. quart) of liquid supplemental coolant additive, or equivalent, for each 30 liter (8 U.S. gallon) so that the cooling system will have a 3% to 6% concentration of liquid supplemental coolant additive.DO NOT mix Caterpillar liquid Supplemental Coolant Additive (Conditioner) with the other products available; select a cooling system treatment and use it exclusively. If other than Caterpillar products are used as the liquid supplemental coolant additive, follow the manufacturers' recommendation for cooling system treatment and test evaluation.Liquid Supplemental Coolant Additive (Conditioner)
Never use antifreeze/water coolant only, except if Caterpillar Antifreeze is being used. No liquid supplemental coolant additive is needed on initial fill, but is necessary on a maintenance basis.Excessive liquid supplemental coolant additive greater than the maximum recommended 6%, together with concentrations of antifreeze greater than 60% can cause deposits to form and can result in radiator tube blockage, overheating, and/or water pump seal damage.
Caterpillar requires the use of Caterpillar liquid Supplemental Coolant Additive (Conditioner). Caterpillar Antifreeze does NOT require liquid supplemental coolant additive at initial fill, but IS necessary on a maintenance basis.Liquid supplemental coolant additive (conditioner) is necessary to prevent rust, scale, pitting and/or corrosion of engine parts that coolant comes in contact with. A 3 to 6 percent concentration

Have questions with 106671-4212?





Group cross 106671-4212 ZEXEL

Komatsu 

 
6152711281 
INJECTION-PUMP ASSEMBLY
SA6D125
106671-4212  
 
6152711612 
INJECTION-PUMP ASSEMBLY
SA6D125
 
 
INJECTION-PUMP ASSEMBLY
SA6D125
 
6152711521 
INJECTION-PUMP ASSEMBLY
SA6D125
9 400 616 796 
6151711680 
INJECTION-PUMP ASSEMBLY
S6D125
 
 
INJECTION-PUMP ASSEMBLY

Yanmar 

9 400 611 618 
12862751010 
INJECTION-PUMP ASSEMBLY
6GH-UT

Komatsu 

9 400 616 797 
6152711523 
INJECTION-PUMP ASSEMBLY
SA6D125

Daewoo 

 
 
INJECTION-PUMP ASSEMBLY
D1146T
 
 
INJECTION-PUMP ASSEMBLY
D1146T
 
 
INJECTION-PUMP ASSEMBLY
D2366
 
 
INJECTION-PUMP ASSEMBLY
D2366T

Komatsu 

 
6152711310 
INJECTION-PUMP ASSEMBLY
SA6D125
Back to top