106671-3860 ZEXEL 9 400 610 842 BOSCH INJECTION-PUMP ASSEMBLY 9400610842 1066713860 220004600a


 

Information injection-pump assembly

BOSCH 9 400 610 842 9400610842
ZEXEL 106671-3860 1066713860
HINO 220004600A 220004600a
106671-3860 INJECTION-PUMP ASSEMBLY
Rating:
18
Buy INJECTION-PUMP ASSEMBLY 106671-3860 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-3860 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106060-5510
3. GOVERNOR 105488-9500
4. SUPPLY PUMP 105217-1301
5. AUTOM. ADVANCE MECHANIS 105635-0111
6. COUPLING PLATE 105662-0850
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5031
11. Nozzle and Holder 23600-1221A
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-5300
14. NOZZLE 105015-4640
15. NOZZLE SET

Include in #1:

106671-3860 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-3860 
9 400 610 842 
220004600A  HINO
INJECTION-PUMP ASSEMBLY
EK100 * K 14CA PE6P,6PD PE




Information:

You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Before proceeding with Every 1000 Hour maintenance, perform all previous maintenance interval requirements.Engine Protection Devices
Inspect for Proper Operation
Refer to the Service Manual for the procedure. All engine protective devices must be checked and maintained to provide the engine with proper protection if a component malfunction or failure should occur. Check all engine protective devices. Never use the Emergency Shutdown controls for a normal stopping procedure.SR4 Generator and Control Panel (If Equipped)
SR4 Generator
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator: 1. the regulator terminal strip2. the excitation transformer terminal strip (self-excited generator only)Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Clean/Inspect Voltage Regulator
If moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from coastal location sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.* Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.* Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required.Visually inspect the generator and control panel. Check for loose, broken, or damaged wiring or components. The inspection only takes a few minutes and could avert a potential problem that could cause your generator set to fail.Operational Checks
Start the engine. Use the starting procedure found in the SR4 Generators and Control Panels Operation and Maintenance Manual, SEBU6150.The following operational checks include: * generator operation and engine starting* lubricating and fuel systems* overall operationThe checks should take no longer than five minutes to complete. A

Have questions with 106671-3860?





Group cross 106671-3860 ZEXEL

Hino 

 
220004510A 
INJECTION-PUMP ASSEMBLY
EP100
 
220004511A 
INJECTION-PUMP ASSEMBLY
EP100
 
220004512A 
INJECTION-PUMP ASSEMBLY
EP100
9 400 616 782 
220004513A 
INJECTION-PUMP ASSEMBLY
EP100
 
220004540A 
INJECTION-PUMP ASSEMBLY
EK100
 
220004520A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 610 840 
220004521A 
INJECTION-PUMP ASSEMBLY
EK100
 
220202620A 
INJECTION-PUMP ASSEMBLY
EP100T
 
220004590A 
INJECTION-PUMP ASSEMBLY
EK200
 
220004591A 
INJECTION-PUMP ASSEMBLY
EK200
9 400 610 841 
220004560A 
INJECTION-PUMP ASSEMBLY
EK100
106671-3860  
9 400 610 842 
220004600A 
INJECTION-PUMP ASSEMBLY
EK100
 
220004740A 
INJECTION-PUMP ASSEMBLY
EK100
 
220004741A 
INJECTION-PUMP ASSEMBLY
EK100
 
220004790A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 783 
220004810A 
INJECTION-PUMP ASSEMBLY
EK100
Back to top