106671-3591 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1066713591 220003971a


 

Information injection-pump assembly

ZEXEL 106671-3591 1066713591
HINO 220003971A 220003971a
106671-3591 INJECTION-PUMP ASSEMBLY
Rating:
64
Buy INJECTION-PUMP ASSEMBLY 106671-3591 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-3591 
106671-3592 
 
220003971A  HINO
INJECTION-PUMP ASSEMBLY
EK200 * K




Information:

Prior to stopping an engine that is being operated at low loads, run the engine at low idle for 30 seconds before stopping. But, if the engine is being operated at highway speeds and/or high loads, then it should be run at low idle for three minutes to reduce and stabilize internal engine temperature before stopping.To stop the engine, use the method listed that applies to the shutoff system on your truck.1. Turn the key switch to the OFF position, or2. ... pull OUT the manual shutoff control (if equipped), or3. ... push IN and hold the stop button until the engine stops, then release the button.Make sure the shutoff procedure is understood. Refer to the truck manufacturer's instructions for your type of engine shutoff system used. Fill the fuel tank at the end of each day of operation to drive out moist air and to prevent condensation. Do not fill the tank to the top. Fuel expands as it gets warm and may overflow.Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.

Have questions with 106671-3591?





Group cross 106671-3591 ZEXEL

Hino 

 
220201730A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 616 771 
220201731A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201640A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201641A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201790A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201791A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201770A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 610 839 
220201771A 
INJECTION-PUMP ASSEMBLY
EK100
 
 
INJECTION-PUMP ASSEMBLY
EK200
9 400 616 772 
 
INJECTION-PUMP ASSEMBLY
EK200
 
220003890A 
INJECTION-PUMP ASSEMBLY
EK200
 
220003891A 
INJECTION-PUMP ASSEMBLY
EK200
 
220002463A 
INJECTION-PUMP ASSEMBLY
EK200
9 400 616 773 
220002463B 
INJECTION-PUMP ASSEMBLY
EK200
 
220201860A 
INJECTION-PUMP ASSEMBLY
EP100
 
220201861A 
INJECTION-PUMP ASSEMBLY
EP100
 
220000419A 
INJECTION-PUMP ASSEMBLY
YE70
 
220004110A 
INJECTION-PUMP ASSEMBLY
YE70
 
220003970A 
INJECTION-PUMP ASSEMBLY
EK200
106671-3591  

106671-3592 
 
220003971A 
INJECTION-PUMP ASSEMBLY
EK200
9 400 616 774 
220003971B 
INJECTION-PUMP ASSEMBLY
EK200
Back to top