106671-3201 ZEXEL 9 400 610 094 BOSCH INJECTION-PUMP ASSEMBLY 9400610094 1066713201 220001593a


 

Information injection-pump assembly

BOSCH 9 400 610 094 9400610094
ZEXEL 106671-3201 1066713201
HINO 220001593A 220001593a
106671-3201 INJECTION-PUMP ASSEMBLY
Rating:
63
Buy INJECTION-PUMP ASSEMBLY 106671-3201 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-3201 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-5172
3. GOVERNOR 105488-7320
4. SUPPLY PUMP 105217-1301
5. AUTOM. ADVANCE MECHANIS 105635-0041
6. COUPLING PLATE 105662-0500
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4530
11. Nozzle and Holder 23600-1026
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-5300
14. NOZZLE 105015-4120
15. NOZZLE SET

Include in #1:

106671-3201 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
106671-3201 
9 400 610 094 
220001593A  HINO
INJECTION-PUMP ASSEMBLY
EK100 * K




Information:

Air-to-air aftercooling systems are simple, reliable and easy to maintain and provide for one or more benefits.* Improved fuel consumption* Lower emissions* Increased powerOperation of ATAAC
Heated compressed air from the engine turbocharger is conveyed to an air-to-air aftercooler that is positioned in front of the engine radiator. The combined effect of the engine fan and ram air moves cooled air through the system to reduce the turbocharged air temperature before it enters the engine intake manifold.Lower intake air temperature allows more air to enter the cylinder, resulting in more complete fuel combustion and reduced exhaust emissions.Air-to-air aftercoolers can achieve charge air temperatures lower than water-to-air systems for additional efficiency.
To maintain an adequate water pump cavitation temperature for efficient water pump performance in an Air-to-Air aftercooled engine, Caterpillar recommends that the coolant mix contain a minimum of 30% Caterpillar Antifreeze, GM-6038M or equivalent.Only use a greater concentration (above 30%) of antifreeze as needed for anticipated outside temperatures.Ethylene glycol raises the boiling point of water.Do not exceed a coolant mixture of 60% ethylene glycol to water since a concentration above 60% ethylene glycol will reduce the engine's freeze protection and increase the possibility of deposit formation in the cooling system.Dowtherm 209 Full-Fill coolant cannot be substituted for ethylene glycol, due to its inability to raise the water pump cavitation temperature. Dowtherm 209 Full-Fill coolant lowers the boiling point of water.
Air Intake System
Never run the engine without an air cleaner installed or with a damaged air cleaner. Dirt will enter the engine and cause premature wear and damage to engine components.Service the air cleaner at regular intervals as determined by the operating environmental dust conditions. Check the air cleaner service indicator (if equipped) daily.As the air cleaner element becomes plugged, the difference of air pressure between the inlet side (dirty side) and the engine side (clean side) will increase. Service the air cleaners regularly or when the air cleaner service indicator diaphragm enters the red zone or the red piston locks in the visible position.Inspect the air intake hoses, elbows and gaskets for cracks or damage, replace as needed. Check for loose clamps, tighten as needed.Check the precleaner (if equipped) daily for accumulation of dust and debris.The Caterpillar air cleaner element may be cleaned up to six times, but must be replaced annually. The element when cleaned, should be thoroughly checked for rips and tears in the filter material and for gasket damage.Winter Fronts
Caterpillar discourages the use of winter fronts or other air flow restriction devices mounted in front of radiators with air-to-air aftercooled engines. Air flow restriction can cause higher exhaust temperatures, power loss, excessive fan usage, a reduction in fuel economy and possible engine damage.If a winter front must be used, then it should have a permanent circular or diamond-shaped opening directly in line with the fan hub and must have a minimum opening dimension of at least 120 sq. in. (770 sq. cm).A centered opening, versus a side or edge winter front opening is specified to provide sensing

Have questions with 106671-3201?





Group cross 106671-3201 ZEXEL

Hino 

 
220001591A 
INJECTION-PUMP ASSEMBLY
EK100
106671-3201  
9 400 610 094 
220001593A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201121A 
INJECTION-PUMP ASSEMBLY
EK100
 
220201123A 
INJECTION-PUMP ASSEMBLY
EK100
 
220001911A 
INJECTION-PUMP ASSEMBLY
EK100
 
220001912A 
INJECTION-PUMP ASSEMBLY
EK100
 
220002111A 
INJECTION-PUMP ASSEMBLY
EK100
 
220002112A 
INJECTION-PUMP ASSEMBLY
EK100
 
220001491A 
INJECTION-PUMP ASSEMBLY
EK100
 
220001493A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 610 084 
220001494A 
INJECTION-PUMP ASSEMBLY
EK100
 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 616 767 
220001494B 
INJECTION-PUMP ASSEMBLY
EK100
9 400 619 432 
220001495A 
INJECTION-PUMP ASSEMBLY
EK100
 
220002170A 
INJECTION-PUMP ASSEMBLY
EK100
 
220002180A 
INJECTION-PUMP ASSEMBLY
 
220002580A 
INJECTION-PUMP ASSEMBLY
EK200
 
220002581A 
INJECTION-PUMP ASSEMBLY
EK200
 
220002171A 
INJECTION-PUMP ASSEMBLY
 
220002173A 
INJECTION-PUMP ASSEMBLY
EK100
9 400 610 110 
220002175A 
INJECTION-PUMP ASSEMBLY
EK100
 
220002350A 
INJECTION-PUMP ASSEMBLY
EK100
 
220002351A 
INJECTION-PUMP ASSEMBLY
EK100
Back to top