106671-2620 ZEXEL 9 400 616 755 BOSCH INJECTION-PUMP ASSEMBLY 9400616755 1066712620 me059578


 

Information injection-pump assembly

BOSCH 9 400 616 755 9400616755
ZEXEL 106671-2620 1066712620
MITSUBISHI ME059578 me059578
106671-2620 INJECTION-PUMP ASSEMBLY
Rating:
84
Buy INJECTION-PUMP ASSEMBLY 106671-2620 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-2620 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-7131
3. GOVERNOR 105407-1510
4. SUPPLY PUMP 105237-1270
5. AUTOM. ADVANCE MECHANIS 105636-0910
6. COUPLING PLATE 105662-0710
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5820
11. Nozzle and Holder ME056329
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/21.6{220}
13. NOZZLE-HOLDER 105031-4530
14. NOZZLE 105015-5390
15. NOZZLE SET

Include in #1:

106671-2620 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 616 755 9400616755
ZEXEL 106671-2620 1066712620
MITSUBISHI ME059578 me059578


Zexel num
Bosch num
Firm num
Name
106671-2620 
106671-2930 
9 400 616 755 
ME059578  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D22MTK * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-4620
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   11.5
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   142.4 139.4 145.4
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   5.5+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   16 13.4 18.6
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Timer adjustment
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   -
Advance angle deg.   2 2 2
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 106671-2620
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT: RAL (3)Setting at shipping (4)Idle sub spring setting: L1.
----------
K=5 RAL=12.5+0.2mm L1=5.5-0.5mm
----------

Speed control lever angle

Test data 106671-2620
F:Full speed I:Idle S:Stop (1)At shipping
----------

----------
a=30deg+-5deg b=32deg+-3deg c=7deg+-5deg d=(2deg)

Stop lever angle

Test data 106671-2620
N:Pump normal S:Stop the pump.
----------

----------
a=20deg+-5deg b=46deg+-5deg

Timing setting

Test data 106671-2620
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(7deg)




Information:

Appendix
Configuration Information
Table 7
Over-Temp    
Inlet Over-Temperature Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output function     ON only during alarm    
    Assert Alarm     Above
650 °C (1202 °F)    
    Hysteresis    
20 °C (68 °F)    
    Upon Over Temperature extend alarm for 60 seconds    
Table 8
Over-Pres    
Over-Pressure Warning        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     ON only during alarm    
    Assert Alarm when the measured pressure exceeds 7" of Hg for 5% of the time during a 60 min measurement interval    
Over-Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 2    
    Output Function     Latched ON upon alarm    
    Assert alarm when the measured pressure exceeds 8" of Hg for 5% of the time during a 60 min measurement interval    
Table 9
TC-Fail (1)    
Open Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if measured temperature is above
1000 °C (1832 °F)    
Shorted Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if pressure is greater than 1" of Hg for 10 min and measured temperature does not exceed
120 °C (248 °F)    
( 1 ) Output selection applies to both open and shorted alarms
Table 10
Pressure Sensor Fail    
No Change Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Outputs During Alarm     Output 1    
    Output Function     Latched ON upon Alarm    
    Assert alarm if exhaust temperature is above
250 °C (482 °F) for 10 min and the pressure doesn't change by at least 0.25" of Hg    
Negative Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     Latched ON during alarm    
    Assert Alarm if temperature is above
200 °C (392 °F) for 10 min and the pressure is less than −1" of

Have questions with 106671-2620?





Group cross 106671-2620 ZEXEL

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
6D22T4
 
ME056291 
INJECTION-PUMP ASSEMBLY
6D22T4
 
 
INJECTION-PUMP ASSEMBLY
6D22T2
 
ME056298 
INJECTION-PUMP ASSEMBLY
6D22T2
106671-2620  

106671-2930 
9 400 616 755 
ME059578 
INJECTION-PUMP ASSEMBLY
6D22MTK
 
ME056308 
INJECTION-PUMP ASSEMBLY
6D22
9 400 616 756 
ME056309 
INJECTION-PUMP ASSEMBLY
6D22

Mitsubishi-Heav 

 
3626500350 
INJECTION-PUMP ASSEMBLY
S6B
 
3626510350 
INJECTION-PUMP ASSEMBLY
S6B
 
3256510050 
INJECTION-PUMP ASSEMBLY
S6A

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
6D22T3
 
ME056318 
INJECTION-PUMP ASSEMBLY
6D22T3

Mitsubishi-Heav 

 
3626500180 
INJECTION-PUMP ASSEMBLY
S6B
 
3626510180 
INJECTION-PUMP ASSEMBLY
S6B
 
3626520180 
INJECTION-PUMP ASSEMBLY
S6B
 
3626520181 
INJECTION-PUMP ASSEMBLY
S6B
9 400 610 323 
3626520182 
INJECTION-PUMP ASSEMBLY
S6B
 
3626530180 
INJECTION-PUMP ASSEMBLY
S6B
 
3626540180 
INJECTION-PUMP ASSEMBLY
S6B
9 400 616 757 
3626530170 
INJECTION-PUMP ASSEMBLY
S6B

Mitsubishi 

 
ME056324 
INJECTION-PUMP ASSEMBLY
6D22
Back to top