106671-1761 ZEXEL 9 400 619 857 BOSCH INJECTION-PUMP ASSEMBLY 9400619857 1066711761 1156027852


 

Information injection-pump assembly

BOSCH 9 400 619 857 9400619857
ZEXEL 106671-1761 1066711761
ISUZU 1156027852 1156027852
106671-1761 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 106671-1761 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-1761 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-7360
3. GOVERNOR 105407-4870
4. SUPPLY PUMP 105207-1480
5. AUTOM. ADVANCE MECHANIS 105635-0380
6. COUPLING PLATE 105662-0990
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-6672
11. Nozzle and Holder 1-15300-289-2
12. Open Pre:MPa(Kqf/cm2) 19.6
13. NOZZLE-HOLDER 105030-3201
14. NOZZLE 105015-9071
15. NOZZLE SET

Include in #1:

106671-1761 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 619 857 9400619857
ZEXEL 106671-1761 1066711761
ISUZU 1156027852 1156027852


Zexel num
Bosch num
Firm num
Name
106671-1761 
106671-1762 
9 400 619 857 
1156027852  ISUZU
INJECTION-PUMP ASSEMBLY
6SD1-T * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.7 3.67 3.73
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   8
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   134.3 132.3 136.3
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   5.2+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   14.5 11.3 17.7
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Timer adjustment
Pump speed r/min   900--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   850
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1000
Advance angle deg.   1 0.5 1.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106671-1761
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Set idle sub-spring (3)Main spring setting
----------
K=16
----------

Speed control lever angle

Test data 106671-1761
F:Full speed I:Idle S:Stop (1)Seal at shipping.
----------

----------
a=8deg+-5deg b=22deg+-5deg c=32deg+-3deg

Stop lever angle

Test data 106671-1761
N:Pump normal S:Stop the pump.
----------

----------
a=8.5deg+-5deg b=53deg+-5deg

Timing setting

Test data 106671-1761
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=18deg
----------
a=(50deg)




Information:

Start By:a. remove governor**See Disassemble Governor story
Keep all parts clean from contaminants. Contaminants put into the system may cause rapid wear and shortened component life.
1. Remove the bolts and the plate from the side of the fuel injection pump housing. 2. Install tool (A) in the fuel injection pump housing. Move the rack until tool (A) can be installed to hold the rack in the center position to remove the fuel injection pumps.3. Use tool (B) to remove bushing (1).4. Remove the O-ring seal from the fuel injection pump housing. 5. Install tool (C) on the bonnet and remove the fuel injection pump. 6. Remove spacer (2). Keep the spacers (2) from the fuel injection pumps together with identification as to their location in the pump housing.7. Perform steps 3 through 6 to remove the other fuel injection pumps. The following steps are to install the fuel injection pumps.8. Install spacer (2).9. Install tool (A). Move the rack until tool (A) can be installed to hold the rack in the center position. The rack must be in the center position to install the fuel injection pumps.10. Turn camshaft until the lobe of the camshaft is down for the pump to be installed.11. Install tool (C) on the bonnet on the fuel injection pump.12. Install the fuel injection pump in the pump housing with saw cut slot in the gear in alignment with the small pin and groove in the barrel in alignment with dowel in the pump housing.13. Put clean oil on O-ring seal and install it in the fuel injection pump housing.14. Install the bushing by hand until the bushing is even with the top of the housing. If the bushing can not be installed this far by hand, remove it. Remove the fuel injection pump ad put the pump in alignment again and install the bushing again.15. Install tool (B) on the bushing and tighten the bushing to a torque of 190 14 N m (140 10 lb ft).16. Install tooling (D) to measure total rack travel. Correct rack travel is 15.7 mm (.618 in). A smaller measurement is an indication of improper fuel injection pump installation.17. Perform Steps 1 through 9 to install the other fuel pumps18. Install the cover and gasket on the fuel injection pump housing.End By:a. install governor**See Assemble Governor storyDisassemble And Assemble Fuel Injection Pumps
Start By:a. remove fuel injection pumps
When the injection pumps are disassembled, handle the parts carefully. Do not damage the surfaces of the plungers, barrels and bonnets. Any scratches will cause leakage inside the fuel injection pump. The plunger and barrel for each pump are made as a set. Do not intermix the plunger of one pump in the barrel with another pump. If one part is worn, install a complete new pump assembly. Be careful when placing the plunger into the bore of the barrel.
1. Pull plunger (1) and washer (5) out of barrel (3) and spring (2).
Do not remove the gear from the plunger.

Have questions with 106671-1761?





Group cross 106671-1761 ZEXEL

Isuzu 

 
1156027851 
INJECTION-PUMP ASSEMBLY
6SD1-T
106671-1761  

106671-1762 
9 400 619 857 
1156027852 
INJECTION-PUMP ASSEMBLY
6SD1-T
 
1156027853 
INJECTION-PUMP ASSEMBLY
6SD1-T
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
1156027855 
INJECTION-PUMP ASSEMBLY
6SD1-T
9 400 610 366 
1156032620 
INJECTION-PUMP ASSEMBLY
6SD1-T
Back to top