106671-1671 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066711671 1156026111


 

Information injection-pump assembly

ZEXEL 106671-1671 1066711671
ISUZU 1156026111 1156026111
106671-1671 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 106671-1671 zexel genuine, new aftermarket engine parts with delivery

Service parts 106671-1671 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-7120
3. GOVERNOR 105952-0720
4. SUPPLY PUMP 105237-4060
5. AUTOM. ADVANCE MECHANIS 105691-3480
6. COUPLING PLATE 105663-0610
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-6073
11. Nozzle and Holder 1-15300-217-3
12. Open Pre:MPa(Kqf/cm2) 22.1{225}
13. NOZZLE-HOLDER 105030-3251
14. NOZZLE 105015-8192
15. NOZZLE SET

Include in #1:

106671-1671 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106671-1671 1066711671
ISUZU 1156026111 1156026111


Zexel num
Bosch num
Firm num
Name
106671-1671 
106671-1672 
 
1156026111  ISUZU
INJECTION-PUMP ASSEMBLY
6SD1-TC2 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
RED3 control unit part number   407910-2 470
RED3 rack sensor specifications mm   15
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.7 3.67 3.73
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Rack position   (12.7)
Vist V   1.46 1.46 1.46
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   170.3 168.3 172.3
Max. variation between cylinders %   0 -3 3
Basic   *
Injection quantity adjustment_02
Rack position   (7)
Vist V   2.6 2.5 2.7
Pump speed r/min   240 240 240
Average injection quantity mm3/st.   11 7.8 14.2
Max. variation between cylinders %   0 -13 13
Injection quantity adjustment_03
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   132 112 132
Remarks
Set the rack limit, measure rack position and Vista.
 

Test data Ex:

Governor adjustment

Test data 106671-1671
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N2=800r/min C2=(5.5deg) t1=2--sec. t2=2--sec.
----------
N1=800++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=5.5+-0.3deg R01=0/4load R02=4/4load

0000000901

Test data 106671-1671
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=8deg
----------
a=(40deg)

Stop lever angle

Test data 106671-1671
(Rs) rack sensor specifications (C/U) control unit part number (V) Rack sensor output voltage (R) Rack position (mm) 1. Confirming governor output characteristics (rack 15 mm, span 6 mm) (1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------

----------




Information:

Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must be at least 75% (1.225 Sp. Gr.) fully charged and held tightly in place. The battery holder must not put too much stress on the battery.2. Cables between the battery, starter and engine ground must be the correct size. Wires and cables must be free of corrosion and have cable support clamps to prevent stress on battery connections (terminals).3. Leads, junctions, switches and panel instruments that have direct relation to the charging circuit must give correct circuit control.4. Inspect the drive components for the charging unit to be sure they are free of grease and oil and have the ability to operate the charging unit.Delco-Remy Alternator; Pulley Nut Tightening
Tighten nut that holds the pulley to a torque of 100 7 N m (75 5 lb ft) with the tools shown.
Tools To Tighten Alternator Pulley Nut
(1) 8T9293 Torque Wrench. (2) 8S1588 Adapter (1/2" female to 3/8" male). (3) 2P8267 Socket Assembly. (4) 8H8517 Combination Wrench (1 1/8"). (5) 8T5314 Socket.Alternator Regulator Adjustment - (Delco-Remy)
When an alternator is charging the battery too much or not enough, an adjustment can be made to the charging rate of the alternator. Make reference to the Specifications section to find all testing specifications for the alternators and regulators.3T6352 Alternator 24V 35A (Delco-Remy Number 1117647)
3T6352 AlternatorNo adjustment can be made to change the rate of charge on the alternator regulator. If rate of charge is not correct, a replacement of the regulator is necessary.7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001)
7N9720 AlternatorThe solid state regulator used with the Bosch Alternator is totally enclosed and non-adjustable. If the rate of charge is not correct a replacement of the regulator is necessary.9G4574 24V 35A (Nippondenso Number 100211-0860)
9G4574 AlternatorNo adjustment can be made to change the rate of charge on the alternator regulator. If rate of charge is not correct, a replacement of the regulator is necessary.Starting System
Use the multimeter in the DCV range to find starting system components which do not function.Move the start control switch to activate the starter solenoid. Starter solenoid operation can be heard as the pinion

Have questions with 106671-1671?





Group cross 106671-1671 ZEXEL

Isuzu 

 
1156026110 
INJECTION-PUMP ASSEMBLY
6SD1-TC2
106671-1671  

106671-1672 
 
1156026111 
INJECTION-PUMP ASSEMBLY
6SD1-TC2
 
1156026112 
INJECTION-PUMP ASSEMBLY
6SD1-TC2
 
1156026113 
INJECTION-PUMP ASSEMBLY
6SD1-TC2
9 400 616 722 
1156026114 
INJECTION-PUMP ASSEMBLY
6SD1-TC2
Back to top