Information injection-pump assembly
BOSCH
9 460 610 081
9460610081
ZEXEL
104760-2001
1047602001
NISSAN
16700V0700
16700v0700

Rating:
Cross reference number
BOSCH
9 460 610 081
9460610081
ZEXEL
104760-2001
1047602001
NISSAN
16700V0700
16700v0700
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
(Note)
For Japan: year/month/day (change sequence) 1983/09/13 (1)
For Japan: year/month/day (change sequence) 1983/09/13 (1)
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
35.1
34.6
35.6
Difference in delivery
mm3/st.
2.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
11.7
8.7
14.7
Injection timing adjustment_03
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
30.8
28.8
32.8
Injection timing adjustment_04
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
35.1
34.6
35.6
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
30.5
28.5
32.5
Injection timing adjustment_06
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
34.3
33.8
34.8
Difference in delivery
mm3/st.
2.5
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_07
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
10
6.5
13.5
Remarks
For Japan
For Japan
Injection timing adjustment_08
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
30.4
28.4
32.4
Remarks
For Japan
For Japan
Injection timing adjustment_09
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
34.3
33.3
35.3
Remarks
For Japan
For Japan
Injection timing adjustment_10
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
29
27
31
Remarks
For Japan
For Japan
Injection quantity adjustment
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
11.7
8.7
14.7
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2800
2800
2800
Average injection quantity
mm3/st.
5
Injection quantity adjustment_03
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
10
7
13
Basic
*
Remarks
For Japan
For Japan
Injection quantity adjustment_04
Pump speed
r/min
2800
2800
2800
Average injection quantity
mm3/st.
5
Remarks
For Japan
For Japan
Governor adjustment
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
8.6
7.1
10.1
Difference in delivery
mm3/st.
3
Basic
*
Governor adjustment_02
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
8.6
7.1
10.1
Governor adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
4
Governor adjustment_04
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
8.2
6.7
9.7
Difference in delivery
mm3/st.
3
Basic
*
Remarks
For Japan
For Japan
Governor adjustment_05
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
8.2
6.2
10.2
Remarks
For Japan
For Japan
Governor adjustment_06
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
4
Remarks
For Japan
For Japan
Boost compensator adjustment
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
18
13
23
Remarks
From idle
From idle
Boost compensator adjustment_02
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
17
12
22
Remarks
For Japan: from idle
For Japan: from idle
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50
50
Basic
*
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
47
47
Basic
*
Remarks
For Japan
For Japan
Speed control lever angle
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
Speed control lever angle_02
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan: Magnet OFF
For Japan: Magnet OFF
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
420
288
552
_02
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
450
318
582
Remarks
For Japan
For Japan
Stop lever angle
Pump speed
r/min
1800
1800
1800
Pressure
kPa
608
579
637
Pressure
kgf/cm2
6.2
5.9
6.5
Basic
*
Stop lever angle_02
Pump speed
r/min
800
800
800
Pressure
kPa
382.5
353
412
Pressure
kgf/cm2
3.9
3.6
4.2
Stop lever angle_03
Pump speed
r/min
1800
1800
1800
Pressure
kPa
608
579
637
Pressure
kgf/cm2
6.2
5.9
6.5
Stop lever angle_04
Pump speed
r/min
2500
2500
2500
Pressure
kPa
755.5
726
785
Pressure
kgf/cm2
7.7
7.4
8
Stop lever angle_05
Pump speed
r/min
1800
1800
1800
Pressure
kPa
588.5
559
618
Pressure
kgf/cm2
6
5.7
6.3
Basic
*
Remarks
For Japan
For Japan
Stop lever angle_06
Pump speed
r/min
800
800
800
Pressure
kPa
363
324
402
Pressure
kgf/cm2
3.7
3.3
4.1
Remarks
For Japan
For Japan
Stop lever angle_07
Pump speed
r/min
1800
1800
1800
Pressure
kPa
588.5
549
628
Pressure
kgf/cm2
6
5.6
6.4
Remarks
For Japan
For Japan
Stop lever angle_08
Pump speed
r/min
2500
2500
2500
Pressure
kPa
735.5
696
775
Pressure
kgf/cm2
7.5
7.1
7.9
Remarks
For Japan
For Japan
0000001101
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.8
2.5
3.1
Basic
*
_02
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.8
2.5
3.1
_03
Pump speed
r/min
1800
1800
1800
Timer stroke
mm
5.5
4.9
6.1
_04
Pump speed
r/min
2300
2300
2300
Timer stroke
mm
8.15
7.7
8.6
_05
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.7
2.4
3
Basic
*
Remarks
For Japan
For Japan
_06
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.7
2.3
3.1
Remarks
For Japan
For Japan
_07
Pump speed
r/min
1800
1800
1800
Timer stroke
mm
5.4
4.8
6
Remarks
For Japan
For Japan
_08
Pump speed
r/min
2300
2300
2300
Timer stroke
mm
8.15
7.7
8.6
Remarks
For Japan
For Japan
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
6.64
6.54
6.74
MS dimension
mm
1.8
1.7
1.9
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
44
39
49
Control lever angle gamma
deg.
11
10.5
11.5
Information:
AUGUST 2011
INFORMATION RELEASE MEMO
Reman
PELJ1306 ?2011 Caterpillar REMAN DIESEL PARTICULATE FILTERS FOR MACHINE APPLICATIONS
To provide our customers with cost effective service options to support their Tier 4 emissions engines, Cat Reman has released a Reman version of the diesel particulate filters (DPF) used on many Tier 4 Cat? machines. The DPF traps both soot and ash. Soot is removed through a regeneration process outlined in the machines operation and maintenance manual. Ash that accumulates from engine oil is removed through a cleaning procedure that requires removal of the DPF from the machine. The cleaning procedure requires the DPF to be removed from the machine. Special Instruction REHS5045 outlines the three approved processes for performing the required Diesel Particulate Filter (DPF) maintenance on Tier 4 products equipped with a DPF.
Replacement of the existing DPF with a new Cat DPF
Replacement of the existing DPF with a remanufactured Cat DPF
Removal of the existing DPF and having the DPF cleaned by a Cat approved cleaning device.
The Reman DPFs listed below are available to support these maintenance requirements:
Core Acceptance
After gaining some experience with the previously released DPFs used for on-highway engines and to support the launch of these additional machine DPFs, we have changed some of the inspection criteria and issued a revision to SELD0292. SELD0292-02 Caterpillar Diesel Particulate Filter (DPF) is the current Core Acceptance Criteria (CAC). It is critical to avoid non-operational damage that can decrease the value of the cores. Encourage service technicians to handle and package the cores with care so they will be more likely to be eligible for the full core refunds. Please always refer to the most current version at catreman.cat.com/core to view the latest requirements. The acceptability inspection for these is a simple visual inspection based on the following guidelines:
Warranty
All Reman products carry the same warranty as new parts. Please consult the appropriate warranty statement for your area.
Core Management
Please refer to the Cat Core Management Information System (CMIS 2) related to the parts information application that describes all Reman part/Core Acceptability Family (CAF) and other related information. Also refer to other CMIS 2 inquiry applications such as: Dealer Customer Profile, Inspection Reason Codes, Inspection Line Inquiry, Dealer Add Charges, Dealer Entitlement Activity, Dealer CCR Inquiry, Dealer CCR Entry, Dealer Shipment Processing, Dealer Process Packaging Grief and Reporting. This information is available to all dealers worldwide that have been converted to CMIS 2.
Please go to the Reman web site https://catreman.cat.com for the latest policy and procedural updates that are available to all dealers worldwide explaining policy and procedural information such as Policy and Core Management SELD0122 -10, "Core Management Systems and Operations Procedures SELD0040-14, "Reman Core Return Packaging Instructions And Guidelines SELD0300-00 and "Shipping Instructions" SELD0039-14.
If you have any questions regarding Reman Core Management or Core Management Systems (CMIS2),