104741-8060 ZEXEL 9 460 614 936 BOSCH INJECTION-PUMP ASSEMBLY 9460614936 1047418060 32c6500270


 

Information injection-pump assembly

BOSCH 9 460 614 936 9460614936
ZEXEL 104741-8060 1047418060
MITSUBISHI-HEAV 32C6500270 32c6500270
104741-8060 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 104741-8060 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

BOSCH 9 460 614 936 9460614936
ZEXEL 104741-8060 1047418060
MITSUBISHI-HEAV 32C6500270 32c6500270


Zexel num
Bosch num
Firm num
Name
104741-8060 
104741-8061 
9 460 614 936 
32C6500270  MITSUBISHI-HEAV
INJECTION-PUMP ASSEMBLY
S4Q2 * K 11CJ VE4 VE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   47.1 46.6 47.6
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   43.5 39.5 47.5
Oil temperature degC   48 46 50
Injection timing adjustment_03
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   48.6 44.6 52.6
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   47.1 46.1 48.1
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   1350 1350 1350
Average injection quantity mm3/st.   9.9 7.9 11.9
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   50 48 52
Injection quantity adjustment_02
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   3
Oil temperature degC   50 48 52
Injection quantity adjustment_03
Pump speed r/min   1350 1350 1350
Average injection quantity mm3/st.   9.9 6.4 13.4
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   50 48 52
Governor adjustment
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   11.1 9.1 13.1
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   11.1 8.6 13.6
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   64.8 59.8 69.8
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   64.8 59.8 69.8
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1000 1000 1000
Overflow quantity cm3/min   460 330 590
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1000 1000 1000
Pressure kPa   618 589 647
Pressure kgf/cm2   6.3 6 6.6
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_02
Pump speed r/min   500 500 500
Pressure kPa   500 451 549
Pressure kgf/cm2   5.1 4.6 5.6
Oil temperature degC   48 46 50
Stop lever angle_03
Pump speed r/min   800 800 800
Pressure kPa   579 530 628
Pressure kgf/cm2   5.9 5.4 6.4
Oil temperature degC   50 48 52
Stop lever angle_04
Pump speed r/min   1000 1000 1000
Pressure kPa   618 579 657
Pressure kgf/cm2   6.3 5.9 6.7
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_05
Pump speed r/min   1200 1200 1200
Pressure kPa   667 618 716
Pressure kgf/cm2   6.8 6.3 7.3
Oil temperature degC   50 48 52
0000001101
Pump speed r/min   1000 1000 1000
Timer stroke mm   2.1 1.9 2.3
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   500 500 500
Timer stroke mm   0.7
Oil temperature degC   48 46 50
_03
Pump speed r/min   800 800 800
Timer stroke mm   1.5 0.9 2.1
Oil temperature degC   50 48 52
_04
Pump speed r/min   1000 1000 1000
Timer stroke mm   2.1 1.7 2.5
Basic   *
Oil temperature degC   50 48 52
_05
Pump speed r/min   1200 1200 1200
Timer stroke mm   2.8 2.2 3.4
Oil temperature degC   50 48 52
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   35.5 35 36
Timer stroke TA mm   2 1.8 2.2
Timer stroke variation dT mm   0.8 0.8 0.8
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   47.1 46.1 48.1
Timer stroke TA mm   2.8 2.2 3.4
Oil temperature degC   50 48 52
_03
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   35.5 34.5 36.5
Timer stroke TA mm   2 1.6 2.4
Timer stroke variation dT mm   0.8 0.8 0.8
Basic   *
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   2 1.9 2.1
Pre-stroke mm   0.1 0.08 0.12
Control lever angle alpha deg.   25 21 29
Control lever angle beta deg.   27 22 32

Test data Ex:

0000001801 STARTING I/Q ADJUSTMENT

Test data 104741-8060
Starting Q decrease lever adjustment Adjust using the screw (A) so that the standards are satisfied, then fix using the nut (B) (Torque to T after adjustment) Screw protrusion: L (C) = Cap (D) = Stop lever
----------
L=7.4~11.1mm T=6~9N-m(0.6~0.9kgf-m)
----------
L=7.4~11.1mm T=6~9N-m(0.6~0.9kgf-m) SW=SW10




Information:

Cold Weather Battery Maintenance
General Maintenance
1. After adding make-up water, charge the battery. The added water could dilute the electrolyte enough without charging to cause freezing and permanent damage to the battery.2. Keep the batteries fully charged either by operating the charging system or by using a battery charger.3. Keep the battery warm when not in use. In an unheated area, the heat from a lighted electric bulb is usually sufficient.
Use only a shop cord with a heavy wire guard around the light bulb.
Do not lay a lighted bulb directly on a battery case; the heat at point of contact could melt the battery case.Do not lay cloth or flammable material in contact with a lighted bulb; charring and/or fire could result.4. Use starting aids as instructed for starting the engine.5. Use booster batteries as required. Connect the batteries as instructed below.6. If a battery is not going to be used for a period of time, be sure the battery is fully charged while stored. Use a battery hydrometer to check the specific gravity of each cell, and use a battery charger to keep the battery charged. See the instructions below.Voltage Test (After Load)
A load test should be made on a battery that discharges very rapidly when in use. To do this apply a resistance of three times the ampere/hour rating of the battery across the battery main terminals. Allow the resistance to discharge the the battery for 15 seconds and immediately test the battery voltage. A 6 volt battery in good condition will test 4.5 volts; a 12 volt battery in good condition will test 9 volts and a 24 volt battery will test 18 volts.Starter
No periodic service is indicated for the electric starter brushes between general reconditioning periods. The brushes should only be inspected after removal of the starter from the engine and removal of the commutator end bearing frame. The electric starter commutator end and drive end bearings are equipped with wicks for lubrication purposes. The wicks should be saturated with oil whenever the electric starter is removed or disassembled.It is suggested that cleaning and reconditioning be entrusted to your authorized dealer.Pinion Clearance Adjustment
Whenever the solenoid is installed, the pinion clearance should be adjusted. The adjustment should be made with the starting motor removed.Bench test and adjust the pinion clearance at installation of solenoid as follows:
CIRCUIT FOR CHECKING AND ADJUSTING PINION CLEARANCE1. Install the solenoid without connector from the MOTOR terminal on solenoid to the motor.2. Connect a battery, of the same voltage as the solenoid, to the terminal marked SW.3. Connect the other side of battery to ground terminal or to solenoid frame.
ADJUSTING PINION CLEARANCE4. MOMENTARILY flash a jumper wire from the solenoid terminal marked MOTOR to the frame or ground terminal. The pinion will shift into cranking position and will remain there until the battery is disconnected.5. Push pinion towards commutator end to eliminate free movement.6. Pinion clearance should be .36 in. (9.14 mm).7. Adjust clearance by removing plug and turning shaft nut.
ADJUSTING PINION

Have questions with 104741-8060?





Group cross 104741-8060 ZEXEL

Mitsubishi-Heav 

9 460 614 842 
32C6500250 
INJECTION-PUMP ASSEMBLY
S4Q2
9 460 614 862 
32C6510250 
INJECTION-PUMP ASSEMBLY
S4Q2
9 460 614 820 
32C6500260 
INJECTION-PUMP ASSEMBLY
S4Q2
9 460 614 825 
32A6500390 
INJECTION-PUMP ASSEMBLY
S4S
9 460 614 857 
32A6500380 
INJECTION-PUMP ASSEMBLY
S4S
F 01G 09W 0G8 
32A6510380 
INJECTION-PUMP ASSEMBLY
S4S
104741-8060  

104741-8061 
9 460 614 936 
32C6500270 
INJECTION-PUMP ASSEMBLY
S4Q2
9 460 614 943 
32C6510270 
INJECTION-PUMP ASSEMBLY
S4Q2
9 460 615 038 
32C6500280 
INJECTION-PUMP ASSEMBLY
S4Q
F 01G 09W 0E3 
32C6500310 
INJECTION-PUMP ASSEMBLY
S4Q2
F 01G 09W 0DX 
32C6510310 
INJECTION-PUMP ASSEMBLY
S4Q2
9 460 615 090 
32C6500330 
INJECTION-PUMP ASSEMBLY
S4Q2
F 01G 09W 0DY 
32C6500331 
INJECTION-PUMP ASSEMBLY
S4Q2
Back to top