Information injection-pump assembly
ZEXEL
104741-1430
1047411430
ISUZU
8944527850
8944527850

Rating:
Cross reference number
ZEXEL
104741-1430
1047411430
ISUZU
8944527850
8944527850
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
1150
1150
1150
Average injection quantity
mm3/st.
40.8
40.3
41.3
Difference in delivery
mm3/st.
3.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
24.2
20.7
27.7
Injection timing adjustment_03
Pump speed
r/min
2000
2000
2000
Average injection quantity
mm3/st.
40.3
36.8
43.8
Injection timing adjustment_04
Pump speed
r/min
1900
1900
1900
Average injection quantity
mm3/st.
41.3
37.8
44.8
Injection timing adjustment_05
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
40.7
38.2
43.2
Injection timing adjustment_06
Pump speed
r/min
1150
1150
1150
Average injection quantity
mm3/st.
40.8
39.8
41.8
Injection timing adjustment_07
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
35.8
33.3
38.3
Injection timing adjustment_08
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
36.4
32.4
40.4
Injection quantity adjustment
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
24.2
21.2
27.2
Difference in delivery
mm3/st.
3.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
6
Governor adjustment
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
6
4
8
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
6
4
8
Governor adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
80
60
100
Basic
*
Speed control lever angle
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1600
1600
1600
Overflow quantity
cm3/min
429
300
558
Stop lever angle
Pump speed
r/min
1600
1600
1600
Pressure
kPa
490.5
471
510
Pressure
kgf/cm2
5
4.8
5.2
Basic
*
Stop lever angle_02
Pump speed
r/min
1600
1600
1600
Pressure
kPa
490.5
471
510
Pressure
kgf/cm2
5
4.8
5.2
Stop lever angle_03
Pump speed
r/min
2000
2000
2000
Pressure
kPa
617.5
588
647
Pressure
kgf/cm2
6.3
6
6.6
Stop lever angle_04
Pump speed
r/min
1020
1020
1020
Pressure
kPa
333.5
304
363
Pressure
kgf/cm2
3.4
3.1
3.7
0000001101
Pump speed
r/min
1600
1600
1600
Timer stroke
mm
4.8
4.6
5
Basic
*
_02
Pump speed
r/min
1600
1600
1600
Timer stroke
mm
4.8
4.5
5.1
_03
Pump speed
r/min
2000
2000
2000
Timer stroke
mm
7.8
7.4
8.2
_04
Pump speed
r/min
1020
1020
1020
Timer stroke
mm
0.55
0
1.1
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
1
0.9
1.1
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42
Information:
Introduction
The problem identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
There are reports of C4.4 DEF pumps failing in cold weather, below approximately −29° C (−20° F) , but the pumps are "No Fault Found" when returned for evaluation.Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Ensure that the engine is stopped before any servicing or repair is performed. The Diesel Exhaust Fluid (DEF) system must have completed a proper shutdown. Service on the DEF pump prior to completion of a proper shutdown can result in DEF spray and spillage.
Do not turn off the battery disconnect switch until the indicator lamp has turned off. If the switch is turned off when the indicator lamp is illuminated, the Diesel Exhaust Fluid (DEF) system may not shut down properly. If the DEF system does not shut down properly, DEF could freeze and damage the pump and lines.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Cat Dealer Service Tool Catalog" or refer to Special Publication, PECJ0003, "Cat Shop Supplies and Tools Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Note: Clean water should be used to wash spilled DEF off machine components and surfaces.Note: Wear gloves when handling the DEF filter.When troubleshooting the DEF pump during cold weather, the Compensator Plug within the DEF pump is designed to prevent pump operation if the DEF within the pump is frozen. The Compensator Plug will temporarily be pushed to the OFF position by the frozen DEF. The pump should return to the ON position once the DEF thaws.
Illustration 1 g06278274
(1) Protective cover
Remove protective cover (1).
Illustration 2 g06278289
(2) DEF filter cap
Use a suitable tool to remove DEF filter cap (2).
Illustration 3 g06278325
(3) Compensator
With the filter installed in the DEF pump, carefully remove compensator (3).
Illustration 4 g06278356
(A) 38 mm (1.5 inch)
(B) 97 mm (3.8 inch)
Inspect the compensator.If frozen DEF within the pump is identified as the root cause of the issue, submit a SIMSi report, complete with TIB number M0094916, CPI number 411775 and submit through the CPI feedback tool within the SIMSi.
The problem identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
There are reports of C4.4 DEF pumps failing in cold weather, below approximately −29° C (−20° F) , but the pumps are "No Fault Found" when returned for evaluation.Solution
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Ensure that the engine is stopped before any servicing or repair is performed. The Diesel Exhaust Fluid (DEF) system must have completed a proper shutdown. Service on the DEF pump prior to completion of a proper shutdown can result in DEF spray and spillage.
Do not turn off the battery disconnect switch until the indicator lamp has turned off. If the switch is turned off when the indicator lamp is illuminated, the Diesel Exhaust Fluid (DEF) system may not shut down properly. If the DEF system does not shut down properly, DEF could freeze and damage the pump and lines.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Cat Dealer Service Tool Catalog" or refer to Special Publication, PECJ0003, "Cat Shop Supplies and Tools Catalog" for tools and supplies suitable to collect and contain fluids on Cat products.Dispose of all fluids according to local regulations and mandates.
Note: Clean water should be used to wash spilled DEF off machine components and surfaces.Note: Wear gloves when handling the DEF filter.When troubleshooting the DEF pump during cold weather, the Compensator Plug within the DEF pump is designed to prevent pump operation if the DEF within the pump is frozen. The Compensator Plug will temporarily be pushed to the OFF position by the frozen DEF. The pump should return to the ON position once the DEF thaws.
Illustration 1 g06278274
(1) Protective cover
Remove protective cover (1).
Illustration 2 g06278289
(2) DEF filter cap
Use a suitable tool to remove DEF filter cap (2).
Illustration 3 g06278325
(3) Compensator
With the filter installed in the DEF pump, carefully remove compensator (3).
Illustration 4 g06278356
(A) 38 mm (1.5 inch)
(B) 97 mm (3.8 inch)
Inspect the compensator.If frozen DEF within the pump is identified as the root cause of the issue, submit a SIMSi report, complete with TIB number M0094916, CPI number 411775 and submit through the CPI feedback tool within the SIMSi.