Information injection-pump assembly
ZEXEL
104741-1402
1047411402
ISUZU
8944528192
8944528192

Rating:
Cross reference number
ZEXEL
104741-1402
1047411402
ISUZU
8944528192
8944528192
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
46.65
45.3
48
Boost pressure
mmHg
350
340
360
Average injection quantity
mm3/st.
49.4
48.9
49.9
Difference in delivery
mm3/st.
4.5
Basic
*
Remarks
CBS
CBS
Injection timing adjustment_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
61.3
60.8
61.8
Difference in delivery
mm3/st.
3.5
Basic
*
Remarks
Full
Full
Injection timing adjustment_03
Pump speed
r/min
2300
2300
2300
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
16.6
13.1
20.1
Injection timing adjustment_04
Pump speed
r/min
1800
1800
1800
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
58.6
55.1
62.1
Injection timing adjustment_05
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
61.3
60.3
62.3
Remarks
Full
Full
Injection timing adjustment_06
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
46.65
45.3
48
Boost pressure
mmHg
350
340
360
Average injection quantity
mm3/st.
49.4
48.4
50.4
Remarks
CBS
CBS
Injection timing adjustment_07
Pump speed
r/min
900
900
900
Boost pressure
kPa
46.65
45.3
48
Boost pressure
mmHg
350
340
360
Average injection quantity
mm3/st.
49.5
46
53
Injection timing adjustment_08
Pump speed
r/min
750
750
750
Boost pressure
kPa
24
22.7
25.3
Boost pressure
mmHg
180
170
190
Average injection quantity
mm3/st.
39.4
35.9
42.9
Injection timing adjustment_09
Pump speed
r/min
600
600
600
Boost pressure
kPa
13.35
12
14.7
Boost pressure
mmHg
100
90
110
Average injection quantity
mm3/st.
36
32
40
Injection quantity adjustment
Pump speed
r/min
2300
2300
2300
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
16.6
13.6
19.6
Difference in delivery
mm3/st.
4.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2600
2600
2600
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
5
Governor adjustment
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
7
5
9
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
7
5
9
Governor adjustment_03
Pump speed
r/min
500
500
500
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
80
60
100
Basic
*
Speed control lever angle
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Overflow quantity
cm3/min
399
270
528
Stop lever angle
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure
kPa
490.5
471
510
Pressure
kgf/cm2
5
4.8
5.2
Basic
*
Stop lever angle_02
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure
kPa
490.5
471
510
Pressure
kgf/cm2
5
4.8
5.2
Stop lever angle_03
Pump speed
r/min
1800
1800
1800
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure
kPa
549.5
520
579
Pressure
kgf/cm2
5.6
5.3
5.9
0000001101
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke
mm
5
4.8
5.2
Basic
*
_02
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke
mm
5
4.7
5.3
_03
Pump speed
r/min
1800
1800
1800
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke
mm
6.2
5.8
6.6
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
0.9
0.8
1
BCS stroke
mm
4.8
4.7
4.9
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42
Information:
Operation Description:Power to the ECM can fail due to an open circuit in the wire, or a blown fuse. A fuse is blown out as a result of an overloaded circuit. For example, the +battery connection is shorted to ground.Test Step 1. CHECK THE ECM FOR POWER AND GROUND.At the ECM, measure the voltage from contact 1 to contact 2. Expected Result:The voltage is system voltage.Results:
OK - The voltage is system voltage. The power supply circuit to the ECM is correct. STOP
NOT OK - The voltage is not system voltage. Proceed to Test Step 2.Test Step 2. CHECK THE FUSEWhenever the machine's electronic components fail to function, check the appropriate fuse for the ECM.
Check the fuse for the ECM.Expected Result:The fuse is correct.Results:
YES - The fuse is correct. Proceed to Test Step 3.
NO - The fuse is not correct.Repair: Replace the blown fuse or reset the circuit breaker. Observe the machine for a recurrence of the problem. If the problem persists, the reason for the blown fuse must be isolated and corrected.STOPTest Step 3. CHECK THE POWER WIRE TO THE ECM.
Turn the key start switch and the disconnect switch to the OFF position.
At the fuse, connect the lead from the multimeter to wire 113-RD.
At the ECM, connect the other lead from the multimeter to connector contact 1 and measure the resistance.Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The wiring circuit is correct. Proceed to Test Step 4.
NOT OK - The resistance measurement is greater than 5000 ohms. The wiring has an open circuit.Repair: Repair the wiring harness or replace the wiring harness. STOPTest Step 4. CHECK THE ECM GROUND CONNECTIONS.
The keyswitch and the disconnect switch remain in the OFF position.
At the ECM, measure the resistance from connector contact 2 to frame ground.Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The ground circuit is correct. The ECM may have failed. This is unlikely. Perform this entire procedure again. If the problem remains, the ECM may need to be replaced. Contact your dealerships for possible consultation with Caterpillar. This consultation may greatly reduce repair time.STOP
NOT OK - The resistance is greater than 5000 ohms. The ground circuit has failed.Repair: The ground circuit has failed. Repair the wiring harness or replace the wiring harness.STOP
OK - The voltage is system voltage. The power supply circuit to the ECM is correct. STOP
NOT OK - The voltage is not system voltage. Proceed to Test Step 2.Test Step 2. CHECK THE FUSEWhenever the machine's electronic components fail to function, check the appropriate fuse for the ECM.
Check the fuse for the ECM.Expected Result:The fuse is correct.Results:
YES - The fuse is correct. Proceed to Test Step 3.
NO - The fuse is not correct.Repair: Replace the blown fuse or reset the circuit breaker. Observe the machine for a recurrence of the problem. If the problem persists, the reason for the blown fuse must be isolated and corrected.STOPTest Step 3. CHECK THE POWER WIRE TO THE ECM.
Turn the key start switch and the disconnect switch to the OFF position.
At the fuse, connect the lead from the multimeter to wire 113-RD.
At the ECM, connect the other lead from the multimeter to connector contact 1 and measure the resistance.Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The wiring circuit is correct. Proceed to Test Step 4.
NOT OK - The resistance measurement is greater than 5000 ohms. The wiring has an open circuit.Repair: Repair the wiring harness or replace the wiring harness. STOPTest Step 4. CHECK THE ECM GROUND CONNECTIONS.
The keyswitch and the disconnect switch remain in the OFF position.
At the ECM, measure the resistance from connector contact 2 to frame ground.Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The ground circuit is correct. The ECM may have failed. This is unlikely. Perform this entire procedure again. If the problem remains, the ECM may need to be replaced. Contact your dealerships for possible consultation with Caterpillar. This consultation may greatly reduce repair time.STOP
NOT OK - The resistance is greater than 5000 ohms. The ground circuit has failed.Repair: The ground circuit has failed. Repair the wiring harness or replace the wiring harness.STOP