Information injection-pump assembly
ZEXEL
104741-1400
1047411400
ISUZU
8944528190
8944528190

Rating:
Cross reference number
ZEXEL
104741-1400
1047411400
ISUZU
8944528190
8944528190
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
900
900
900
Boost pressure
kPa
45.3
44
46.6
Boost pressure
mmHg
340
330
350
Average injection quantity
mm3/st.
49.5
49
50
Difference in delivery
mm3/st.
4.5
Basic
*
Oil temperature
degC
50
48
52
Remarks
CBS
CBS
Injection timing adjustment_02
Pump speed
r/min
1150
1150
1150
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
62.2
61.7
62.7
Difference in delivery
mm3/st.
3.5
Basic
*
Oil temperature
degC
50
48
52
Remarks
Full
Full
Injection timing adjustment_03
Pump speed
r/min
500
500
500
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
42.9
39.4
46.4
Oil temperature
degC
48
46
50
Injection timing adjustment_04
Pump speed
r/min
750
750
750
Boost pressure
kPa
8
6.7
9.3
Boost pressure
mmHg
60
50
70
Average injection quantity
mm3/st.
42.3
42.3
42.3
Oil temperature
degC
50
48
52
Injection timing adjustment_05
Pump speed
r/min
900
900
900
Boost pressure
kPa
45.3
44
46.6
Boost pressure
mmHg
340
330
350
Average injection quantity
mm3/st.
49.5
48.5
50.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_06
Pump speed
r/min
1150
1150
1150
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
62.2
61.2
63.2
Difference in delivery
mm3/st.
3.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_07
Pump speed
r/min
1900
1900
1900
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
53.2
49.2
57.2
Difference in delivery
mm3/st.
5.5
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
2300
2300
2300
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
27.5
24.5
30.5
Difference in delivery
mm3/st.
4.5
Basic
*
Oil temperature
degC
52
50
54
Injection quantity adjustment_02
Pump speed
r/min
2400
2400
2400
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
13
Oil temperature
degC
52
50
54
Injection quantity adjustment_03
Pump speed
r/min
2300
2300
2300
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
27.5
24.5
30.5
Difference in delivery
mm3/st.
4.5
Oil temperature
degC
52
50
54
Governor adjustment
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
9
7
11
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
9
7
11
Difference in delivery
mm3/st.
2
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
75
75
115
Basic
*
Oil temperature
degC
48
46
50
Remarks
Full
Full
Timer adjustment_02
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
95
75
115
Oil temperature
degC
48
46
50
Speed control lever angle
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Overflow quantity
cm3/min
400
270
530
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Pressure
kPa
490
470
510
Pressure
kgf/cm2
5
4.8
5.2
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Pressure
kPa
490
470
510
Pressure
kgf/cm2
5
4.8
5.2
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_03
Pump speed
r/min
2000
2000
2000
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Pressure
kPa
608
579
637
Pressure
kgf/cm2
6.2
5.9
6.5
Oil temperature
degC
50
48
52
0000001101
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Timer stroke
mm
4.8
4.6
5
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
1020
970
1070
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Timer stroke
mm
0.5
0.5
0.5
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1600
1600
1600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Timer stroke
mm
4.8
4.6
5
Basic
*
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
2000
2000
2000
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Timer stroke
mm
7.8
7.5
8.2
Oil temperature
degC
50
48
52
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
1
0.9
1.1
BCS stroke
mm
3.2
3
3.4
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42
Information:
Illustration 1 g01339995
Over Temperature Alarm
The Over Temperature alarm monitors the particulate filter temperature and the over temperature alarm produces an alarm if the temperature exceeds a configurable threshold. The operator is informed of an Over Temperature Alarm. The Over-Temperature Warning alarm is set to the "ON" state when the monitored temperature reaches or exceeds the Assert Alarm temperature value as configured by the user through the monitoring system. Pin 59 in the "ON" state will illuminate the optional Over-Temperature LED. Refer Systems Operation Troubleshooting, Testing and Adjusting, KENR6695-00, "Input Components".Through the CAT ET service tool, the users may configure the conditions to reset the Over-Temperature Warning alarm to "OFF" by choosing one of two methods:
The Over-Temperature Warning alarm will automatically be set to the "OFF" state when the monitored temperature drops below the Assert Alarm temperature value.
The Over-Temperature Warning alarm will stay latched in the "ON" state until cleared by the user through Cat ET.Over-Pressure Alarm
The Over-Pressure Alarm monitors the particulate filter pressure and annunciates an alarm if the pressure exeeds a configurable threshold. The operator should be informed of an Over-Pressure Alarm. There are two configurable Over-Pressure Alarm sets of conditions. By programming the two configurable Over-Pressure Alarm sets differently, one may be considered a Warning alarm and the other as a Critical alarm. The Warning alarm will be associated with Pin 60 (the optional Over-Pressure LED) and the Critical alarm will be associated with Pin 61 (the optional System Problem LED).
The Warning alarm is associated with the Over-Pressure LED.
The Critical alarm is associated with the System Problem LED.Refer Systems Operation Troubleshooting, Testing and Adjusting, KENR6695-00, "Input Components"Conditions To Set The Over-Pressure Alarm To The "ON" State
When the pressure exceeds the Pressure Threshold for the programmed percent of time (Duty Cycle) over the Time Interval, then the appropriate alarm (Over-Pressure or System Problem) is set to "ON". The pressure is sampled in 1 second intervals.Conditions To Set The Over-Pressure Alarm To The "OFF" State
The user may configure the conditions to reset the Over-Pressure alarms to "OFF" by choosing one of two methods:
The Over-Pressure alarm is set to the "OFF" state when the "ON" conditions are no longer met.
The Over-Pressure alarm will stay latched in the "ON" state until the Logged Event is cleared by the user through Cat ET.Configurable Parameters - The following parameters are configurable through the CAT ET service tool,
Particulate Trap Over-Pressure Warning Activation Time Percentage – Default is 10%
Particulate Trap Over-Pressure Warning Alarm Reset Configuration – Default is Manual
Particulate Trap Over-Pressure Critical Alarm Activation Time Percentage – Default is 10%Programmable Monitoring System
The purpose of the programmable monitoring system is to give the customers the ability to customize how the system reacts to possible engine damaging conditions. This feature reduces the number of custom personality modules, and part numbers, needed to meet widely varying customer needs. CAT ET can be used to view Programmable Monitoring System settings and customize the Programmable Monitoring System if allowed via security settings. Table 1 describes the programmable monitoring system. In