Information injection-pump assembly
ZEXEL
104740-3771
1047403771

Rating:
Components :
0. | INJECTION-PUMP ASSEMBLY | 104740-3771 |
1. | _ | |
2. | FUEL INJECTION PUMP | |
3. | NUMBER PLATE | |
4. | _ | |
5. | CAPSULE | |
6. | ADJUSTING DEVICE | |
7. | NOZZLE AND HOLDER ASSY | 105148-1112 |
8. | Nozzle and Holder | |
9. | Open Pre:MPa(Kqf/cm2) | 11.8(120) |
10. | NOZZLE-HOLDER | 105078-0012 |
11. | NOZZLE | 105007-1120 |
Include in #2:
104740-3771
as INJECTION-PUMP ASSEMBLY
Cross reference number
ZEXEL
104740-3771
1047403771
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
61.9
61.4
62.4
Difference in delivery
mm3/st.
4.5
Basic
*
Remarks
Full
Full
Injection timing adjustment_02
Pump speed
r/min
750
750
750
Boost pressure
kPa
44
42.7
45.3
Boost pressure
mmHg
330
320
340
Average injection quantity
mm3/st.
59.9
59.4
60.4
Basic
*
Remarks
CBS
CBS
Injection timing adjustment_03
Pump speed
r/min
2650
2650
2650
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
25.2
20.2
30.2
Injection timing adjustment_04
Pump speed
r/min
2100
2100
2100
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
55.3
52.8
57.8
Injection timing adjustment_05
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
61.9
60.9
62.9
Injection timing adjustment_06
Pump speed
r/min
750
750
750
Boost pressure
kPa
44
42.7
45.3
Boost pressure
mmHg
330
320
340
Average injection quantity
mm3/st.
59.9
58.9
60.9
Injection timing adjustment_07
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
45.3
42.8
47.8
Injection quantity adjustment
Pump speed
r/min
2650
2650
2650
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
25.2
22.2
28.2
Difference in delivery
mm3/st.
5.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
3050
3050
3050
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
5
Governor adjustment
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
8
6.5
9.5
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Governor adjustment_03
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
8
6
10
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
73
63
83
Basic
*
Speed control lever angle
Pump speed
r/min
375
375
375
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Overflow quantity
cm3/min
420
288
552
Stop lever angle
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Pressure
kPa
470.5
441
500
Pressure
kgf/cm2
4.8
4.5
5.1
Basic
*
Stop lever angle_02
Pump speed
r/min
600
600
600
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Pressure
kPa
313.5
284
343
Pressure
kgf/cm2
3.2
2.9
3.5
Stop lever angle_03
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Pressure
kPa
470.5
441
500
Pressure
kgf/cm2
4.8
4.5
5.1
Stop lever angle_04
Pump speed
r/min
2100
2100
2100
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Pressure
kPa
666.5
637
696
Pressure
kgf/cm2
6.8
6.5
7.1
0000001101
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Timer stroke
mm
3.7
3.5
3.9
Basic
*
_02
Pump speed
r/min
500
500
500
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Timer stroke
mm
1.2
0.6
1.8
_03
Pump speed
r/min
750
750
750
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Timer stroke
mm
2
1.4
2.6
_04
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Timer stroke
mm
3.7
3.3
4.1
_05
Pump speed
r/min
2100
2100
2100
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Timer stroke
mm
7.2
6.6
7.8
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
50.3
49.8
50.8
Timer stroke variation dT
mm
0.6
0.4
0.8
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
50.3
49.3
51.3
Timer stroke TA
mm
3.1
3.1
3.1
Timer stroke variation dT
mm
0.6
0.2
1
_03
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
73.35
72
74.7
Boost pressure
mmHg
550
540
560
Average injection quantity
mm3/st.
40.2
38.7
41.7
Timer stroke TA
mm
2.3
2.3
2.3
Timer stroke variation dT
mm
1.4
0.8
2
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1
0.9
1.1
BCS stroke
mm
4.7
4.6
4.8
Control lever angle alpha
deg.
59
55
63
Control lever angle beta
deg.
41
36
46
Test data Ex:
0000001801 POTENTIOMETER ADJUSTMENT

Adjustment of the potentiometer
Vi:Applied voltage
C:Position of the control lever
N:Pump speed (r/min)
V:Output voltage (V)
Q:Injection quantity (mm3/st)
A:Adjusting point
B:Checking point
C1:Idling
C2:Full speed
P1:Boost pressure
P2:Boost pressure
----------
----------
N1=750r/min V1=5+-0.03V V2=Above1V V3=(8.6)V Q1=35.5+-1cm3/1,000st Vi=10V P1=0kPa P2=0mmHg
----------
----------
N1=750r/min V1=5+-0.03V V2=Above1V V3=(8.6)V Q1=35.5+-1cm3/1,000st Vi=10V P1=0kPa P2=0mmHg
Information:
The vehicle must be parked on a level surface to perform this maintenance procedure.
1. Check the oil leve with the engine stopped. 2. Maintain the oil leve between the ADD and FULL marks in the FULL RANGE zone on the ENGINE STOPPED side of the dipstick. Do not fill the crankcase above the FULL RANGE zone. Operating your engine when the oil level is above the FULL RANGE zone could cause your crankshaft to dip into the oil. If this happens, the air bubbles created from the crankshaft dipping into the oil will reduce the lubricating characteristics of your oil and would result in the loss of power.If the dipstick does not have a FULL mark in the FULL RANGE zone, refer to calibrating the oil level gauge in the Dipsticks section of this manual or consult your Caterpillar dealer before operating the engine. 3. Add oil if necessary. See Refill Capacities and Lubricant Specifications for the size of your engine crankcase and proper oil to use. Remote mounted or auxiliary filters require additional oil. For all information pertaining to auxiliary filters, refer to the OEM or manufacturer's instructions.Leaks and Loose Connections
Inspect the Engine
For maximum service life of your truck engine, make a thorough under the hood inspection before starting the engine. Look for such items as oil or coolant leaks, loose bolts, worn fan belts, loose connections and trash build-up. Remove trash build-up and have repairs made as needed.Keep a close watch for leaks. If leaking is observed, find the source and correct the leak. If leaking is suspected, check the fluid levels more frequently than the recommended intervals prescribed in this publication. Continue monitoring fluid levels until a leak is found and fixed, or until the suspicion for a leak has been proven to be unwarranted.* Wipe all fittings, caps and plugs before servicing. * Inspect the radiator for leaks and trash build-up. * Inspect the radiator hoses for cracks and loose clamps. * Inspect the fan and accessory drive belts for cracks, breaks or other damage.Belts for multiple groove pulleys must be replaced as matched sets. If only one belt of a 2 or 3 belt set is replaced, it will carry more of a load than the belts not replaced since the older belts are stretched. The additional load on the new belt could cause it to break. * Inspect the water pump for leaks. Check weep hole for water pump breather filter, 4N1400 (1), blockage and replace if necessary. * Inspect the engine for oil leaks, such as front and rear crankshaft seals, oil pan, oil filters and valve covers. * Inspect the fuel system for leaks, loose fuel line clamps and fittings and loose or worn hoses. * Inspect wiring for loose connections and worn or frayed wires. * Inspect air intake system hoses and elbows for cracks and loose clamps. * Inspect engine-to-frame ground strap for good connection and condition.* All guards must be in place. Repair or replace missing or