104740-3670 ZEXEL 9 460 610 234 BOSCH INJECTION-PUMP ASSEMBLY 9460610234 1047403670


 

Information injection-pump assembly

BOSCH 9 460 610 234 9460610234
ZEXEL 104740-3670 1047403670
104740-3670 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 104740-3670 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

BOSCH 9 460 610 234 9460610234
ZEXEL 104740-3670 1047403670


Zexel num
Bosch num
Firm num
Name
104740-3670 
104740-3676 
9 460 610 234 
  MITSUBISHI
INJECTION-PUMP ASSEMBLY
4D56 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   45.8 45.3 46.3
Difference in delivery mm3/st.   3
Basic   *
Injection timing adjustment_02
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   18.1 13.1 23.1
Injection timing adjustment_03
Pump speed r/min   2100 2100 2100
Average injection quantity mm3/st.   39.2 37.2 41.2
Injection timing adjustment_04
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   45.8 44.8 46.8
Injection timing adjustment_05
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   44.3 42.3 46.3
Injection quantity adjustment
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   18.1 15.1 21.1
Difference in delivery mm3/st.   4
Injection quantity adjustment_02
Pump speed r/min   2900 2900 2900
Average injection quantity mm3/st.   5
Governor adjustment
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   8 6.5 9.5
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   3
Governor adjustment_03
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   8 6 10
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   7.3 6.3 8.3
Basic   *
Speed control lever angle
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1250 1250 1250
Overflow quantity cm3/min   420 288 552
Stop lever angle
Pump speed r/min   1250 1250 1250
Pressure kPa   470.5 441 500
Pressure kgf/cm2   4.8 4.5 5.1
Basic   *
Stop lever angle_02
Pump speed r/min   600 600 600
Pressure kPa   313.5 284 343
Pressure kgf/cm2   3.2 2.9 3.5
Stop lever angle_03
Pump speed r/min   1250 1250 1250
Pressure kPa   470.5 441 500
Pressure kgf/cm2   4.8 4.5 5.1
Stop lever angle_04
Pump speed r/min   2100 2100 2100
Pressure kPa   666.5 637 696
Pressure kgf/cm2   6.8 6.5 7.1
0000001101
Pump speed r/min   1250 1250 1250
Timer stroke mm   3.7 3.5 3.9
Basic   *
_02
Pump speed r/min   500 500 500
Timer stroke mm   1.2 0.6 1.8
_03
Pump speed r/min   750 750 750
Timer stroke mm   2 1.4 2.6
_04
Pump speed r/min   1250 1250 1250
Timer stroke mm   3.7 3.3 4.1
_05
Pump speed r/min   2100 2100 2100
Timer stroke mm   7.2 6.6 7.8
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   35.7 35.2 36.2
Timer stroke variation dT mm   0.6 0.4 0.8
Basic   *
_02
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   35.7 34.7 36.7
Timer stroke TA mm   3.1 3.1 3.1
Timer stroke variation dT mm   0.6 0.2 1
_03
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   28.2 26.7 29.7
Timer stroke TA mm   2.3 2.3 2.3
Timer stroke variation dT mm   1.4 0.8 2
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.2 1.1 1.3
Control lever angle alpha deg.   59 55 63
Control lever angle beta deg.   41 36 46

Test data Ex:

0000001801 M-FICD ADJUSTMENT

M-FICD adjustment Adjust so that the gap between the M-FICD lever and the idle lever position is L.
----------
L=1+-1mm
----------




Information:

Cooling System
Clean/Flush Coolant
Do not perform this maintenance until you read and understand the material in the Safety and Cooling System Specifications sections of this publication. This procedure is to be used for normal maintenance of cooling system surfaces to return to "like new" condition. For heavy build-up of scale and deposits, a severe acid-type, commercial cleaner or mechanical cleaning will be required.
1. Stop the engine and allow to cool. Loosen the radiator filler cap slowly and remove the cap to relieve pressure. 2. Remove the cooling system drain plug(s). Remove the drain plug (1) on bottom of water pump housing and/or radiator.Check water pump breather filter 4N1400 (2) for blockage or debris and replace if necessary.
Right Side View3. Open the cab heater valve to flush coolant from the cab heater. Remove the two block drain plugs from both sides of the engine. Allow coolant to drain.With the recent shortage and higher cost of new antifreeze and the disposal problems of used engine coolant, the interest in recycling the used engine coolant has sharply increased. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems.Filtering methods for reclaiming the used engine cooland do not reduce the level of chemicals in the water. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. The ethylene glycol and water obtained from this process can be treated with new chemical corrosion inhibitors to provide a like-new coolant.Commercial units are available to do this distillation process. Contact Caterpillar Service Technology Group: Outside Illinois: 1-800-542-TOOL Inside Illinois: 1-800-541-TOOL Canada: 1-800-523-TOOLRefer to Service Magazine article dated November 13, 1989 and/or Engine News article dated November 1989 for information regarding disposal and recycling of used coolant.4. Clean and install all drain plugs or close the drain valve. Refill the cooling system with clean water mixed with a 6 to 10 percent concentration of Caterpillar Cooling System Cleaner. Install radiator filler cap.Caterpillar Cooling System Cleaner is available through your Caterpillar dealer. A 9-12 gallon (33-47 L) cooling system capacity requires one gallon (3.8 L) of Caterpillar Cooling System Cleaner to accommodate the 6-10 percent concentration.5. Start and run the engine to circulate fluid in the cooling system for 1 1/2 hours.6. Stop the engine, remove radiator filler cap and cooling system drain plugs.7. Drain the cleaning solution. Flush the cooling system with clean water until draining water is clear. Clean and install all drain plugs and/or close the drain valve.8. Mix a solution of acceptable water and Caterpillar Antifreeze (which contains supplemental coolant additive). If NOT using Caterpillar Antifreeze, add 1 U.S. quart (1 L) of Caterpillar Supplemental Coolant Additive for every 8 U.S. gal (30 L) of cooling system capacity OR replace maintenance element with a precharge element only. Supplemental Coolant Additive or a coolant additive element (if equipped) should only be used when NOT refilling cooling system with Caterpillar Antifreeze. Refer to the topic Cooling System Specifications in this publication for all information regarding

Have questions with 104740-3670?





Group cross 104740-3670 ZEXEL

Mitsubishi 

104740-3670  

104740-3676 
9 460 610 234 
 
INJECTION-PUMP ASSEMBLY
4D56
9 460 610 275 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 610 300 
 
INJECTION-PUMP ASSEMBLY
4D56
9 460 610 396 
 
INJECTION-PUMP ASSEMBLY
9 460 610 587 
 
INJECTION-PUMP ASSEMBLY
9 460 610 770 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 613 386 
MD106444 
INJECTION-PUMP ASSEMBLY
4D56