Information injection-pump assembly
BOSCH
9 460 610 023
9460610023
ZEXEL
104740-2000
1047402000

Rating:
Cross reference number
BOSCH
9 460 610 023
9460610023
ZEXEL
104740-2000
1047402000
Zexel num
Bosch num
Firm num
Name
104740-2000
9 460 610 023
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
(Note)
For Japan: year/month/day (change sequence) 1986/5/15 (3)
For Japan: year/month/day (change sequence) 1986/5/15 (3)
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
31
30.5
31.5
Difference in delivery
mm3/st.
2.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
38.3
37.8
38.8
Basic
*
Injection timing adjustment_03
Pump speed
r/min
2700
2700
2700
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
10
7
13
Injection timing adjustment_04
Pump speed
r/min
2200
2200
2200
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
39.5
37
42
Injection timing adjustment_05
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
38.3
37.8
38.8
Injection timing adjustment_06
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
31
30.5
31.5
Injection timing adjustment_07
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
30.2
29.7
30.7
Difference in delivery
mm3/st.
2.5
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_08
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
37.4
36.9
37.9
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_09
Pump speed
r/min
2700
2700
2700
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
9.7
6.2
13.2
Remarks
For Japan
For Japan
Injection timing adjustment_10
Pump speed
r/min
2200
2200
2200
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
38.5
36
41
Remarks
For Japan
For Japan
Injection timing adjustment_11
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
37.4
36.4
38.4
Remarks
For Japan
For Japan
Injection timing adjustment_12
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
30.2
29.7
30.7
Remarks
For Japan
For Japan
Injection quantity adjustment
Pump speed
r/min
2700
2700
2700
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
10
7
13
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2800
2800
2800
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
6
Injection quantity adjustment_03
Pump speed
r/min
2700
2700
2700
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
9.7
6.7
12.7
Basic
*
Remarks
For Japan
For Japan
Injection quantity adjustment_04
Pump speed
r/min
2800
2800
2800
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Average injection quantity
mm3/st.
6
Remarks
For Japan
For Japan
Governor adjustment
Pump speed
r/min
325
325
325
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
6.2
4.7
7.7
Difference in delivery
mm3/st.
3
Basic
*
Governor adjustment_02
Pump speed
r/min
325
325
325
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
6.2
4.7
7.7
Governor adjustment_03
Pump speed
r/min
500
500
500
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Governor adjustment_04
Pump speed
r/min
325
325
325
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
6
4.5
7.5
Difference in delivery
mm3/st.
3
Basic
*
Remarks
For Japan
For Japan
Governor adjustment_05
Pump speed
r/min
325
325
325
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
6
4
8
Remarks
For Japan
For Japan
Governor adjustment_06
Pump speed
r/min
500
500
500
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Remarks
For Japan
For Japan
Boost compensator adjustment
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
12.3
7.3
17.3
Boost compensator adjustment_02
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
12
7
17
Remarks
For Japan
For Japan
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
41
41
Basic
*
Timer adjustment_02
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
40
40
Basic
*
Remarks
For Japan
For Japan
Speed control lever angle
Pump speed
r/min
325
325
325
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
Speed control lever angle_02
Pump speed
r/min
325
325
325
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan: Magnet OFF
For Japan: Magnet OFF
0000000901
Pump speed
r/min
900
900
900
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Overflow quantity
cm3/min
318
186
450
_02
Pump speed
r/min
900
900
900
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Overflow quantity
cm3/min
348
216
480
Remarks
For Japan
For Japan
Stop lever angle
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Pressure
kPa
323.5
294
353
Pressure
kgf/cm2
3.3
3
3.6
Basic
*
Stop lever angle_02
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Pressure
kPa
323.5
294
353
Pressure
kgf/cm2
3.3
3
3.6
Stop lever angle_03
Pump speed
r/min
1400
1400
1400
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Pressure
kPa
431.5
402
461
Pressure
kgf/cm2
4.4
4.1
4.7
Stop lever angle_04
Pump speed
r/min
2200
2200
2200
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Pressure
kPa
627.5
598
657
Pressure
kgf/cm2
6.4
6.1
6.7
Stop lever angle_05
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Pressure
kPa
313.5
284
343
Pressure
kgf/cm2
3.2
2.9
3.5
Basic
*
Remarks
For Japan
For Japan
Stop lever angle_06
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Pressure
kPa
314
275
353
Pressure
kgf/cm2
3.2
2.8
3.6
Remarks
For Japan
For Japan
Stop lever angle_07
Pump speed
r/min
1400
1400
1400
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Pressure
kPa
421.5
382
461
Pressure
kgf/cm2
4.3
3.9
4.7
Remarks
For Japan
For Japan
Stop lever angle_08
Pump speed
r/min
2200
2200
2200
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Pressure
kPa
618
579
657
Pressure
kgf/cm2
6.3
5.9
6.7
Remarks
For Japan
For Japan
0000001101
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Timer stroke
mm
2.6
2.3
2.9
Basic
*
_02
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Timer stroke
mm
2.6
2.3
2.9
_03
Pump speed
r/min
1400
1400
1400
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Timer stroke
mm
4.7
4.1
5.3
_04
Pump speed
r/min
2200
2200
2200
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Timer stroke
mm
8.15
7.7
8.6
_05
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Timer stroke
mm
2.5
2.2
2.8
Basic
*
Remarks
For Japan
For Japan
_06
Pump speed
r/min
900
900
900
Boost pressure
kPa
22.65
21.3
24
Boost pressure
mmHg
170
160
180
Timer stroke
mm
2.5
2.1
2.9
Remarks
For Japan
For Japan
_07
Pump speed
r/min
1400
1400
1400
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Timer stroke
mm
4.6
4
5.2
Remarks
For Japan
For Japan
_08
Pump speed
r/min
2200
2200
2200
Boost pressure
kPa
68
66.7
69.3
Boost pressure
mmHg
510
500
520
Timer stroke
mm
8.15
7.7
8.6
Remarks
For Japan
For Japan
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.75
5.65
5.85
MS dimension
mm
0.7
0.6
0.8
BCS stroke
mm
3.8
3.7
3.9
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
41
36
46
Control lever angle gamma
deg.
11
10.5
11.5
Information:
START BY:a. remove timing gear coverb. remove flywheel housingc. remove pistons and connecting rod assembliesd. remove crankshaft rear seal and wear sleevee. remove crankshaft front seal and wear sleeve Check the bearing caps for a number as to their location. If a number can not be seen, put a number on the left side of cylinder block and bearing cap. 1. Remove bolts (1) that hold main bearing caps (2) to the block, and remove main bearing caps (2). 2. Install one of the bolts from the front pulley in each end of the crankshaft.3. Fasten a hoist to crankshaft (3), and remove crankshaft (3) from the block. The weight is 159 kg (350 lb.). If new main bearings are not to be installed, keep old bearings with identification as to their location in cylinder block. 4. Use tooling (A) to remove the crankshaft gear.5. Use tooling (B) if necessary to remove the dowel and the pin.Install Crankshaft
If the crankshaft journals and bores for the block and rods were measured at disassembly and found to be within specifications, no further checks are necessary. However, if the serviceman still wants to measure the bearing clearances, Plastigage is recommended. Lead wire, shim stock or use of a dial bore gauge can damage the bearing surface.The serviceman must be very careful to use Plastigage correctly. The following points must be remembered:...Make sure that the backs of the bearings and the bores are clean and dry....Make sure that the bearing locking tabs are properly seated in their slots....The crankshaft must be free of oil where the Plastigage touches it....If the main bearing clearances are checked with the engine upright or on its side, the crankshaft must be supported. Use a jack under an adjacent crankshaft counterweight, and hold the crankshaft against the crown of the bearing. If the crankshaft is not supported, the weight of the crankshaft will cause incorrect readings....Put a piece of Plastigage on the crown of the bearing half that is in the cap. Do not allow the Plastigage to extend over the edge of the bearing....Install the bearing cap using the correct torque-turn specifications. Do not use an impact wrench. Be careful not to dislodge the bearing when the cap is installed....Do not turn the crankshaft with the Plastigage installed....Carefully remove the cap, but do not remove the Plastigage. Measure the width of the Plastigage while it is in the bearing cap or on the crankshaft journal. Do this by using the correct scale on the package. Record the measurements....Remove the Plastigage before installing the cap.When using Plastigage, the readings can sometimes be unclear. For example, all parts of the Plastigage are not the same width. Measure the major widths to make sure that they are within the specification range. Also, experience has shown that when checking clearances tighter than 0.10 mm (.004") the readings may be low by 0.013 to 0.025 mm (.0005 to .0010"). Out-of-round journals can give faulty readings. Also, journal taper may be indicated
If the crankshaft journals and bores for the block and rods were measured at disassembly and found to be within specifications, no further checks are necessary. However, if the serviceman still wants to measure the bearing clearances, Plastigage is recommended. Lead wire, shim stock or use of a dial bore gauge can damage the bearing surface.The serviceman must be very careful to use Plastigage correctly. The following points must be remembered:...Make sure that the backs of the bearings and the bores are clean and dry....Make sure that the bearing locking tabs are properly seated in their slots....The crankshaft must be free of oil where the Plastigage touches it....If the main bearing clearances are checked with the engine upright or on its side, the crankshaft must be supported. Use a jack under an adjacent crankshaft counterweight, and hold the crankshaft against the crown of the bearing. If the crankshaft is not supported, the weight of the crankshaft will cause incorrect readings....Put a piece of Plastigage on the crown of the bearing half that is in the cap. Do not allow the Plastigage to extend over the edge of the bearing....Install the bearing cap using the correct torque-turn specifications. Do not use an impact wrench. Be careful not to dislodge the bearing when the cap is installed....Do not turn the crankshaft with the Plastigage installed....Carefully remove the cap, but do not remove the Plastigage. Measure the width of the Plastigage while it is in the bearing cap or on the crankshaft journal. Do this by using the correct scale on the package. Record the measurements....Remove the Plastigage before installing the cap.When using Plastigage, the readings can sometimes be unclear. For example, all parts of the Plastigage are not the same width. Measure the major widths to make sure that they are within the specification range. Also, experience has shown that when checking clearances tighter than 0.10 mm (.004") the readings may be low by 0.013 to 0.025 mm (.0005 to .0010"). Out-of-round journals can give faulty readings. Also, journal taper may be indicated
Have questions with 104740-2000?
Group cross 104740-2000 ZEXEL
104740-2000
9 460 610 023
INJECTION-PUMP ASSEMBLY