104303-2210 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1043032210 65156011541b


 

Information injection-pump assembly

ZEXEL 104303-2210 1043032210
ISEKI 65156011541B 65156011541b
104303-2210 INJECTION-PUMP ASSEMBLY
Rating:
30
Buy INJECTION-PUMP ASSEMBLY 104303-2210 zexel genuine, new aftermarket engine parts with delivery

Service parts 104303-2210 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 104300-3570
3. GOVERNOR
4. SUPPLY PUMP 105248-1011
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105141-1981
11. Nozzle and Holder 6515300-1100E
12. Open Pre:MPa(Kqf/cm2) 11.8{120}
13. NOZZLE-HOLDER 105071-1261
14. NOZZLE 105000-1010
15. NOZZLE SET

Include in #1:

104303-2210 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
104303-2210 
 
65156011541B  ISEKI
INJECTION-PUMP ASSEMBLY
E3AE1 * K




Information:


Always use a wrench to hold the hex fitting on top of the master nozzle, when assembling or disassembling lines. If a wrench is not used, the master nozzle and manifold it is installed into may be damaged.
Check fuel line for "Close-in" Do NOT use fuel lines with an ID (inside diameter) LESS than 1.191 mm (0.0469 in). The fuel line ID can be checked using a 1.2 mm (.047 in) drill.If the drill bit can NOT be inserted into the fuel line high pressure hole, either drill out the line using a 1.6 mm (.063 in) drill or replace the fuel line with a new line. Use the same length and internal diameter lines each time the reference pump is tested.
If the fuel lines are not completely and thoroughly cleaned out after the drilling procedure, metal particles or foreign debris in the line will damage the master nozzles and contaminate the calibration fluid in the test stand.
After the hole has been drilled to the correct size, clean the line with solvent and remove any metal particles. Blow compressed air through the lines, after cleaning, to remove any solvent.
When using pressure air, wear a protective face shield and protective clothing. The maximum air pressure at the nozzle must be less than 205 kPa (30 psi) for cleaning purposes.
9. Identify fuel lines and nozzles in the same order as the reference pump plunger and barrels (1-6 or 1-12) and use the same lines and nozzles each time the reference pump is run on the test bench.10. Select two test points (speeds and shot settings) that will cover the delivery range realized in a dealer's shop.Always set up the test points using only the pump rack zero pin. Do not set the rack full load or idle stops.11. The test stand and reference pump should be run for ten minutes.Make sure test stand pressures and temperatures are within published specifications and that they are stable.12. Set the first test point.Take five samples (draws) and record the individual pump and barrel deliveries for each sample (draw).13. Examine pump and barrel sample data:* Are the samples consistent?The MAXIMUM allowable difference between the HIGH and LOW delivery pump and barrel in the reference pump should be three cc's.If there is NOT a three cc difference, swap pump and barrels in the pump housing (or check master nozzles for damage) and re-test UNTIL the maximum HIGH to LOW

Have questions with 104303-2210?





Group cross 104303-2210 ZEXEL

Iseki 

 
65156011551B 
INJECTION-PUMP ASSEMBLY
E3AE1
104303-2210  
 
65156011541B 
INJECTION-PUMP ASSEMBLY
E3AE1
 
65156011531B 
INJECTION-PUMP ASSEMBLY
E3AE1
 
65156010124B 
INJECTION-PUMP ASSEMBLY
E3AF1
 
65156012710C 
INJECTION-PUMP ASSEMBLY
E3AE1
 
65156011623D 
INJECTION-PUMP ASSEMBLY
E3AF1
 
65156011613D 
INJECTION-PUMP ASSEMBLY
E3AF1
 
65156011601A 
INJECTION-PUMP ASSEMBLY
E3AF1
9 400 616 431 
65156011990B 
INJECTION-PUMP ASSEMBLY
E3AF1
 
65156013380 
INJECTION-PUMP ASSEMBLY
E3AF1
Back to top