104303-1010 ZEXEL 9 400 616 426 BOSCH INJECTION-PUMP ASSEMBLY 9400616426 1043031010 2456310100


 

Information injection-pump assembly

BOSCH 9 400 616 426 9400616426
ZEXEL 104303-1010 1043031010
FUJI-HEAVY 2456310100 2456310100
104303-1010 INJECTION-PUMP ASSEMBLY
Rating:
16
Buy INJECTION-PUMP ASSEMBLY 104303-1010 zexel genuine, new aftermarket engine parts with delivery

Service parts 104303-1010 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 104300-6530
3. GOVERNOR
4. SUPPLY PUMP 105248-0320
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105141-2321
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 11.8{120}
13. NOZZLE-HOLDER 105071-1470
14. NOZZLE 105000-1740
15. NOZZLE SET

Include in #1:

104303-1010 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 616 426 9400616426
ZEXEL 104303-1010 1043031010
FUJI-HEAVY 2456310100 2456310100


Zexel num
Bosch num
Firm num
Name
104303-1010 
9 400 616 426 
2456310100  FUJI-HEAVY
INJECTION-PUMP ASSEMBLY
DW100 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-2
Pre-stroke mm   2.1 2.05 2.15
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 2
Cyl.1-2
deg.   240 239.5 240.5
Injection quantity adjustment
Adjusting point   A
Rack position   8.2
Pump speed r/min   1800 1800 1800
Average injection quantity mm3/st.   19.6 18.6 20.6
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   7.2+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   8 6.7 9.3
Max. variation between cylinders %   0 -13 13
Fixing the lever   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   C
Rack position   13+1
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   28 28
Fixing the lever   *

Test data Ex:

Governor adjustment

Test data 104303-1010
N:Pump speed R:Rack position (mm)
----------

----------

Speed control lever angle

Test data 104303-1010
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=20deg+-3deg b=34deg+-6deg

Stop lever angle

Test data 104303-1010
N:Pump normal S:Stop the pump.
----------

----------
a=19deg+-5deg b=(38deg)

Timing setting

Test data 104303-1010
(1)Pump vertical direction (2)Position of camshaft's key groove at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Information:

You must read and understand the warnings and instructions contained in the Safety section of this manual, before performing any operation or maintenance procedures.Cooling System
Do not perform this maintenance until you read and understand the material in the Safety and Cooling System Specifications sections of this publication.
Drain/Flush/Replace Coolant (Long Life Coolant/Antifreeze Only)
Caterpillar Long Life Coolant/Antifreeze should be replaced every 6,000 Service Hours or 4 Years, whichever comes first. Only clean water is needed to clean and flush the cooling system when LLCA is drained and replaced.Drain
1. Stop the engine and allow the engine to cool. Loosen the coolant filler cap slowly to relieve any pressure, and remove the cap.2. Remove the radiator drain plug, or open the radiator drain valve (if equipped). Remove the block and oil cooler drain plugs. Remove the drain plug from the bottom of the water pump housing. Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. Contact your Caterpillar for information regarding disposal and recycling of used coolant.
For information regarding disposal and recycling of used coolant:Contact Caterpillar Service Technology Group:Outside Illinois: 1-800-542-TOOLInside Illinois: 1-800-541-TOOLCanada: 1-800-523-TOOLFlush
4. Flush the cooling system with clean water to remove any debris.5. Clean and install all drain plugs and/or close the drain valve(s).6. Fill the cooling system with clean water. Install the filler cap. Operate the engine until warm 49 to 66°C (150 to 120°F).7. Stop the engine and allow the engine to cool. Loosen the coolant filler cap slowly to relieve any pressure, and remove the cap. Remove the cooling system drain plug(s) or open the drain valve. Allow the water to drain. Flush the cooling system with clean water.8. Repeat steps 6 and 7.Fill
9. Fill the cooling system with LLCA. Refer to the refill capacities chart in this manual for the amount of LLCA needed to refill your system.10. Start and run the engine with the filler cap removed. Allow the LLCA to warm, the thermostat to open, and the coolant level to stabilize. Add LLCA if necessary to bring the coolant to the proper level.11. Check the condition of the filler cap gasket. If the gasket is damaged, discard the old filler cap and install a new filler cap. If the gasket is not damaged, use a 9S8140 Service Tool (available from your Caterpillar dealer) to pressure test the filler cap. The correct filler cap pressure is stamped on the face of the filler cap. If the filler cap does not hold the correct pressure, install a new filler cap.12. Start the engine and inspect for coolant leaks and proper operating temperature.

Have questions with 104303-1010?





Group cross 104303-1010 ZEXEL

Fuji-Heavy 

9 400 616 425 
 
INJECTION-PUMP ASSEMBLY
DW100
104303-1010  
9 400 616 426 
2456310100 
INJECTION-PUMP ASSEMBLY
DW100
 
2456310200 
INJECTION-PUMP ASSEMBLY
DW100
9 400 616 427 
2456310210 
INJECTION-PUMP ASSEMBLY
DW100
9 400 616 428 
2456310300 
INJECTION-PUMP ASSEMBLY
DW100
Back to top