103682-0481 ZEXEL 9 400 611 757 BOSCH INJECTION-PUMP ASSEMBLY 9400611757 1036820481 75k47001b


 

Information injection-pump assembly

BOSCH 9 400 611 757 9400611757
ZEXEL 103682-0481 1036820481
NIIGATA-URAWA 75K47001B 75k47001b
103682-0481 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 103682-0481 zexel genuine, new aftermarket engine parts with delivery

Service parts 103682-0481 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 103068-1090
3. GOVERNOR 105455-1031
4. SUPPLY PUMP 105235-1900
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2)
13. NOZZLE-HOLDER
14. NOZZLE
15. NOZZLE SET

Include in #1:

103682-0481 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
103682-0481 
103682-0482 
9 400 611 757 
75K47001B  NIIGATA-URAWA
INJECTION-PUMP ASSEMBLY
6NSDL * K 14BS PE4-8Z PE
103682-0481 
103682-0482 
9 400 611 757 
75K47001B  NIIGATA-TEKKOU
INJECTION-PUMP ASSEMBLY
6NSDL * K 14BS PE4-8Z PE




Information:

Problem 4
The starting motor remains engaged or the starting motor continues to run after the engine is running.
Check the components of the starting circuit.
Measure the voltages at terminal (TS-26) of the junction box and at terminal (ESS-12) of the electronic speed switch while the engine is running. Result
The voltage at both terminals is zero volts.The problem is in the starting motor (SM), the pinion solenoid (PS), or the magnetic switch (MS). Repair the faulty component. STOP.
The voltage at terminal (ESS-12) is between 15 volts and 32 volts. The voltage at terminal (TS-26) is above 15 volts or below 15 volts but not zero volts.The contacts for the crank terminate (CT) switch of the electronic speed switch (ESS) do not open. Refer to Testing and Adjusting, "Crank Terminate Speed Calibration". If the ESS is not faulty, check diode (D3). Refer to Testing and Adjusting, "Diode Test".
The voltage at both terminals is between 15 volts and 32 volts.The voltage at the terminals is greater than zero volts. During the normal operation of the start/stop switch, the start/stop switch opens across the contacts of the START position. Also, the start/stop switch closes across the contacts of the RUN position. The switch closes when the toggle or the lever of the switch moves from the START position to the RUN position. Repair the switch if the voltage is zero.
The voltage at terminal (ESS-12) is not zero.The CT contacts of the ESS are not opening. Refer to Testing and Adjusting, "Crank Terminate Speed Calibration".Problem 5
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the overspeed setting on the electronic speed switch (ESS).
Observe the indicator lamp on the ESS.
Reset the air shutoff lever, if equipped. Result
The indicator lamp on the ESS is turned on.Overspeed is indicated as the cause of the engine shutdown. Press the "RESET" button of the ESS. Find the cause of the overspeed. Refer to Testing and Adjusting, "Overspeed Verification Test" and Testing and Adjusting, "Overspeed Calibration". If the overspeed is adjusted properly and the problem persists, check the shielded cable. Only the shield should be connected to terminal 2 on the ESS. STOP.
The indicator lamp is turned off.Go to Step 2.
Check the oil pressure switches.
Connect a jumper between terminals (TS-9) and (TS-14) of the junction box.
Start the engine. Result
The engine starts and the engine runs.The problem is in the oil pressure switches. Go to Step 7 of "Problem 3".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 3.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".Note: If the water temperature contactor switch causes overheating go to Step 8 of "Problem 1". If the water temperature contactor switch is not the problem, go to Step 1of "Problem 1".
Check the slave relay (SR1).
Disconnect the jumper from terminals (TS-9) and (TD-14).
Connect a jumper between terminals (TS-14) and

Have questions with 103682-0481?





Group cross 103682-0481 ZEXEL

Shinko-Engin. 

 
214090030 
INJECTION-PUMP ASSEMBLY
S12V18
 
211090380 
INJECTION-PUMP ASSEMBLY
S618

Komatsu 

9 400 616 362 
6162731652 
INJECTION-PUMP ASSEMBLY
SA6D160
 
6162731681 
INJECTION-PUMP ASSEMBLY
SA6D170
 
 
INJECTION-PUMP ASSEMBLY
SA6D160
 
 
INJECTION-PUMP ASSEMBLY
SA6D170
 
6162731653 
INJECTION-PUMP ASSEMBLY
SA6D160
9 400 616 363 
6162731654 
INJECTION-PUMP ASSEMBLY
SA6D160
 
6162731682 
INJECTION-PUMP ASSEMBLY
SA6D170
9 400 616 364 
6162731683 
INJECTION-PUMP ASSEMBLY
SA6D170

Niigata-Urawa 

 
75K47001A 
INJECTION-PUMP ASSEMBLY
6NSDL
103682-0481  

103682-0482 
9 400 611 757 
75K47001B 
INJECTION-PUMP ASSEMBLY
6NSDL

Niigata-Tekkou 

103682-0481  

103682-0482 
9 400 611 757 
75K47001B 
INJECTION-PUMP ASSEMBLY
6NSDL
9 400 616 365 
75K47001C 
INJECTION-PUMP ASSEMBLY
6NSDL

Komatsu 

9 400 616 366 
6162732710 
INJECTION-PUMP ASSEMBLY
6M160A
F 019 Z20 054 
6162732711 
INJECTION-PUMP ASSEMBLY
6M160A
Back to top