101701-9150 ZEXEL F 019 Z10 187 BOSCH INJECTION-PUMP ASSEMBLY f019z10187 1017019150 16714z6000


 

Information injection-pump assembly

BOSCH F 019 Z10 187 f019z10187
ZEXEL 101701-9150 1017019150
NISSAN-DIESEL 16714Z6000 16714z6000
101701-9150 INJECTION-PUMP ASSEMBLY
Rating:
15
Buy INJECTION-PUMP ASSEMBLY 101701-9150 zexel genuine, new aftermarket engine parts with delivery

Service parts 101701-9150 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-6620
3. GOVERNOR 105932-1940
4. SUPPLY PUMP 105220-7150
5. AUTOM. ADVANCE MECHANIS 105672-5260
6. COUPLING PLATE 105662-1470
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-7290
11. Nozzle and Holder 16600Z6004
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/22.6{230}
13. NOZZLE-HOLDER 105048-4020
14. NOZZLE
15. NOZZLE SET 105019-1110

Include in #1:

101701-9150 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101701-9150 
101701-9151 
F 019 Z10 187 
16714Z6000  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
MD92 * K




Information:


Table 1
CCM Error Codes    
CCM Error Code     Explanation     Action Required    
E00     No fault, normal operating mode     None    
E01     Setpoint (EEPROM) fault     CCM passwords, unit addresses, or communication setups are corrupted. Reprogram from Phone-Book and Utilities pull-down menus.    
E02     M5X message error     Check customer generated M5X code    
E03     Memory backup battery is weak     Change battery. Refer to Operation and Maintenance Manual, "Battery - Replace"    
E04     RS-232C link short circuit fault     Check RS-232C cable, PC port, and CCM port    
E05     Internal buffer overflow on RS-232C or Data Link fault     Possibly caused by a slower than acceptable communication rate from the RS-232C port or an open CAT Data Link connection during RS-232C transmission. Increase communication rate and check CAT Data Link wires.    
E06     Invalid CAT Data Link Message fault     Caused by:
1. Too much traffic on CAT Data Link.
2. CAT Data Link wires too long.
Remove ECAP or other Caterpillar electronic service tool devices overloading CAT Data Link and check CAT Data Link wires.    
E07     Miscellaneous CAT Data Link Fault     Caused by:
1. (+/-) CAT Data Link shorted to (+/-) battery.
2. Internal hardware fault in CCM.
Check CAT Data Link wiring and then replace CCM if wiring is good.    
E08     RS-232C link message fault (parity, data size)     Check RS-232C protocol (communication rate, data bits, stop bits, parity) of CCM and PC.    
888     Internal CCM fault     Replace the CCM.    

Have questions with 101701-9150?





Group cross 101701-9150 ZEXEL

Nissan-Diesel 

9 400 616 182 
16714Z5505 
INJECTION-PUMP ASSEMBLY
FE6EH
 
16714Z5506 
INJECTION-PUMP ASSEMBLY
FE6E
 
16714Z5560 
INJECTION-PUMP ASSEMBLY
FE6E
9 400 616 183 
16714Z5507 
INJECTION-PUMP ASSEMBLY
FE6E
9 400 616 184 
16714Z5508 
INJECTION-PUMP ASSEMBLY
FE6E
9 400 616 185 
16714Z5509 
INJECTION-PUMP ASSEMBLY
FE6E
101701-9150  

101701-9151 
F 019 Z10 187 
16714Z6000 
INJECTION-PUMP ASSEMBLY
MD92
F 01G 09U 06Z 
16714Z6018 
INJECTION-PUMP ASSEMBLY
MD92
F 019 Z10 188 
16714Z6001 
INJECTION-PUMP ASSEMBLY
MD92
F 01G 09U 070 
16714Z6019 
INJECTION-PUMP ASSEMBLY
MD92
F 019 Z10 259 
16714Z6002 
INJECTION-PUMP ASSEMBLY
MD92
F 01G 09U 071 
16714Z6060 
INJECTION-PUMP ASSEMBLY
MD92
9 400 616 186 
16714Z6003 
INJECTION-PUMP ASSEMBLY
MD92
9 400 616 187 
16714Z6004 
INJECTION-PUMP ASSEMBLY
MD92
Back to top