101701-9111 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1017019111 16714z5560


 

Information injection-pump assembly

ZEXEL 101701-9111 1017019111
NISSAN-DIESEL 16714Z5560 16714z5560
101701-9111 INJECTION-PUMP ASSEMBLY
Rating:
11
Buy INJECTION-PUMP ASSEMBLY 101701-9111 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
101701-9111 
 
16714Z5560  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
FE6E * K




Information:

password protection for the CCM is initially enabled. Password protection may be necessary for some applications. Use the following procedure to enable password protection. Changing the password protection can be done with the PC software for the CCM . The password protection can also be changed by using a host device to write the IIDs.Disabling PasswordsTo disable the passwords, the AA12 and AA8A PIDs must be used.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA8A with the level 3 password. This will set the security level in the CCM to level 3. The message will be 5000340C0061AA8Ab1b2b3b4b5b6b7b8cs. The example above shows that b1 through b8 are the ASCII characters of the password. If the password is all spaces, simply end the message after PID AA8A. Do not include any of the data bytes. The CCM will automatically add spaces when a character is not present.
Use IID 34 with a unit number of 61. Write PID AA 12 with bit 3 set. This will disable the password protection. The message will be 500034050061AA1204cs. This message will disable the passwords. Baud rate changes will be enabled. The CCM will be set for a direct connection. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way. Note: When the passwords are disabled, all three passwords are set to all blanks (spaces).Enabling PasswordsThe AA12 and the F012 PIDs must be used in order to enable the password protection.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA12 to clear bit 3. The message format will be 500034050061AA1200cs. This message will enable the following items: passwords, change of baud rate and set the CCM for direct connect. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way.
In order to enable the changes, the power to the CCM must be cycled or the security level must be written to zero. The security level is written to zero by using IID 34. The message will be 500034050061F01200cs. Note: When the passwords were disabled, each character was set to a blank or space. Set the level 3 password on the CCM to something other than spaces.

Have questions with 101701-9111?





Group cross 101701-9111 ZEXEL

Nissan-Diesel 

9 400 616 182 
16714Z5505 
INJECTION-PUMP ASSEMBLY
FE6EH
 
16714Z5506 
INJECTION-PUMP ASSEMBLY
FE6E
101701-9111  
 
16714Z5560 
INJECTION-PUMP ASSEMBLY
FE6E
9 400 616 183 
16714Z5507 
INJECTION-PUMP ASSEMBLY
FE6E
9 400 616 184 
16714Z5508 
INJECTION-PUMP ASSEMBLY
FE6E
9 400 616 185 
16714Z5509 
INJECTION-PUMP ASSEMBLY
FE6E
F 019 Z10 187 
16714Z6000 
INJECTION-PUMP ASSEMBLY
MD92
F 01G 09U 06Z 
16714Z6018 
INJECTION-PUMP ASSEMBLY
MD92
F 019 Z10 188 
16714Z6001 
INJECTION-PUMP ASSEMBLY
MD92
F 01G 09U 070 
16714Z6019 
INJECTION-PUMP ASSEMBLY
MD92
F 019 Z10 259 
16714Z6002 
INJECTION-PUMP ASSEMBLY
MD92
F 01G 09U 071 
16714Z6060 
INJECTION-PUMP ASSEMBLY
MD92
9 400 616 186 
16714Z6003 
INJECTION-PUMP ASSEMBLY
MD92
9 400 616 187 
16714Z6004 
INJECTION-PUMP ASSEMBLY
MD92
Back to top