101696-9600 ZEXEL 9 400 610 811 BOSCH INJECTION-PUMP ASSEMBLY 9400610811 1016969600 16713z6610


 

Information injection-pump assembly

BOSCH 9 400 610 811 9400610811
ZEXEL 101696-9600 1016969600
NISSAN-DIESEL 16713Z6610 16713z6610
101696-9600 INJECTION-PUMP ASSEMBLY
Rating:
12
Buy INJECTION-PUMP ASSEMBLY 101696-9600 zexel genuine, new aftermarket engine parts with delivery

Service parts 101696-9600 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101069-5040
3. GOVERNOR 105921-8270
4. SUPPLY PUMP 105220-7010
5. AUTOM. ADVANCE MECHANIS 105672-4040
6. COUPLING PLATE 105662-1380
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-7990
11. Nozzle and Holder 16600-Z5664
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/19.6{200}
13. NOZZLE-HOLDER 105030-4140
14. NOZZLE 105015-8680
15. NOZZLE SET

Include in #1:

101696-9600 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101696-9600 
9 400 610 811 
16713Z6610  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
FE6TA * K 14BF PE6AD PE




Information:


To avoid possible engine damage or another immediate shutdown, the water temperature fault must be corrected before attempting to restart the engine.
Even though the starter motor circuit can now be engaged, there is no fuel flow to the engine. The fuel flow to the engine is stopped until the coolant temperature falls below the rating for the water temperature contactor switch (WTS). When the coolant temperature falls below the rating for the water temperature contactor switch (WTS), the contactor switch opens again. The fuel shutoff solenoid is de-energized when the switch reopens. This allows fuel flow to the engine. The engine can then be restarted.When the coolant temperature decreases below the rating of the water temperature contactor switch, the switch opens again. The time delay relay also causes a delay of 70 seconds before the fuel shutoff solenoid (FSOS) is de-energized. The engine can then be restarted.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (-) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 34) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from terminal (TS-28) (line 27) and current flows from terminal (TS-31) (line 35), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 27) and (TS-31) (line 35) flows through the preregulator (PR) (line 38) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine.Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical

Have questions with 101696-9600?





Group cross 101696-9600 ZEXEL

Nissan-Diesel 

101696-9600  
9 400 610 811 
16713Z6610 
INJECTION-PUMP ASSEMBLY
FE6TA
9 400 610 812 
16713Z6611 
INJECTION-PUMP ASSEMBLY
FE6TB
 
16713Z6617 
INJECTION-PUMP ASSEMBLY
FE6T
 
16713Z6618 
INJECTION-PUMP ASSEMBLY
FE6T
9 400 610 813 
16713Z6672 
INJECTION-PUMP ASSEMBLY
FE6T
9 400 610 814 
16713Z6673 
INJECTION-PUMP ASSEMBLY
FE6TA
9 400 611 448 
 
INJECTION-PUMP ASSEMBLY
FE6TA

Nissan-Diesel 

9 400 616 154 
16713Z6977 
INJECTION-PUMP ASSEMBLY
FE6TA
9 400 610 815 
16713Z6674 
INJECTION-PUMP ASSEMBLY
FE6TB
F 01G 09U 06K 
16713Z6979 
INJECTION-PUMP ASSEMBLY
FE6TB
9 400 610 816 
16713Z6676 
INJECTION-PUMP ASSEMBLY
FE6T
 
16713Z6677 
INJECTION-PUMP ASSEMBLY
FE6T
 
16713Z6776 
INJECTION-PUMP ASSEMBLY
FE6T
 
16713Z6678 
INJECTION-PUMP ASSEMBLY
FE6T
 
16713Z6777 
INJECTION-PUMP ASSEMBLY
FE6T
Back to top