101695-3070 ZEXEL 9 400 616 090 BOSCH INJECTION-PUMP ASSEMBLY 9400616090 1016953070 6207711335


 

Information injection-pump assembly

BOSCH 9 400 616 090 9400616090
ZEXEL 101695-3070 1016953070
KOMATSU 6207711335 6207711335
101695-3070 INJECTION-PUMP ASSEMBLY
Rating:
24
Buy INJECTION-PUMP ASSEMBLY 101695-3070 zexel genuine, new aftermarket engine parts with delivery

Service parts 101695-3070 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101069-9420
3. GOVERNOR 105400-6660
4. SUPPLY PUMP 105220-5610
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5631
11. Nozzle and Holder 6207-11-3102
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105048-3300
14. NOZZLE 105017-1450
15. NOZZLE SET

Include in #1:

101695-3070 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 616 090 9400616090
ZEXEL 101695-3070 1016953070
KOMATSU 6207711335 6207711335


Zexel num
Bosch num
Firm num
Name
101695-3070 
9 400 616 090 
6207711335  KOMATSU
INJECTION-PUMP ASSEMBLY
S6D95L K 14BE INJECTION PUMP ASSY PE6A PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.9
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   45.3 44.3 46.3
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   10.6+-0. 5
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   12.5 11.5 13.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101695-3070
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT: RAL (3)Rack difference between N = N1 and N = N2
----------
K=12 RAL=15+0.2mm N1=1200r/min N2=800r/min
----------

Speed control lever angle

Test data 101695-3070
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=17deg+-5deg b=28deg+-5deg

Stop lever angle

Test data 101695-3070
N:Pump normal S:Stop the pump.
----------

----------
a=26.5deg+-5deg b=53deg+-5deg

Timing setting

Test data 101695-3070
(1)Pump vertical direction (2)Position of key groove at No 1 cylinder's beginning of injection (3)Stamp aligning marks on the pump housing flange. (4)-
----------

----------
a=59deg36min+-3deg b=0deg24min+-30min




Information:

Start By:a. remove timing gear coverb. remove flywheel housingc. remove pistons and connecting rod assembliesd. remove crankshaft rear seal and wear sleevee. remove crankshaft front seal and wear sleeve Check the bearing caps for a number as to their location. If a number can not be seen, put a number on the left side of cylinder block and bearing cap. 1. Remove bolts (1) that hold main bearing caps (2) to the block, and remove main bearing caps (2). 2. Install one of the bolts from the front pulley in each end of the crankshaft.3. Fasten a hoist to crankshaft (3), and remove crankshaft (3) from the block. The weight is 159 kg (350 lb.). If new main bearings are not to be installed, keep old bearings with identification as to their location in cylinder block. 4. Use tooling (A) to remove the crankshaft gear.5. Use tooling (B) if necessary to remove the dowel and the pin.Install Crankshaft
If the crankshaft journals and bores for the block and rods were measured at disassembly and found to be within specifications, no further checks are necessary. However, if the serviceman still wants to measure the bearing clearances, Plastigage is recommended. Lead wire, shim stock or use of a dial bore gauge can damage the bearing surface.The serviceman must be very careful to use Plastigage, tool (B) correctly. The following points must be remembered:... Make sure that the backs of the bearings and the bores are clean and dry.... Make sure that the bearing locking tabs are properly seated in their slots.... The crankshaft must be free of oil where the Plastigage touches it.... If the main bearing clearances are checked with the engine upright or on its side, the crankshaft must be supported. Use a jack under an adjacent crankshaft counterweight and hold the crankshaft against the crown of the bearing. If the crankshaft is not supported, the weight of the crankshaft will cause incorrect readings.... Put a piece of Plastigage on the crown of the bearing half that is in the cap. Do not allow the Plastigage to extend over the edge of the bearing.... Install the bearing cap using the correct torque-turn specifications. Do not use an impact wrench. Be careful not to dislodge the bearing when the cap is installed.... Do not turn the crankshaft with the Plastigage installed.... Carefully remove the cap but do not remove the Plastigage. Measure the width of the Plastigage while it is in the bearing cap or on the crankshaft journal. Do this by using the correct scale on the package. Record the measurements.... Remove the Plastigage before reinstalling the cap.When using Plastigage, the readings can sometimes be unclear. For example, all parts of the Plastigage are not the same width. Measure the major widths to make sure that they are within the specification range. Also, experience has shown that when checking clearances tighter than 0.10 mm (.004") the readings may be low by 0.013 to 0.025 mm (.0005 to .0010"). Out-of-round

Have questions with 101695-3070?





Group cross 101695-3070 ZEXEL

Komatsu 

9 400 616 087 
6207711391 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 088 
6207711243 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 611 333 
6207711271 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 611 611 
6207711221 
INJECTION-PUMP ASSEMBLY
S6D95L
 
6207711263 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 612 333 
6207711211 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 089 
6207721261 
INJECTION-PUMP ASSEMBLY
S6D95L
101695-3070  
9 400 616 090 
6207711335 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 091 
6207711941 
INJECTION-PUMP ASSEMBLY
S6D95L
F 019 Z10 613 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 612 622 
6207711381 
INJECTION-PUMP ASSEMBLY
S6D95L