101692-3910 ZEXEL 9 400 612 339 BOSCH INJECTION-PUMP ASSEMBLY 9400612339 1016923910 6209711262


 

Information injection-pump assembly

BOSCH 9 400 612 339 9400612339
ZEXEL 101692-3910 1016923910
KOMATSU 6209711262 6209711262
101692-3910 INJECTION-PUMP ASSEMBLY
Rating:
48
Buy INJECTION-PUMP ASSEMBLY 101692-3910 zexel genuine, new aftermarket engine parts with delivery

Service parts 101692-3910 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101069-9370
3. GOVERNOR 105400-5532
4. SUPPLY PUMP 105220-5280
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5631
11. Nozzle and Holder 6207-11-3102
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105048-3300
14. NOZZLE 105017-1450
15. NOZZLE SET

Include in #1:

101692-3910 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 339 9400612339
ZEXEL 101692-3910 1016923910
KOMATSU 6209711262 6209711262


Zexel num
Bosch num
Firm num
Name
101692-3910 
101692-3920 
9 400 612 339 
6209711262  KOMATSU
INJECTION-PUMP ASSEMBLY
SA6D95L K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-7420
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.2 3.15 3.25
Rack position
Point A
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.6
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   74.6 73.6 75.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   8.2+-0.5
Pump speed r/min   450 450 450
Average injection quantity mm3/st.   12.5 11.5 13.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101692-3910
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT: RAL (3)Rack difference from N = N1 (4)Rack difference between N = N2 and N = N3
----------
K=14 RAL=15+0.2mm N1=1100r/min N2=1100r/min N3=450r/min
----------

Speed control lever angle

Test data 101692-3910
F:Full speed I:Idle S:Stop (1)Use the hole at R = aa
----------
aa=80mm
----------
a=34deg+-5deg b=19deg+-3deg c=32deg+-3deg

Timing setting

Test data 101692-3910
(1)Pump vertical direction (2)Position of key groove at No 1 cylinder's beginning of injection (3)Stamp aligning marks on the pump housing flange. (4)- (5)-
----------

----------
a=58deg+-3deg b=2deg+-30min




Information:

ELC cooling systems can withstand contamination of up to ten percent of conventional HD coolant/antifreeze. If the contamination exceeds ten percent of the total system capacity, perform either one of the following two procedures:* Drain the cooling system. Flush the system with clean water. Refill the system with ELC.* Maintain the cooling system as if the system is filled with conventional HD coolant/antifreeze.Commercial Extended Life Coolant
If Caterpillar extended life coolant is not used, select a commercial extended life coolant that meets the Caterpillar EC-1 specification. Do not use a product that is labeled as an extended life coolant but does not meet the Caterpillar EC-1 specification. Follow the coolant maintenance guidelines of the commercial extended life coolant supplier. In all cases, use distilled or deionized water or use water that has the properties listed in the Caterpillar Water Quality Limits chart.Caterpillar Diesel Engine Antifreeze/Coolant (DEAC)
For cooling systems using conventional HD coolant, Caterpillar recommends the use of Caterpillar Diesel Engine Antifreeze/Coolant (DEAC). DEAC is an alkaline type, single-phase, ethylene glycol-based antifreeze/coolant. DEAC contains inorganic corrosion inhibitors and anti-foaming agents.Contact your Caterpillar dealer for part numbers and available container sizes.Caterpillar DEAC is available premixed with distilled water in a 50/50 concentration. If DEAC concentrate is used, Caterpillar recommends mixing the concentrate with distilled or deionized water. If distilled or deionized water is not available, use water that has the properties listed in the Caterpillar Water Quality Limits chart.Caterpillar Supplemental Coolant Additive (SCA)
Caterpillar Supplemental Coolant Additive (SCA) is effective in preventing corrosion on all metals. Caterpillar SCA also prevents the formation of mineral deposits, prevents liner cavitation, and eliminates coolant foaming.Caterpillar DEAC is formulated with the correct level of Caterpillar SCA. Additional SCA is NOT needed when the cooling system is initially filled with DEAC.Contact your Caterpillar dealer for part numbers and available container sizes.Commercial Heavy Duty (HD) Coolant/Antifreeze and SCA
If Caterpillar DEAC is not used, select a low silicate commercial HD coolant/antifreeze that meets ASTM D5345 or D4985 specifications.When a commercial HD coolant/antifreeze is used, the cooling system should be treated with three to six percent Caterpillar SCA by volume. Refer to the Caterpillar SCA Requirements for Heavy Duty Coolant/Antifreeze chart. If Caterpillar SCA is not used, select a commercial SCA. The commercial SCA must provide a minimum of 1200 mg/L or 1200 ppm (70 grains/US gal) nitrites in the final coolant mixture. Follow the coolant maintenance guidelines of the commercial SCA supplier.HD coolant/antifreezes that meet ASTM D5345 or D4985 specifications DO require SCA treatment at initial fill, and on a maintenance basis.When mixing concentrated coolants, use distilled or deionized water or use water that has the properties listed in the Caterpillar Water Quality Limits chart.Heavy Duty Coolant/Antifreeze Cooling System Maintenance
Never operate an engine without thermostats in the cooling system. Thermostats maintain the engine coolant at the proper operating temperature. Cooling system problems can develop without thermostats.
Check the coolant/antifreeze solution (glycol content) frequently to ensure adequate anti-boil and anti-freeze protection. Caterpillar recommends the use of a refractometer for checking the

Have questions with 101692-3910?





Group cross 101692-3910 ZEXEL

Komatsu 

 
 
INJECTION-PUMP ASSEMBLY
S6D95L
101692-3910  

101692-3920 
9 400 612 339 
6209711262 
INJECTION-PUMP ASSEMBLY
SA6D95L
9 400 616 057 
6209711210 
INJECTION-PUMP ASSEMBLY
SA6D95L
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 511 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 610 312 
6206711480 
INJECTION-PUMP ASSEMBLY
6D95L
 
6207711611 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 058 
6207711612 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 059 
6209711311 
INJECTION-PUMP ASSEMBLY
SA6D95L
F 019 Z10 512 
6207711321 
INJECTION-PUMP ASSEMBLY
S6D95L
 
6207711371 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 060 
6207711281 
INJECTION-PUMP ASSEMBLY
S6D95L
9 400 616 061 
6207711361 
INJECTION-PUMP ASSEMBLY
S6D95L
Back to top