101692-2491 ZEXEL 9 400 616 017 BOSCH INJECTION-PUMP ASSEMBLY 9400616017 1016922491 220201210a


 

Information injection-pump assembly

BOSCH 9 400 616 017 9400616017
ZEXEL 101692-2491 1016922491
HINO 220201210A 220201210a
101692-2491 INJECTION-PUMP ASSEMBLY
Rating:
12
Buy INJECTION-PUMP ASSEMBLY 101692-2491 zexel genuine, new aftermarket engine parts with delivery

Include in #1:

Cross reference number

Zexel num
Bosch num
Firm num
Name
101692-2491 
9 400 616 017 
220201210A  HINO
INJECTION-PUMP ASSEMBLY
DK10 K 14BE INJECTION PUMP ASSY PE6A PE




Information:

Prior to stopping an engine that is being operated at low loads, run the engine at low idle for 30 seconds before stopping. But, if the engine is being operated at highway speeds and/or high loads, then it should be run at low idle for three minutes to reduce and stabilize internal engine temperature before stopping.To stop the engine, use the method listed that applies to the shutoff system on your truck.1. Turn the key switch to the OFF position, or2. ... pull OUT the manual shutoff control (if equipped), or3. ... push IN and hold the stop button until the engine stops, then release the button.Make sure the shutoff procedure is understood. Refer to the truck manufacturer's instructions for your type of engine shutoff system used. Fill the fuel tank at the end of each day of operation to drive out moist air and to prevent condensation. Do not fill the tank to the top. Fuel expands as it gets warm and may overflow.Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.

Have questions with 101692-2491?





Group cross 101692-2491 ZEXEL

Hino 

 
6071100601 

 
6061113101 

 
6061113102 

 
220202200A 

 
 

DS140
 
6071110231 
INJECTION-PUMP ASSEMBLY
EB100
 
220004011A 
INJECTION-PUMP ASSEMBLY
EB100
 
 
INJECTION-PUMP ASSEMBLY

Hino 

101692-2491  
9 400 616 017 
220201210A 
INJECTION-PUMP ASSEMBLY