101691-4330 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016914330 1156004690


 

Information injection-pump assembly

ZEXEL 101691-4330 1016914330
ISUZU 1156004690 1156004690
101691-4330 INJECTION-PUMP ASSEMBLY
Rating:
8
Buy INJECTION-PUMP ASSEMBLY 101691-4330 zexel genuine, new aftermarket engine parts with delivery

Service parts 101691-4330 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101069-3130
3. GOVERNOR 105472-0740
4. SUPPLY PUMP 105210-4251
5. AUTOM. ADVANCE MECHANIS 105612-0830
6. COUPLING PLATE 105662-0350
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-2010
11. Nozzle and Holder 9-15300-184-2
12. Open Pre:MPa(Kqf/cm2) 9.8{100}
13. NOZZLE-HOLDER 105031-2600
14. NOZZLE 105000-1130
15. NOZZLE SET

Include in #1:

101691-4330 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101691-4330 1016914330
ISUZU 1156004690 1156004690


Zexel num
Bosch num
Firm num
Name
101691-4330 
 
1156004690  ISUZU
INJECTION-PUMP ASSEMBLY
DH100 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   2.2 2.15 2.25
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.5 60.5
Difference between angles 2
Cyl.1-2
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cal 1-3
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-5
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   12.9
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   106 103.7 108.3
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   12.5
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   109.5 106 113
Max. variation between cylinders %   0 -3 3
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   6.5+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   10 7.7 12.3
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Timer adjustment
Pump speed r/min   400+-50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   600
Advance angle deg.   0.5 0 1
Timer adjustment_03
Pump speed r/min   900
Advance angle deg.   1.4 0.9 1.9
Timer adjustment_04
Pump speed r/min   1150
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101691-4330
N:Pump speed R:Rack position (mm) (1)Beginning of damper spring operation: DL (2)Set the load lever's stop position so that R = aa (N = 0). (3)RACK LIMIT: RAL
----------
DL=6-0.2mm aa=6mm RAL=12.9+0.2mm
----------

0000000901

Test data 101691-4330
F:Full load I:Idle S:Stop
----------

----------
a=3deg+-5deg b=11deg+-3deg c=42deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=275r/min Ra=6.5mm
----------




Information:

START BY:a. remove alternator and mounting groupb. remove water temperature regulator and manifold1. Drain the coolant from the engine. 2. Loosen the clamps on breather tube (1), and pull it back for clearance. 3. Remove bolt (2) from the cover on the side of the cylinder block. 4. Remove the three bolts that hold cover (3) to the water pump. Remove cover (3) from the water pump. 5. Remove the two bolts, and remove elbow (4) from bonnet (5). Remove the two bolts, and remove bonnet (5) from the water pump. It is not necessary to remove bolts (6). These bolts only hold the cover to the timing gear cover.6. Remove six long bolts (7) that hold the water pump to the timing gear cover. Remove water pump (8).Install Water Pump
1. Check the O-ring seals and gaskets, and make replacements if needed. 2. Make sure O-ring seal (1) is in position on the water pump. Put water pump (2) into position in the timing gear cover. Install the bolts that hold the water pump in place. 3. Make sure the gaskets are in place. Connect bonnet (3) to the water pump. Connect elbow (4) to the bonnet. 4. Make sure O-ring seal (5) is in position, and install cover (6) on the water pump. 5. Install bolt (7) on the cover on the side of the engine. 6. Put breather tube (8) in position, and install the clamps that hold it.7. Fill the cooling system to the correct level. See the Maintenance Guide.Disassemble Water Pump
START BY:a. remove water pump The water pump seal can be replaced without removing the water pump from the engine.An intermittent leakage of a small amount of coolant from the hole in the water pump housing is not an indication of a water pump seal failure. This is required to provide lubrication for the seal. Replace the water pump seal only if a large amount of leakage or a constant flow of coolant is observed draining from the water pump housing.1. Remove O-ring seal (1) from the adapter.2. Remove adapter (2) from the housing. Remove the O-ring seal from the outside diameter of the adapter.3. Remove bolt (3) and the retainer that hold the impeller on the shaft. 4. Use tooling (A) to remove impeller (4) from the shaft. 5. Remove the spring and seal (5) from the shaft. 6. Remove four bolts (7) from retainer (6) that hold the shaft assembly to the pump housing.7. Remove O-ring seal (8) from the housing. 8. Remove gear and shaft assembly (10) from the housing.9. Remove bolt (9) and the retainer from the shaft assembly. 10. Use a press to remove the shaft assembly from gear (11). Remove the retainer from the shaft assembly. 11. Remove bearing (13), spacer (14) and bearing (12) from the shaft. 12. Remove lip-type seal (15) from the housing.13. Turn the housing over, and remove ceramic ring (16) and the seal.Assemble Water Pump
1. Use 6V1541 Quick Cure Primer and clean shaft

Have questions with 101691-4330?





Group cross 101691-4330 ZEXEL

Isuzu 

 
1156000691 

DH100
 
9812010441 
INJECTION-PUMP ASSEMBLY
E110
 
9812011281 

E110
101691-4330  
 
1156004690 
INJECTION-PUMP ASSEMBLY
DH100
 
1156004350 
INJECTION-PUMP ASSEMBLY
DH100
 
1156004700 

DH100
 
1156004731 
INJECTION-PUMP ASSEMBLY
DH100
 
1156004710 
INJECTION-PUMP ASSEMBLY
DH100
 
1156004720 
INJECTION-PUMP ASSEMBLY
DH100
 
1156005580 
INJECTION-PUMP ASSEMBLY
DH100
Back to top