101681-9060 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016819060 16790z5501


 

Information injection-pump assembly

ZEXEL 101681-9060 1016819060
NISSAN-DIESEL 16790Z5501 16790z5501
101681-9060 INJECTION-PUMP ASSEMBLY
Rating:
73
Buy INJECTION-PUMP ASSEMBLY 101681-9060 zexel genuine, new aftermarket engine parts with delivery

Service parts 101681-9060 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101068-3810
3. GOVERNOR 105400-1530
4. SUPPLY PUMP 105220-5640
5. AUTOM. ADVANCE MECHANIS 105622-0440
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5240
11. Nozzle and Holder 16600-Z5508
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-4420
14. NOZZLE 105015-4730
15. NOZZLE SET

Include in #1:

101681-9060 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101681-9060 1016819060
NISSAN-DIESEL 16790Z5501 16790z5501


Zexel num
Bosch num
Firm num
Name
101681-9060 
 
16790Z5501  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
FD6T * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   2.4 2.35 2.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.5 60.5
Difference between angles 2
Cyl.1-2
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cal 1-3
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-5
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.7
Pump speed r/min   1350 1350 1350
Average injection quantity mm3/st.   76.7 75.3 78.1
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.7
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   72.7 70.7 74.7
Max. variation between cylinders %   0 -3 3
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   7.2+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   11.7 9.9 13.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Timer adjustment
Pump speed r/min   400+-50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   1.5 1 2
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   3 2.5 3.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101681-9060
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT: RAL (3)Set idle sub-spring (4)Damper spring setting: DL (5)Set the governor spring.
----------
K=13 RAL=14.5+-0.1mm DL=6.9-0.2mm
----------

Speed control lever angle

Test data 101681-9060
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=15deg+-5deg b=24deg+-5deg

Stop lever angle

Test data 101681-9060
N:Pump normal S:Stop the pump.
----------

----------
a=19deg+-5deg b=53deg+-5deg

Timing setting

Test data 101681-9060
(1)Pump vertical direction (2)Position of gear mark 'P' at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(50deg)




Information:


Repeat Steps 4 through 6 to remove (bleed) air from the rear table lift cylinder (not shown).
Open (CCW) hand pump control knob (11) to completely lower the DPF cleaner table. Close (CW) the hand pump control knob.
Illustration 38 g02728258
(28) Hydraulic Oil Level 51 to 102 mm (2.0 to 4.0 inch)
Check the oil level in the pump reservoir. Remove fill cap (13) located on the end cap of the hand pump. Hydraulic oil level (28) should be 51 to 102 mm (2.0 to 4.0 inch) from the bottom of the fill hole. Add high-grade hydraulic oil, if needed.Note: A clean wire tie can be used as a dipstick to measure the hydraulic oil level in the pump reservoir.Troubleshooting Guide
Table 3
Symptom     Solution    
Air dryer desiccant is a pinkish color.     1. Replace or regenerate the desiccant. Refer to ""Maintenance Section"".    
Bursting does not occur.     1. Check display screen for error message.
2. Check power connection to burst valve solenoid.    
Cabinet doors do not close correctly.     1. Look for damaged door hinges, seals, and latches.
2. Verify that vehicle sensors have been removed from DPF.    
Cabinet doors open during burst process.     1. Verify that doors are correctly latched.
2. Look for damage to door latches.
3. Check seals between DPF and adapters.    
Clamping force cannot be obtained.     1. Look for hydraulic fluid leaks.
2. Check fluid level in hydraulic pump. Refer to ""Maintenance Section"".    
Clamping force does not hold.     1. Upon initial clamping, it is possible for clamp load to drop
689 to 1379 kPa (99.9 to 200.0 psi) within the first minute, due to temperature effects. After reclamping, the drop should be virtually zero.
2. Look for hydraulic fluid leaks.    
Display screen is blank.     1. Verify that machine is ON, plugged into an outlet, and power is available to the outlet.
2. Reset circuit breakers located on left side of control cabinet.    
DPF does not line up correctly on the table.     1. Verify that correct adapters are being used.
2. Verify DPF is correctly seated on to lower adapter.    
DPF is damaged after cleaning process.     1. Check DPFs for damage before cleaning.
2. Look for damage on adapters.
3. Verify that correct cleaning protocol was entered into machine.    
DPF is not cleaned.     1. Check orientation of DPF. Refer to ""General Information"" Section.
2. Verify that correct cleaning protocol was entered into machine.
3. Look for other DPF conditions that may prevent successful cleaning.  

Have questions with 101681-9060?





Group cross 101681-9060 ZEXEL

Daewoo 

 
 
INJECTION-PUMP ASSEMBLY
6BB1

Nissan-Diesel 

 
16700Z5500 
INJECTION-PUMP ASSEMBLY
FD6T

Daewoo 

 
 
INJECTION-PUMP ASSEMBLY
6BB1
9 400 615 958 
 
INJECTION-PUMP ASSEMBLY
6BB1

Nissan-Diesel 

 
16700Z5504 
INJECTION-PUMP ASSEMBLY
FD6T
101681-9060  
 
16790Z5501 
INJECTION-PUMP ASSEMBLY
FD6T
 
16713Z5500 
INJECTION-PUMP ASSEMBLY
FD6T
 
16700Z5505 

FD6T
 
16700Z5506 

Back to top