101609-3020 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016093020 6136721250


 

Information injection-pump assembly

ZEXEL 101609-3020 1016093020
KOMATSU 6136721250 6136721250
101609-3020 INJECTION-PUMP ASSEMBLY
Rating:
27
Buy INJECTION-PUMP ASSEMBLY 101609-3020 zexel genuine, new aftermarket engine parts with delivery

Service parts 101609-3020 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-4020
3. GOVERNOR 105410-9200
4. SUPPLY PUMP 105210-4570
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105661-0371
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5870
11. Nozzle and Holder 6136-12-3200
12. Open Pre:MPa(Kqf/cm2) 22.1{225}
13. NOZZLE-HOLDER 105031-4480
14. NOZZLE 105015-5470
15. NOZZLE SET

Include in #1:

101609-3020 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101609-3020 1016093020
KOMATSU 6136721250 6136721250


Zexel num
Bosch num
Firm num
Name
101609-3020 
 
6136721250  KOMATSU
INJECTION-PUMP ASSEMBLY
6D105 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   9.3
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   47 46 48
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.2
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   53.6 49.6 57.6
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   8+-0.5
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   9.5 8.5 10.5
Max. variation between cylinders %   0 -10 10
Fixing the rack   *

Test data Ex:

Governor adjustment

Test data 101609-3020
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Rack difference between N = N1 and N = N2 (3)Rack difference between N = N3 and N = N4
----------
K=8 N1=1250r/min N2=800r/min N3=1250r/min N4=400r/min
----------

Speed control lever angle

Test data 101609-3020
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=6deg+-5deg b=23deg+-5deg

Stop lever angle

Test data 101609-3020
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at speed = aa and rack position = bb.
----------
aa=0r/min bb=1-0.2mm
----------
a=42.5deg+-5deg b=(55deg)

Timing setting

Test data 101609-3020
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(0deg)




Information:

Test Points (Voltages And Waveforms)
dc Voltages Conditions: 1. dc input voltage applied to POWER connector as shown.2. CALIBRATION CHECK/OPERATE switch in the OPERATE position.3. Neither transducer connected to indicator.4. TPI is reference for all voltages.Equipment Required: 6V3030 Digital Multimeterdc Input Voltages Waveforms Conditions: 1. dc power input voltage of 25 1 Volts.2. CALIBRATION CHECK/OPERATE switch in the CHECK position (can be held in CHECK position with tape).3. Neither transducer connected to indicator.4. TPI is reference for all waveforms.Equipment Required: dc oscilloscope (dual channel preferred). Waveform Time Relationships
VOLTAGES MAY VARY 10%, PULSE DURATIONS BY 20% EXCEPT 2.66 ms WHICH IS BASED ON A 12.000 kHz OSCILLATOR FREQ. (1C202). SIGNAL SOURCE IS INTERNAL CALIBRATOR. ALL TEST POINTS REFERENCED TO TP1.Waveform Time Relationships (enlarged scale)
VOLTAGES MAY VARY 10%, PULSE DURATIONS BY 20% EXCEPT 83.3 ?s AND 2.66 ms WHICH ARE EXACT BASED ON A 12.000 kHZ OSCILLATOR. (1C202) SIGNAL SOURCE IS INTERNAL CALIBRATOR. ALL TEST POINTS REFERENCED TO TP1.Disassembly Procedure
1 Remove six screws (1) from front panel (2), and remove panel (2) from case (3). Remove four screws (4) from the PC board, and also remove the locknuts from the two front panel switches (5) and (6). Carefully lift front panel (2) from PC (printed circuit) board (7).Calibration Procedure
To make sure the 6V3100 Timing Indicator Group (1) has good accuracy, check its calibration at a minimum of every six months. Also, the timing indicator will need calibration if: A. It does not show 2000 30 R/MIN at (A) and 32.0 .2 DEG at (B), when the CALIBRATION CHECK-OPERATE Switch (C) is in the CALIBRATION CHECK position. With no input signal at (D) or (E), the reading at R/MIN location (A) must show three zeros (000). If four zeros (0000) show, it is an indication of a possible need for calibration of the unit. This error only is not reason enough to do a complete calibration procedure. It is also not necessary to do a complete calibration procedure if the reading at the DEG location (B) has a decimal point as shown, (00.0) in addition to the three zeros.B. Reading is different than (000) at either location (A) or (B).All calibrations can be done with the use of a small screwdriver, a frequency counter and

Have questions with 101609-3020?





Group cross 101609-3020 ZEXEL

Komatsu 

9 400 619 825 
6221711320 
INJECTION-PUMP ASSEMBLY
S6D108
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 610 771 
6221711940 
INJECTION-PUMP ASSEMBLY
S6D108
101609-3020  
 
6136721250 
INJECTION-PUMP ASSEMBLY
6D105
9 400 611 661 
6137721431 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 611 523 
6137721441 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 611 444 
6137721451 
INJECTION-PUMP ASSEMBLY
S6D105
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 612 306 
6209721210 
INJECTION-PUMP ASSEMBLY
SA6D95L
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 615 887 
6209721310 
INJECTION-PUMP ASSEMBLY
SA6D95L
9 400 615 888 
6221711220 
INJECTION-PUMP ASSEMBLY
S6D108
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 611 445 
6221711210 
INJECTION-PUMP ASSEMBLY
S6D108
Back to top