101609-3010 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016093010


 

Information injection-pump assembly

ZEXEL 101609-3010 1016093010
101609-3010 INJECTION-PUMP ASSEMBLY
Rating:
24
Buy INJECTION-PUMP ASSEMBLY 101609-3010 zexel genuine, new aftermarket engine parts with delivery

Service parts 101609-3010 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101061-8380
3. GOVERNOR 105419-0720
4. SUPPLY PUMP 105210-5040
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5260
11. Nozzle and Holder 6221-11-3200
12. Open Pre:MPa(Kqf/cm2) 26.0{265}
13. NOZZLE-HOLDER 105048-3560
14. NOZZLE 105017-1120
15. NOZZLE SET

Include in #1:

101609-3010 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101609-3010 1016093010


Zexel num
Bosch num
Firm num
Name
101609-3010 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   8.3
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   115.5 114.5 116.5
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the rack   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   8.9
Pump speed r/min   885 885 885
Average injection quantity mm3/st.   131.4 129.4 133.4
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   5.1+-0.5
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   16.4 15.2 17.6
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Injection quantity adjustment_04
Adjusting point   F
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   218 208 228
Fixing the lever   *
Rack limit   *

Test data Ex:

Governor adjustment

Test data 101609-3010
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT (3)Idle sub spring setting: L1.
----------
K=8 L1=4.9-0.5mm
----------

Speed control lever angle

Test data 101609-3010
F:Full speed I:Idle (1)Set the pump speed at aa (2)Stopper bolt setting (3)Set the pump speed at bb (at delivery)
----------
aa=750r/min bb=900r/min
----------
a=5deg+-5deg b=1deg+-5deg c=19deg+-5deg

Stop lever angle

Test data 101609-3010
N:Pump normal S:Stop the pump. (1)No return spring
----------

----------
a=6.5deg+-5deg b=53deg+-5deg

Timing setting

Test data 101609-3010
(1)Pump vertical direction (2)Position of camshaft's key groove at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(50deg)




Information:

4. Install a new seal washer (6).Use 6V-4979 Carbon Stop Seal Tool (4) to install new carbon dam (5) on nozzle (2).7000 Series Nozzles
The part number for compression seal (3) is not the same for all nozzles. If the correct seal is not installed, the result will be high emissions. This is NOT acceptable.
Troubleshooting (Pencil-Type Fuel Nozzles Only)
A. To troubleshoot these nozzles, refer to the Troubleshooting Guide For Pencil-Type Fuel Nozzles located in this manual.B. Refer to Special Instruction SEHS8627 "Use of 8S-2245 Nozzle Cleaning Tool Group" for the correct procedure (according to the part number of the nozzle) in order to clean these nozzles. C. If VO is LESS than the specified value for a specific part number, DO NOT use the nozzle.Troubleshooting Guide For Pencil-Type Fuel Nozzles
Troubleshooting Guide For Caterpillar 7000 Series Direct Injection Fuel Nozzles
Engine Nozzle Test Record Form (Sample Copy)
Repair/Calibration Information For 5P-4150 Tester Group
For the repair and/or calibration of the 5P-4150 Tester Group, contact the manufacturer: U.S. Mail:OTC Division
SPX Corporation
655 Eisenhower Drive
Owatonna, Minnesota 55060, U.S.A.
Telephone:(507) 455-7000(800) 533-6127 Fax:(800) 955-8329Test Equipment Calibration
Caterpillar fuel nozzle and unit injector testers feature premium quality, liquid filled gauges for high accuracy and durability.Pressure gauges, in this application must be of high quality in order to provide accurate and consistent test results.To maintain this high degree of accuracy, gauge calibration should be checked at a MINIMUM of once a year. Additional information can be found in NEHS0631 "General Maintenance And Troubleshooting For Fuel Injection Equipment Test Stands (FIETS) And 5P-4150 Nozzle Tester". However, calibration should be checked at any time when the test results have become INCONSISTENT or if the gauge needle does NOT return to the 0 (zero) range when the test pressure is relieved.Calibration
Two methods are available for gauge calibration:* Method 1: Calibration by gauge manufacturer.* Method 2: 5P-8558 Pressure Gauge Calibrating Group. Additional information can be found in NEHS0631 "General Maintenance And Troubleshooting For Fuel Injection Equipment Test Stands (FIETS) And 5P-4150 Nozzle Tester".Calibration By Gauge Manufacturer (Method 1)
Certified calibration services are offered by Carrier - Oehler Company, a Caterpillar certified supplier of premium quality gauges.The Carrier - Oehler Company can promptly check and recalibrate gauges at a low cost.The Carrier - Oehler Company will also repair and recalibrate damaged gauges at a fraction of the cost of a new gauge.When sending gauges to Carrier - Oehler Company, include the following information:* Person or department that gauges and/or correspondence is to be directed to.* List the quantity and a brief description of the gauge(s) problem or the service requested.* Dealer name and address.* Telephone number.* Fax number. The Carrier - Oehler Company will advise you if repair costs exceed 50 percent of a new gauge. Questions on costs, service, and repair time should be directed to the Caterpillar Repair Desk:(800) 321-3241 Shipping:Carrier - Oehler Company
16965 Vincennes Avenue
South Holland, Illinois 60473
U.S. Mail:Carrier - Oehler Company
Post Office Box 40
16965 Vincennes Avenue
South Holland, Illinois 60473
Telephone:(708) 339-8200 Fax:(708) 339-98305P-8558 Pressure Gauge Calibrating Group (Method 2)
(1) 5P-0946 Box Assembly.(2) 1P-2375 Quick

Have questions with 101609-3010?





Group cross 101609-3010 ZEXEL

Komatsu 

9 400 619 825 
6221711320 
INJECTION-PUMP ASSEMBLY
S6D108
101609-3010  
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 610 771 
6221711940 
INJECTION-PUMP ASSEMBLY
S6D108
 
6136721250 
INJECTION-PUMP ASSEMBLY
6D105
9 400 611 661 
6137721431 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 611 523 
6137721441 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 611 444 
6137721451 
INJECTION-PUMP ASSEMBLY
S6D105
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 612 306 
6209721210 
INJECTION-PUMP ASSEMBLY
SA6D95L
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 615 887 
6209721310 
INJECTION-PUMP ASSEMBLY
SA6D95L
9 400 615 888 
6221711220 
INJECTION-PUMP ASSEMBLY
S6D108
 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 611 445 
6221711210 
INJECTION-PUMP ASSEMBLY
S6D108
Back to top