101607-6825 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1016076825


 

Information injection-pump assembly

ZEXEL 101607-6825 1016076825
101607-6825 INJECTION-PUMP ASSEMBLY
Rating:
20
Buy INJECTION-PUMP ASSEMBLY 101607-6825 zexel genuine, new aftermarket engine parts with delivery

Service parts 101607-6825 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101061-8851
3. GOVERNOR 105932-0514
4. SUPPLY PUMP 105210-6020
5. AUTOM. ADVANCE MECHANIS 105672-5230
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-7183
11. Nozzle and Holder ME075761
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/21.6{220}
13. NOZZLE-HOLDER 105041-3031
14. NOZZLE
15. NOZZLE SET 105019-0371

Include in #1:

101607-6825 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

Zexel num
Bosch num
Firm num
Name
101607-6825 
 
   
INJECTION-PUMP ASSEMBLY




Information:

Events
The events are used in order to record a problem that is detected by the control system. Events are also used to document adverse engine operation. Events will be communicated to the service tool via the CDL. An event indicates that the control system has detected an engine problem. An event does not indicate an electronic problem. For example, the high exhaust temperature event is disabled if a problem with the temperature sensor is detected. (Events can be configured to be triggered on a diagnostic.)An event is identified by a numerical code. The EID (Event Identifier) identifies an engine problem or a problem with the machine. The service tool is used to display the EID. The service tool adds descriptive text for each EID in order to avoid mistakes in interpreting the codes.Logged Events
When an event is activated, information about the event is logged into permanent memory for the Electronic Control Module. The CDL can then request this information from the ECM. The CDL will display the following information for each logged event. Up to twenty five different events can be logged. Events are not automatically erased.
EID
FMI
Description of the event
Number of occurrences
The first time of occurrence
The last time of occurrenceEvents may be cleared from the memory of the ECM in order to use the CDL. Logged events can be configured so that a factory password is required to clear the event. Table 1 references the Event Codes that can be seen in order to use the Diesel Particulate Filter Monitor System.
Table 1
EID     Description     Security Level    
194     Warning for the High Exhaust Temperature     1    
194     Critical Warning for the High Exhaust Temperature     2    
1049     Warning for the Pressure Inlet for the High Particulate Trap     1    
1049     Critical Warning for the Pressure Inlet for the High Particulate Trap     2    