101607-6815 ZEXEL 9 400 610 716 BOSCH INJECTION-PUMP ASSEMBLY 9400610716 1016076815 me075572


 

Information injection-pump assembly

BOSCH 9 400 610 716 9400610716
ZEXEL 101607-6815 1016076815
MITSUBISHI ME075572 me075572
101607-6815 INJECTION-PUMP ASSEMBLY
Rating:
14
Buy INJECTION-PUMP ASSEMBLY 101607-6815 zexel genuine, new aftermarket engine parts with delivery

Service parts 101607-6815 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101061-8851
3. GOVERNOR 105932-0503
4. SUPPLY PUMP 105210-6020
5. AUTOM. ADVANCE MECHANIS 105672-5220
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-7460
11. Nozzle and Holder ME075788
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/21.6{220}
13. NOZZLE-HOLDER 105041-3030
14. NOZZLE
15. NOZZLE SET 105019-0361

Include in #1:

101607-6815 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 610 716 9400610716
ZEXEL 101607-6815 1016076815
MITSUBISHI ME075572 me075572


Zexel num
Bosch num
Firm num
Name
101607-6815 
9 400 610 716 
ME075572  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D16 K 14BF INJECTION PUMP ASSY PE6AD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8420
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.7
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   78 75.7 80.3
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   10+-0.5
Pump speed r/min   480 480 480
Each cylinder's injection qty mm3/st.   21.8 18.5 25.1
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.7)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   78 77 79
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.25
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   82.5 78.5 86.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.55
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   51.5 47.5 55.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   115 115 135
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   950--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   900
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   -
Advance angle deg.   1 0.5 1.5
Remarks
Measure the actual speed.
 
Timer adjustment_04
Pump speed r/min   1200
Advance angle deg.   1 0.5 1.5
Timer adjustment_05
Pump speed r/min   1450
Advance angle deg.   7 6.5 7.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-6815
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=M13
----------

Speed control lever angle

Test data 101607-6815
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=40mm
----------
a=26.5deg+-5deg b=(43.5deg)+-3deg

Stop lever angle

Test data 101607-6815
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at pump speed = aa and rack position = bb (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (non-injection rack position). (3)Rack position = approximately ee (speed lever full, speed = ff). (4)Free (at delivery)
----------
aa=1450r/min bb=7.2-0.5mm cc=275r/min dd=(8.8)mm ee=15mm ff=0r/min
----------
a=36.5deg+-5deg b=(25deg) c=13deg+-5deg

0000001501 LEVER

Test data 101607-6815
(A) Idle (B) Full speed (C) Base lever (D) Accelerator lever (E) Accelerator lever delivery position 1. Measure speed lever angle (1)Measure the angle when the accelerator lever (D) contacted the base lever (C) at a.
----------

----------
b=(43.5deg)+-3deg c=26.5deg+-5deg

Timing setting

Test data 101607-6815
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=7deg
----------
a=(4deg)




Information:


Table 1
Service Tools    
Part Number    Part    
    Caterpillar Electronic Technician (ET)    
6V-7070
9U-7330     Digital Multimeter    
8T-3224     Needle Tip Group    
7X-1710     Multimeter Probe Group    
8T-8726     Adapter Cable Assembly    
9U-7246     Connector Repair Kit
DT    
4C-3406     Connector Repair Kit    
4C-8195     Control Service Tool (Switch Box)    
Illustration 1 g00774942
Connections for the Communication Adapter II and the Caterpillar Electronic Technician (ET)The components that are needed in order to use the Communication Adapter II and the Caterpillar Electronic Technician ( ET) in order to determine diagnostic codes are listed: (6) Cable (7) 171-4400 Communication Adapter II (8) Service diagnostic cable. (9) Current version of Cat ET software and an IBM-COMPATIBLE personal computerReferenceSee Special Publication, NEHS0758, "Communications Adapter II User's Manual Contains Software".Note: Caterpillar Electronic Technician (ET) is a software program that can be used on an IBM compatible personal computer. In order to use the Cat ET, order the following materials: Special Publication, JERD2124, "ET Single Use Program License", Special Publication, JEHP1026, "Information and Requirements Sheet", 7X-1425 Data Link Cable and the Data Subscription and Special Publication, JERD2142, "Data Subscription". The Special Publication, JEHP1026, "Information and Requirements Sheet" lists the required hardware and the features of the Cat ET.The Cat ET is not required in order to determine the diagnostic codes and the Cat ET is not required in order to clear the diagnostic codes. However, the process of determining the diagnostic codes is easier and faster by using the Cat ET. The Cat ET can also display information on the history of a diagnostic code and the parameter status of diagnostic codes. These features allow the Cat ET to be a useful tool for troubleshooting.The Cat ET is used to communicate to the electronic control module over the data link by connecting to the machine diagnostic connector. For more information and the locations of the connectors, see Troubleshooting, "Electrical Components and Connector Locations" and the Electrical System Schematic in your machine's Service Manual.For instructions on servicing Sure Seal connectors, see Special Instruction, SMHS7531. For instructions on servicing Deutsch connectors, see Special Instruction, SEHS9615.Use the digital multimeter for measuring resistance or for measuring voltage. For instructions about the use of the 6V-7070 Digital Multimeter, see Special Instruction, SEHS7734. The 7X-1710 Multimeter Probe measures the voltage at the connectors without disconnecting the connectors. The probe cables are pushed into the back of the connector along the wire. The 8T-8726 Adapter Cable has a breakout with 3 pins. The adapter cable is used for measurements in the sensor circuits.Note: Except for harness tests, using continuity testers such as the 8T-0500 Continuity Tester or voltage testers such as the 5P-7277 Voltage Tester is not recommended for today's Caterpillar electrical circuits.

Have questions with 101607-6815?





Group cross 101607-6815 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

101607-6815  
9 400 610 716 
ME075572 
INJECTION-PUMP ASSEMBLY
6D16
Back to top