101607-6352 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016076352


 

Information injection-pump assembly

ZEXEL 101607-6352 1016076352
101607-6352 INJECTION-PUMP ASSEMBLY
Rating:
25
Buy INJECTION-PUMP ASSEMBLY 101607-6352 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

ZEXEL 101607-6352 1016076352


Zexel num
Bosch num
Firm num
Name
101607-6352 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8420
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.3
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   101.8 98.7 104.9
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   600 600 600
Each cylinder's injection qty mm3/st.   11.5 9.8 13.2
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.3)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   101.8 100.8 102.8
Basic   *
Fixing the lever   *
Boost pressure kPa   36 36
Boost pressure mmHg   270 270
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+1
Pump speed r/min   1350 1350 1350
Average injection quantity mm3/st.   117.9 113.9 121.9
Fixing the lever   *
Boost pressure kPa   36 36
Boost pressure mmHg   270 270
Injection quantity adjustment_05
Adjusting point   C
Rack position   R2(R1-0. 4)
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   92.6 88.6 96.6
Fixing the lever   *
Boost pressure kPa   36 36
Boost pressure mmHg   270 270
Injection quantity adjustment_06
Adjusting point   E
Rack position   R1+0.7
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   113.5 109.5 117.5
Fixing the lever   *
Boost pressure kPa   36 36
Boost pressure mmHg   270 270
Injection quantity adjustment_07
Adjusting point   F
Rack position   (R2-0.75 )
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   48.2 46.2 50.2
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   500 500 500
Rack position   (R2-0.75 )
Boost pressure kPa   3.3 2 4.6
Boost pressure mmHg   25 15 35
Boost compensator adjustment_02
Pump speed r/min   500 500 500
Rack position   R2(R1-0. 4)
Boost pressure kPa   22.7 22.7 22.7
Boost pressure mmHg   170 170 170
Timer adjustment
Pump speed r/min   1150--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1100
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1340
Advance angle deg.   3.5 3 4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-6352
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Boost compensator stroke: BCL
----------
T1=H52 BCL=(0.75)+-0.1mm
----------

Speed control lever angle

Test data 101607-6352
F:Full speed I:Idle (1)Accelerator lever (2)Use the hole at R = aa (3)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=41deg+-5deg b=(42deg)+-3deg

Stop lever angle

Test data 101607-6352
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at pump speed = aa and rack position = bb (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (non-injection rack position).
----------
aa=1350r/min bb=7-0.5mm cc=275r/min dd=(8)mm
----------
a=25deg+-5deg b=27deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

Timing setting

Test data 101607-6352
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(0deg)




Information:


Table 2
Specifications for Pressure Loss
Direct Injection Fuel Systems    
Nozzle pressure must not drop below a gauge reading of
3450 kPa (500 psi) during a 5 second time interval.    
Nozzle pressure must drop below a gauge reading of
1380 kPa (200 psi) after an additional 25 second time interval. (1)    
( 1 ) A gauge reading of 0 kPa (0 psi) is acceptable after the first 5 second time interval has elapsed.
Illustration 3 g00923167
If the fuel nozzle is not within specifications, stop the test and do not use the fuel nozzle.Valve Opening Pressure Test
Slowly increase the pressure until fluid begins to flow from the tip of the fuel nozzle. Record this pressure as the VOP of the fuel nozzle.
Compare the test results to the specifications for the type of fuel nozzle that is being tested. Refer to Table 3, or Table 4.For precombustion chamber fuel systems, use these specifications:
Table 3
Specifications for Valve Opening Pressure
Precombustion Chamber Fuel Systems    
2760 to 5170 kPa (400 to 750 psi)    
Illustration 4 g00934108
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.For direct injection fuel systems, use these specifications:
Table 4
Specifications for Valve Opening Pressure
Direct Injection Fuel Systems    
16500 to 21400 kPa (2400 to 3100 psi)    
Illustration 5 g00923174
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.Tip Leakage Test (Direct Injection Fuel Systems)
Note: Fuel nozzles for precombustion chamber fuel systems can not be tested for tip leakage accurately. Do not perform this test on fuel nozzles for a precombustion

Have questions with 101607-6352?





Group cross 101607-6352 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 691 
ME076360 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 692 
ME076424 
INJECTION-PUMP ASSEMBLY
6D17
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 693 
ME076396 
INJECTION-PUMP ASSEMBLY
6D17
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
101607-6352  
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 694 
ME076397 
INJECTION-PUMP ASSEMBLY
6D15T3
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 610 710 
ME076417 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 695 
ME046050 
INJECTION-PUMP ASSEMBLY
6D16TL
F 019 Z10 390 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 391 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 696 
ME086721 
INJECTION-PUMP ASSEMBLY
6D31T
9 400 615 697 
ME046025 
INJECTION-PUMP ASSEMBLY
6D14T
Back to top