101607-6043 ZEXEL 9 400 615 665 BOSCH INJECTION-PUMP ASSEMBLY 9400615665 1016076043 me076920


 

Information injection-pump assembly

BOSCH 9 400 615 665 9400615665
ZEXEL 101607-6043 1016076043
MITSUBISHI ME076920 me076920
101607-6043 INJECTION-PUMP ASSEMBLY
Rating:
30
Buy INJECTION-PUMP ASSEMBLY 101607-6043 zexel genuine, new aftermarket engine parts with delivery

Include in #1:

Cross reference number

BOSCH 9 400 615 665 9400615665
ZEXEL 101607-6043 1016076043
MITSUBISHI ME076920 me076920


Zexel num
Bosch num
Firm num
Name
101607-6043 
9 400 615 665 
ME076920  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D15T3 K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8420
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
RED3 control unit part number   407910-2 470
RED3 rack sensor specifications mm   15
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Rack position   (12.4)
Vist V   1.52 1.52 1.52
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   113.4 111.4 115.4
Max. variation between cylinders %   0 -3 3
Basic   *
Injection quantity adjustment_02
Rack position   (9.5)
Vist V   2.1 2 2.2
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   11.5 9.8 13.2
Max. variation between cylinders %   0 -15 15

Test data Ex:

Governor adjustment

Test data 101607-6043
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C3=(8deg) t1=2--sec. t2=2--sec.
----------
N1=1400r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=0.5--deg C2=8+-0.3deg R01=4/4load R02=4/4load

Speed control lever angle

Test data 101607-6043
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=16mm bb=1mm
----------
a=29deg+-5deg b=2deg+-5deg

0000000901

Test data 101607-6043
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=9deg
----------
a=(1deg)

Stop lever angle

Test data 101607-6043
(Rs) rack sensor specifications (C/U) control unit part number (V) Rack sensor output voltage (R) Rack position (mm) 1. Confirming governor output characteristics (rack 15 mm, span 6 mm) (1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------

----------




Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The "FLT" LED is illuminated and the outputs of the controller are de-energized. The power to a chassis is lost.The red "FLT" LED is illuminated. There is a fatal error. A fatal error indicates that the processor is not communicating.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The green "RS232" LED is illuminated in the DH+ mode. The communications active bit (S:17) is set in the "System Status" file. The processor is communicating on the network.The green "RS232" LED is flashing in the DH+ mode. The processor cannot establish communication because there are no active nodes on the network.The "RS232" LED is extinguished in the DH+ mode. A fatal error is present.
Illustration 1 g00563574
Diagram of the LED indicators
Illustration 2 g00563507
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Proceed to 3.
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Refer to Maintenance Procedure, "Processor - Replace". Stop.

Have questions with 101607-6043?





Group cross 101607-6043 ZEXEL

F 01G 09U 05F 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 661 
ME076911 
INJECTION-PUMP ASSEMBLY
6D16T
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 662 
ME076917 
INJECTION-PUMP ASSEMBLY
6D15T2
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 663 
ME076919 
INJECTION-PUMP ASSEMBLY
6D17
9 400 615 664 
ME047931 
INJECTION-PUMP ASSEMBLY
6D16T
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

101607-6043  
9 400 615 665 
ME076920 
INJECTION-PUMP ASSEMBLY
6D15T3
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 666 
ME076988 
INJECTION-PUMP ASSEMBLY
6D15T3
F 019 Z10 371 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 372 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 373 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 667 
ME076989 
INJECTION-PUMP ASSEMBLY
6D15T3
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 668 
ME076990 
INJECTION-PUMP ASSEMBLY
6D16
F 01G 09U 05G 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 669 
ME076994 
INJECTION-PUMP ASSEMBLY
6D16
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 670 
ME076993 
INJECTION-PUMP ASSEMBLY
6D16
Back to top