101607-6040 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1016076040


 

Information injection-pump assembly

ZEXEL 101607-6040 1016076040
101607-6040 INJECTION-PUMP ASSEMBLY
Rating:
27
Buy INJECTION-PUMP ASSEMBLY 101607-6040 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
101607-6040 
 
   
INJECTION-PUMP ASSEMBLY




Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The green "RUN" LED is illuminated. The processor is in the "RUN" mode.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.The amber "FORCE" LED is illuminated. The forces are enabled.The amber "FORCE" LED is not illuminated. No forces are present or no forces are enabled.
Illustration 1 g00563544
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Clear the fault.
Place the switch in the PROG position.
Place the switch in the RUN position.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Refer to Maintenance Procedure, "Processor - Replace".

Have questions with 101607-6040?





Group cross 101607-6040 ZEXEL

F 01G 09U 05F 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 661 
ME076911 
INJECTION-PUMP ASSEMBLY
6D16T
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 662 
ME076917 
INJECTION-PUMP ASSEMBLY
6D15T2
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 663 
ME076919 
INJECTION-PUMP ASSEMBLY
6D17
9 400 615 664 
ME047931 
INJECTION-PUMP ASSEMBLY
6D16T
101607-6040  
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 665 
ME076920 
INJECTION-PUMP ASSEMBLY
6D15T3
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 666 
ME076988 
INJECTION-PUMP ASSEMBLY
6D15T3
F 019 Z10 371 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 372 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 373 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 667 
ME076989 
INJECTION-PUMP ASSEMBLY
6D15T3
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 668 
ME076990 
INJECTION-PUMP ASSEMBLY
6D16
F 01G 09U 05G 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 669 
ME076994 
INJECTION-PUMP ASSEMBLY
6D16
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 670 
ME076993 
INJECTION-PUMP ASSEMBLY
6D16
Back to top