101607-1151 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016071151


 

Information injection-pump assembly

ZEXEL 101607-1151 1016071151
101607-1151 INJECTION-PUMP ASSEMBLY
Rating:
84
Buy INJECTION-PUMP ASSEMBLY 101607-1151 zexel genuine, new aftermarket engine parts with delivery

Service parts 101607-1151 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101061-9500
3. GOVERNOR 105931-7650
4. SUPPLY PUMP 105210-4641
5. AUTOM. ADVANCE MECHANIS 105643-0680
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/21.6{220}
13. NOZZLE-HOLDER 105030-4110
14. NOZZLE
15. NOZZLE SET

Include in #1:

101607-1151 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101607-1151 1016071151


Zexel num
Bosch num
Firm num
Name
101607-1151 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.2
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   57.7 56 59.4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   13.7 11.6 15.8
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.2)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   57.7 56.7 58.7
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.1
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   72.6 68.6 76.6
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.8
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   59.7 55.7 63.7
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   R1+1.25
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   57.1 53.1 61.1
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   140 130 150
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1400
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-1151
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=F21
----------

Speed control lever angle

Test data 101607-1151
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=29mm
----------
a=24deg+-5deg b=41deg+-3deg

Stop lever angle

Test data 101607-1151
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at pump speed = aa and rack position = bb (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed = cc. Rack position = actual (non-injection rack position).
----------
aa=1550r/min bb=7-0.5mm cc=275r/min
----------
a=11.5deg+-5deg b=26deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

0000001601 LEVER

Test data 101607-1151
(A) Idle (B) Full speed (C) Base lever (D) Accelerator lever (E) Accelerator lever delivery position 1. Measure speed lever angle (1)Measure the angle when the accelerator lever (D) contacted the base lever (C) at a.
----------

----------
b=41deg+-3deg c=24deg+-5deg

Timing setting

Test data 101607-1151
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=13deg
----------
a=(0deg)




Information:


This engine may be equipped with a 12 or 24 volt starting system. Use only equal voltage for boost starting. The use of a welder or higher voltage will damage the electrical system.
Charging System Components
Alternator
The alternator is driven by belts from the crankshaft pulley. This alternator is a three phase, self-rectifying charging unit, and the regulator is part of the alternator.This alternator design has no need for slip rings or brushes, and the only part that has movement is the rotor assembly. All conductors that carry current are stationary. The conductors are: the field winding, stator windings, six rectifying diodes, and the regulator circuit components.The rotor assembly has many magnetic poles like fingers with air space between each opposite pole. The poles have residual magnetism (like permanent magnets) that produce a small amount of magnetic lines of force (magnetic field) between the poles. As the rotor assembly begins to turn between the field winding and the stator windings, a small amount of alternating current (AC) is produced in the stator windings from the small magnetic lines of force made by the residual magnetism of the poles. This AC current is changed to direct current (DC) when it passes through the diodes of the rectifier bridge. Most of this current goes to charge the battery and to supply the low amperage circuit, and the remainder is sent on to the field windings. The DC current flow through the field windings (wires around an iron core) now increases the strength of the magnetic lines of force. These stronger lines of force now increase the amount of AC current produced in the stator windings. The increased speed of the rotor assembly also increases the current and voltage output of the alternator.The voltage regulator is a solid state (transistor, stationary parts) electronic switch. It feels the voltage in the system and switches on and off many times a second to control the field current (DC current to the field windings) for the alternator to make the needed voltage output.
Never operate the alternator without the battery in the circuit. Making or breaking an alternator connection with heavy load on the circuit can cause damage to the regulator.
Alternator Components
(1) Regulator. (2) Roller bearing. (3) Stator winding. (4) Ball bearing. (5) Rectifier bridge. (6) Field winding. (7) Rotor assembly. (8) Fan.Starting System Components
Solenoid
Typical Solenoid SchematicA solenoid is a magnetic switch that does two basic operations.a. Closes the high current starting motor circuit with a low current start switch circuit.b. Engages the starting motor pinion with the ring gear.The solenoid switch is made of an electromagnet (one to two sets of windings) around a hollow cylinder. There is a plunger (core) with a spring load inside the cylinder that can move forward and backward. When the start switch is closed and electricity is sent through the windings, a magnetic field is made that pulls the plunger forward in the cylinder. This moves the shift lever (connected to the rear of the plunger) to engage the pinion

Have questions with 101607-1151?





Group cross 101607-1151 ZEXEL

F 01G 09U 050 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 590 
ME076611 
INJECTION-PUMP ASSEMBLY
6D16
F 01G 09U 051 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 052 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 591 
ME076658 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 592 
ME056882 
INJECTION-PUMP ASSEMBLY
6D22
9 400 615 593 
ME157300 
INJECTION-PUMP ASSEMBLY
6D22
F 01G 09U 053 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 054 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 594 
ME076617 
INJECTION-PUMP ASSEMBLY
6D16
101607-1151  
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 595 
ME076616 
INJECTION-PUMP ASSEMBLY
6D14
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 596 
ME076624 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 597 
ME076656 
INJECTION-PUMP ASSEMBLY
6D14
 
ME076669 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 598 
ME086626 
INJECTION-PUMP ASSEMBLY
6D31
Back to top