101606-0212 ZEXEL 9 400 612 115 BOSCH INJECTION-PUMP ASSEMBLY 9400612115 1016060212 8943922193


 

Information injection-pump assembly

BOSCH 9 400 612 115 9400612115
ZEXEL 101606-0212 1016060212
ISUZU 8943922193 8943922193
101606-0212 INJECTION-PUMP ASSEMBLY
Rating:
17
Buy INJECTION-PUMP ASSEMBLY 101606-0212 zexel genuine, new aftermarket engine parts with delivery

Service parts 101606-0212 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-6571
3. GOVERNOR 105932-3560
4. SUPPLY PUMP 105230-1090
5. AUTOM. ADVANCE MECHANIS 105690-0261
6. COUPLING PLATE 105661-1170
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-7743
11. Nozzle and Holder 8-94391-291-4
12. Open Pre:MPa(Kqf/cm2) 16.2{165}/19.6{200}
13. NOZZLE-HOLDER 105041-2082
14. NOZZLE
15. NOZZLE SET 105019-2190

Include in #1:

101606-0212 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

BOSCH 9 400 612 115 9400612115
ZEXEL 101606-0212 1016060212
ISUZU 8943922193 8943922193


Zexel num
Bosch num
Firm num
Name
101606-0212 
9 400 612 115 
8943922193  ISUZU
INJECTION-PUMP ASSEMBLY
6HH1 K 14BF INJECTION PUMP ASSY PE6AD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8260
Bosch type code   9 430 610 133
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   18
Opening pressure kgf/cm2   184
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8620
Overflow valve opening pressure kPa   206 172 240
Overflow valve opening pressure kgf/cm2   2.1 1.75 2.45
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.8 3.75 3.85
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   14.1
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   126 124.4 127.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   15.5 14.2 16.8
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(14.1)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   126 125 127
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   (R1+1.55 )+0.05-0 .15
Pump speed r/min   1425 1425 1425
Average injection quantity mm3/st.   137.5 134.3 140.7
Fixing the lever   *

Test data Ex:

Governor adjustment

Test data 101606-0212
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=N91
----------

Timer adjustment

Test data 101606-0212
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C2=(8)deg t1=2--sec. t2=2--sec.
----------
N1=1300++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 101606-0212
F:Full speed I:Idle (1)Stopper bolt set position 'H' (2)Use the pin at R = aa (3)Viewed from feed pump side.
----------
aa=35mm
----------
a=10deg+-5deg b=40.5deg+-3deg

Stop lever angle

Test data 101606-0212
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=45mm
----------
a=12.5deg+-5deg b=40deg+-5deg

0000001501 RACK SENSOR

Test data 101606-0212
Rack sensor adjustment 1. Flange type rack sensor (rack sensor adjustment -5*20) (1)These types of rack sensors do not need adjustment. Confirm the performance with the following procedures. (2)Mount the rack sensor main body to the pump main body. (3)Fix the pump lever at full. (4)At supply voltage V1, pump speed N1 and rack position Ra, confirm that the amp's output voltage is Vist. (5)Move the pump lever two or three times. (6)Set again to full. (7)Confirm that the amplifier output voltage is Vist. (8)Fix the caution plate to the upper part of the rack sensor. (For those without the caution plate instructions, make sure the nameplate of the rack sensor carries the "Don't hold here" caution.) (9)Apply red paint to the rack sensor mounting bolts (2 places).
----------
V1=5+-0.01V N1=850r/min Ra=R1(14.1)mm Vist=3.55+-0.28V
----------

Timing setting

Test data 101606-0212
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=7deg
----------
a=(160deg)




Information:

Coolant Water
The minerals (calcium and magnesium) in hard water can combine with cooling system conditioner additives (silicates and phosphates) to drop out of solution and collect inside the radiator.The minerals (silicates, phosphates, calcium and magnesium) can also accumulate onto hot engine surfaces and reduce the effectiveness of the cooling system, especially after a number of heating and cooling cycles. Distilled water is recommended because of less mineral drop out than hard or tap water. Tap water, artificially softened with salt, is not recommended for use in your engine's cooling system. Use water that meets the minimum acceptable water requirement to prevent drop-out of these chemical compounds.To determine your water characteristics, contact the local water department, agricultural agent or an independent laboratory to perform the testing service.Antifreeze
Caterpillar recommends that the coolant mix contain a minimum of 30% Caterpillar Antifreeze, or equivalent and acceptable water to maintain an adequate water pump cavitation temperature for efficient water pump performance.Premix coolant solution to provide protection to the lowest expected outside (ambient) temperature. Pure undiluted antifreeze will freeze at -10°F (-23°C).Only use a greater concentration (above 30%) of Caterpillar Antifreeze as needed for anticipated outside (ambient) temperatures. Do not exceed a coolant mixture of 60% antifreeze to water since a concentration above 60% antifreeze will reduce the engine's freeze protection and increase the possibility of deposit formation in the cooling system.
Use Caterpillar Antifreeze or ASTM D4985-89 (GM Specification 6038-M) Antifreeze. Caterpillar Antifreeze is available through your Caterpillar dealer in quantities that follow. Most commercial antifreezes are formulated for gasoline engine applications and will, therefore, have high silicate content. Caterpillar Antifreeze is formulated with a low silicate content and the proper coolant additives for heavy duty diesel engines.ASTM D4985-89 (GM Specification 6038-M) is a low silicate antifreeze, but supplemental coolant additive must be added. Make proper antifreeze additions.Adding pure antifreeze as a makeup solution for cooling system top-off is an unacceptable practice. It increases the concentration of antifreeze in the cooling system which increases the concentration of dissolved solids and undissolved chemical inhibitors in the cooling system. Add antifreeze mixed with acceptable water to the same freeze protection as your cooling system. Use the chart below to assist in determining the concentration of antifreeze to use. Check the coolant solution frequently in cold weather for glycol concentration with the 5P0957 or 5P3514 Coolant Tester to ensure adequate protection. Both testers are identical except temperature scale. They give immediate, accurate readings and can be used for antifreeze/coolants that contain ethylene or propylene glycol. Both are available at your Caterpillar dealer.If propylene glycol based antifreeze is used, DO NOT allow concentration greater than a 50/50 antifreeze to water mixture. The measurement of freeze protection must be made with a refractive-type tester (5P0957 or 5P3514) rather than a hydrometer-type, which can be used to test ethylene glycol based antifreeze.Supplemental Coolant Additive
Supplemental coolant additive is necessary to prevent rust, scale, pitting and/or corrosion of engine parts that coolant comes in contact with. Most antifreeze solutions DO NOT contain

Have questions with 101606-0212?





Group cross 101606-0212 ZEXEL

Isuzu 

9 400 615 409 
8976004970 
INJECTION-PUMP ASSEMBLY
6HH1-S
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
8943922192 
INJECTION-PUMP ASSEMBLY
6HH1
101606-0212  
9 400 612 115 
8943922193 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 260 
8976006300 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 615 410 
1156033580 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 263 
1156034120 
INJECTION-PUMP ASSEMBLY
6BG1MTCX
9 400 612 533 
1156034121 
INJECTION-PUMP ASSEMBLY
6BG1MTCX
9 400 612 657 
1156034122 
INJECTION-PUMP ASSEMBLY
6BG1MTCX
9 400 612 206 
1156034190 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 615 411 
8976019390 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 615 412 
8976019400 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 615 413 
8976019410 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 615 414 
8976019420 
INJECTION-PUMP ASSEMBLY
6HL1-N
Back to top