101605-3850 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1016053850


 

Information injection-pump assembly

ZEXEL 101605-3850 1016053850
101605-3850 INJECTION-PUMP ASSEMBLY
Rating:
74
Buy INJECTION-PUMP ASSEMBLY 101605-3850 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
101605-3850 
 
  KOMATSU
INJECTION-PUMP ASSEMBLY
S6D110 *




Information:

Appendix
Configuration Information
Table 7
Over-Temp    
Inlet Over-Temperature Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output function     ON only during alarm    
    Assert Alarm     Above
650 °C (1202 °F)    
    Hysteresis    
20 °C (68 °F)    
    Upon Over Temperature extend alarm for 60 seconds    
Table 8
Over-Pres    
Over-Pressure Warning        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     ON only during alarm    
    Assert Alarm when the measured pressure exceeds 7" of Hg for 5% of the time during a 60 min measurement interval    
Over-Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 2    
    Output Function     Latched ON upon alarm    
    Assert alarm when the measured pressure exceeds 8" of Hg for 5% of the time during a 60 min measurement interval    
Table 9
TC-Fail (1)    
Open Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if measured temperature is above
1000 °C (1832 °F)    
Shorted Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if pressure is greater than 1" of Hg for 10 min and measured temperature does not exceed
120 °C (248 °F)    
( 1 ) Output selection applies to both open and shorted alarms
Table 10
Pressure Sensor Fail    
No Change Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Outputs During Alarm     Output 1    
    Output Function     Latched ON upon Alarm    
    Assert alarm if exhaust temperature is above
250 °C (482 °F) for 10 min and the pressure doesn't change by at least 0.25" of Hg    
Negative Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     Latched ON during alarm    
    Assert Alarm if temperature is above
200 °C (392 °F) for 10 min and the pressure is less than −1" of

Have questions with 101605-3850?





Group cross 101605-3850 ZEXEL

Komatsu 

 
6137721161 
INJECTION-PUMP ASSEMBLY
S6D105
 
6137721113 
INJECTION-PUMP ASSEMBLY
S6D105
 
6137721172 
INJECTION-PUMP ASSEMBLY
S6D105
 
6137721261 
INJECTION-PUMP ASSEMBLY
S6D105
 
6137721741 
INJECTION-PUMP ASSEMBLY
S6D105
101605-3850  
 
 
INJECTION-PUMP ASSEMBLY
S6D110
 
6209711322 
INJECTION-PUMP ASSEMBLY
SA6D91L
 
6209711332 
INJECTION-PUMP ASSEMBLY
SA6D95L
 
6137721540 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 615 358 
6137721661 
INJECTION-PUMP ASSEMBLY
S6D105
Back to top