101603-6190 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016036190 me035583


 

Information injection-pump assembly

ZEXEL 101603-6190 1016036190
MITSUBISHI ME035583 me035583
101603-6190 INJECTION-PUMP ASSEMBLY
Rating:
35
Buy INJECTION-PUMP ASSEMBLY 101603-6190 zexel genuine, new aftermarket engine parts with delivery

Service parts 101603-6190 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-9841
3. GOVERNOR 105490-4970
4. SUPPLY PUMP 105210-4641
5. AUTOM. ADVANCE MECHANIS 105643-0090
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-6030
11. Nozzle and Holder ME035655
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-3900
14. NOZZLE 105015-5700
15. NOZZLE SET

Include in #1:

101603-6190 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101603-6190 1016036190
MITSUBISHI ME035583 me035583


Zexel num
Bosch num
Firm num
Name
101603-6190 
 
ME035583  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.8
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   65 64 66
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   D
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   10.5 9 12
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.8)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   65 64 66
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(10.8)
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   77.5 73.5 81.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   70 50 90
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1350
Advance angle deg.   2.4 1.9 2.9
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-6190
N:Pump speed R:Rack position (mm) (1)Excess fuel setting for starting: SXL (2)Damper spring setting
----------
SXL=R1+2+1.8mm
----------

Speed control lever angle

Test data 101603-6190
F:Full speed
----------

----------
a=13deg+-5deg

0000000901

Test data 101603-6190
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=15deg+-3deg b=30deg+-5deg

Stop lever angle

Test data 101603-6190
N:Engine manufacturer's normal use S:Stop the pump. (1)Rack position = aa (2)Rack position bb (3)Free (at shipping)
----------
aa=7-0.5mm bb=13.5mm
----------
a=55.5deg+7deg-5deg b=21.5deg+-5deg c=(1deg)

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400+-5r/min Ra=9.2mm
----------

Timing setting

Test data 101603-6190
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=13deg
----------
a=(1deg)




Information:


Illustration 62 g02807941
Remove the plug
Remove plug (2) .
Illustration 63 g02807956
Set speed by turning adjusting screw
Adjust speed. If Ng exceeds TMI specifications, tighten the adjusting screw. If Ng is less than the specified value, loosen the adjusting screw.
Illustration 64 g02807957
Adjust the maximum-speed stopper bolt
Adjust the maximum-speed stopper bolt until the speed at the start of high-speed control is Nf.
Check that the no-load maximum speed is Ng (described in Step 1). Continue adjustment until the specified value is obtained.
Illustration 65 g02807958
Increase pump speed to make sure that the control rack position reaches Ra.
Illustration 66 g02807959
Full-load Adjustment
Illustration 67 g02807997
Install the cover and adjust full-load stopper bolt
Install cover (3) on governor using bolts and lockwashers (2). Use caution when installing the cover to make sure that the O-ring seal is in the seal groove.
Illustration 68 g02807999
Position the control lever at maximum-speed position.
Adjust full-load stopper bolt (1) to the f"ull-load fuel injection quantity" position. See TMI for the specifications (Point A).
Install cap.Control Lever Angle Measurement
Illustration 69 g02808016
Measuring control lever angle at the "full-speed" and "idling" positions.
Measuring the control lever angle at the "idling" and "full" positions.
If the angle is not as specified by TMI, replace the shifters shim. If the control lever is positioned toward the "full" position, replace the shifters shim with a thicker one. When control lever is toward the "idling" position, replace the shim with a thinner one.Check Starting Delivery
Illustration 70 g02808018
Remove measurement adapter
Remove measurement adapter (1) .
Illustration 71 g02808038
Cap must be installed to check delivery rate
Install cap (2) .
Run pump at speed specified in TMI.
Check delivery rate with specifications listed in TMI.
Stop pump rotation.
Illustration 72 g02808058
Adjusting screw for setting fuel flow
If delivery rate does not meet TMI specifications, remove cap (2), loosen lock nut, and adjust screw (3). Adjusting screw outward decreases fuel flow and inward increases fuel flow.
Install cap (2) and recheck delivery rate. Repeat Steps 2 through 6 until delivery rate is at specified value.Lockwiring Caps of Adjustment Screws
All adjustment stops (screws) that directly affect engine performance should be lockwired after adjustment. Do not readjust any stop without using the test stand can adversely affect the engine and engine performance.

Have questions with 101603-6190?





Group cross 101603-6190 ZEXEL

Mitsubishi 

 
ME035638 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 111 
ME047085 
INJECTION-PUMP ASSEMBLY
6D16CT
 
 
INJECTION-PUMP ASSEMBLY
6D16WT
9 400 615 112 
ME047098 
INJECTION-PUMP ASSEMBLY
6D16WT
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME035643 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035625 
INJECTION-PUMP ASSEMBLY
6D15
9 400 615 113 
ME032909 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035636 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035584 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 114 
ME035641 
INJECTION-PUMP ASSEMBLY
6D14T
101603-6190  
 
ME035583 
INJECTION-PUMP ASSEMBLY
6D14
Back to top