101603-4752 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1016034752 1156023102


 

Information injection-pump assembly

ZEXEL 101603-4752 1016034752
ISUZU 1156023102 1156023102
101603-4752 INJECTION-PUMP ASSEMBLY
Rating:
33
Buy INJECTION-PUMP ASSEMBLY 101603-4752 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
101603-4752 
101603-4757 
 
1156023102  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 *




Information:


To avoid possible engine damage or another immediate shutdown, the water temperature fault must be corrected before attempting to restart the engine.
Even though the starter motor circuit can now be engaged, there is no fuel flow to the engine. The fuel flow to the engine is stopped until the coolant temperature falls below the rating for the water temperature contactor switch (WTS). When the coolant temperature falls below the rating for the water temperature contactor switch (WTS), the contactor switch opens again. The fuel shutoff solenoid is de-energized when the switch reopens. This allows fuel flow to the engine. The engine can then be restarted.2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine.Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 3 g00292518
Junction Box Wiring for ETS with OP, WT,

Have questions with 101603-4752?





Group cross 101603-4752 ZEXEL

Isuzu 

 
1156023100 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156023101 
INJECTION-PUMP ASSEMBLY
6BG1
101603-4752  

101603-4757 
 
1156023102 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156023103 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156023104 
INJECTION-PUMP ASSEMBLY
6BG1N
 
1156023105 
INJECTION-PUMP ASSEMBLY
6BG1-N
 
1156023106 
INJECTION-PUMP ASSEMBLY
6BG1-N
9 400 615 095 
 
INJECTION-PUMP ASSEMBLY
6BG1-N

Isuzu 

9 400 615 095 
1156023107 
INJECTION-PUMP ASSEMBLY
6BG1-N
Back to top