Buy INJECTION-PUMP ASSEMBLY 101603-2313 zexel genuine, new aftermarket engine parts with delivery

Service parts 101603-2313 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-5310
3. GOVERNOR 105401-0861
4. SUPPLY PUMP 105210-5560
5. AUTOM. ADVANCE MECHANIS 105672-0560
6. COUPLING PLATE 105662-1160
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105160-4100
11. Nozzle and Holder 23600-2710A
12. Open Pre:MPa(Kqf/cm2) 17.7{180}
13. NOZZLE-HOLDER 105030-4440
14. NOZZLE 105015-9220
15. NOZZLE SET

Include in #1:

101603-2313 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 610 644 9400610644
ZEXEL 101603-2313 1016032313


Zexel num
Bosch num
Firm num
Name
101603-2313 
101603-2314 
9 400 610 644 
   
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-0920
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   4.8 4.77 4.83
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   11.8
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   121 119 123
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the lever   *
Boost pressure kPa   37.3 37.3
Boost pressure mmHg   280 280
Injection quantity adjustment_02
Adjusting point   -
Rack position   6.2+-0.5
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   10 9 11
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Boost compensator adjustment
Pump speed r/min   800 800 800
Rack position   R1-0.7
Boost pressure kPa   10.7 10.7 12
Boost pressure mmHg   80 80 90
Boost compensator adjustment_02
Pump speed r/min   800 800 800
Rack position   R1(11.8)
Boost pressure kPa   24 24 24
Boost pressure mmHg   180 180 180
Timer adjustment
Pump speed r/min   -
Advance angle deg.   0 0 0
Remarks
Measure speed (beginning of operation).
 
Timer adjustment_02
Pump speed r/min   -
Advance angle deg.   1.5 1.2 1.8
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101603-2313
N:Pump speed R:Rack position (mm) (1)Notch fixed: K (2)Tolerance for racks not indicated: +-0.05mm. (3)SMA RACK LIMIT; RAL (boost pressure exceeds P1 at N = N1) (4)Boost compensator stroke (5)Set idle sub-spring (6)Main spring setting (7)Perform governor adjustment at an ambient temperature of at least 15 deg C (rack limit spring is shape memory alloy).
----------
K=12 RAL=13.1+-0.1mm N1=350r/min P1=37.3kPa(280mmHg)
----------

Speed control lever angle

Test data 101603-2313
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=(15deg)+-5deg b=(23deg)+-5deg

Stop lever angle

Test data 101603-2313
N:Pump normal S:Stop the pump. (1)Pump speed aa, rack position bb (2)At delivery (3)Stopper bolt setting (4)Stopper bolt setting (5)Use the hole above R = cc
----------
aa=0r/min bb=1-0.5mm cc=25mm
----------
a=13deg+-5deg b=50deg+-5deg

Timing setting

Test data 101603-2313
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(50deg)




Information:


6V7070 Heavy-Duty Digital MultimeterThe 6V7070 Heavy-Duty Digital Multimeter is a completely portable, hand held instrument with a digital display. This multimeter is built with extra protection against damage in field applications, and is equipped with seven functions and 29 ranges. The 6V7070 Multimeter has an instant ohms indicator that permits continuity checking for fast circuit inspection. It also can be used for troubleshooting small value capacitors.The 6V7800 Regular-duty Digital Multimeter (a low cost option to the Heavy-Duty Multimeter) is also available; however, the 6V7800 Multimeter does not have the 10A range or the instant ohms feature of the 6V7070 Multimeter. Make reference to Special Instruction, Form No. SEHS7734 for complete information for use of the 6V7070 and 6V7800 Multimeters.Battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 6V4930 Battery Load Tester, the 8T0900 Clamp-On Ammeter and the 6V7070 Multimeter to load test a battery that does not hold a charge when in use. See Special Instruction, Form No. SEHS8268 for the correct procedure and specifications to use.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.To check for correct output of the alternator, see the Specifications module.For complete service information, refer to Service Manual Module, Form No. SENR3862, Delco Remy 27-SI Series Alternators. This module is part of REG00636 Service Manual.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must be at least 75% (1.225 Sp.Gr.) fully charged and held tightly in

Have questions with 101603-2313?





Group cross 101603-2313 ZEXEL

Hino 

 
220204730A 
INJECTION-PUMP ASSEMBLY
H07C-T
 
220204731A 
INJECTION-PUMP ASSEMBLY
H07C-T
 
220204732A 
INJECTION-PUMP ASSEMBLY
H07C-T
101603-2313  

101603-2314 
9 400 610 644 
 
INJECTION-PUMP ASSEMBLY