101602-8060 ZEXEL 9 400 614 921 BOSCH INJECTION-PUMP ASSEMBLY 9400614921 1016028060


 

Information injection-pump assembly

BOSCH 9 400 614 921 9400614921
ZEXEL 101602-8060 1016028060
101602-8060 INJECTION-PUMP ASSEMBLY
Rating:
27
Buy INJECTION-PUMP ASSEMBLY 101602-8060 zexel genuine, new aftermarket engine parts with delivery

Service parts 101602-8060 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101061-8170
3. GOVERNOR 105419-0820
4. SUPPLY PUMP 105220-7260
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156639-3820
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4823
11. Nozzle and Holder 1-15300-104-2
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105030-3201
14. NOZZLE 105015-4130
15. NOZZLE SET

Include in #1:

101602-8060 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

Zexel num
Bosch num
Firm num
Name
101602-8060 
9 400 614 921 
   
INJECTION-PUMP ASSEMBLY
6BG1 * 14BE PE6A PE
101602-8060 
9 400 614 921 
1156030860  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 * 14BE PE6A PE




Information:

Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Move starting control switch to energize the starter solenoid. Starter solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Energize the starter solenoid and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a faulty circuit from the battery. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and energize the starter solenoid. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates the starter switch or wiring is the fault.Attach one lead of the voltmeter to the starter switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch.A starting motor that operates too slow can be overloaded by excessive mechanical friction within the engine being started. Slow starting motor operation can also be caused by shorts, loose connections and/or excessive dirt within the motor.Pinion Clearance Adjustment (Prestolite)
There are two adjustments on this type motor. Armature end play and pinion position.Armature End Play
Adjust the end play to .005 to .030 in. (0.13 to 0.76 mm) by adding or removing thrust washers on the commutator end of the armature shaft.Pinion Position
This adjustment is accomplished in two steps.1. To adjust the pinion distance, connect the solenoid to a 12 volt battery as shown.Momentarily flash the jumper lead from the motor terminal stud of the solenoid to the terminal stud at (1) in the commutator end head to shift the solenoid and drive into the cranking position.
CONNECTIONS FOR ADJUSTING THE PINION POSITION
1. Jumper lead flashing point.Remove the jumper lead. The drive will remain in the cranking position until the battery is disconnected.Push the drive toward the commutator end of the motor to eliminate any slack movement in the linkage and measure the distance between the outside edge of the drive sleeve and the thrust washer. The distance (3) must be .02 to .05 in. (0.5 to 1.3 mm).Adjust to this dimension by turning the adjusting nut (2) in or out as required.
PINION POSITION ADJUSTMENT
2. Adjusting nut. 3. Distance.2. To test assembly of solenoid, it will be necessary to have an interference block cut to the dimensions shown.
INTERFERENCE BLOCK DIMENSIONSConnect the solenoid to 24 volts as

Have questions with 101602-8060?





Group cross 101602-8060 ZEXEL

Isuzu 

9 400 614 917 
1156030800 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 610 610 
1156030810 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 614 918 
1156030820 
INJECTION-PUMP ASSEMBLY
6BB1
9 400 610 611 
1156030830 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 614 919 
1156030840 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 614 920 
1156030850 
INJECTION-PUMP ASSEMBLY
6BD1
101602-8060  
9 400 614 921 
 
INJECTION-PUMP ASSEMBLY
6BG1

Isuzu 

101602-8060  
9 400 614 921 
1156030860 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 614 922 
1156030870 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156030880 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 614 923 
 
INJECTION-PUMP ASSEMBLY
6BG1

Isuzu 

9 400 614 923 
1156030890 
INJECTION-PUMP ASSEMBLY
6BG1
Back to top