101602-7830 ZEXEL 9 400 610 596 BOSCH INJECTION-PUMP ASSEMBLY 9400610596 1016027830 1156030480


 

Information injection-pump assembly

BOSCH 9 400 610 596 9400610596
ZEXEL 101602-7830 1016027830
ISUZU 1156030480 1156030480
101602-7830 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 101602-7830 zexel genuine, new aftermarket engine parts with delivery

Service parts 101602-7830 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-6420
3. GOVERNOR 105419-2050
4. SUPPLY PUMP 105220-6300
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105661-3230
7. COUPLING PLATE 156635-1820
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-6682
11. Nozzle and Holder 1-15300-291-2
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105030-4361
14. NOZZLE 105015-4740
15. NOZZLE SET

Include in #1:

101602-7830 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 610 596 9400610596
ZEXEL 101602-7830 1016027830
ISUZU 1156030480 1156030480


Zexel num
Bosch num
Firm num
Name
101602-7830 
9 400 610 596 
1156030480  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 * K 14BE PE6A PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   9.1
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   57 55.5 58.5
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   7+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   8 6.7 9.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   D
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   78 73 83
Fixing the lever   *
Rack limit   *

Test data Ex:

Governor adjustment

Test data 101602-7830
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT (4)Set idle sub-spring (5)Main spring setting (6)Rack difference between N = N1 and N = N2
----------
K=11 N1=1000r/min N2=800r/min
----------

Speed control lever angle

Test data 101602-7830
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=(2deg)+-5deg b=(17deg)+-5deg

Stop lever angle

Test data 101602-7830
N:Pump normal S:Stop the pump.
----------

----------
a=12deg+-5deg b=46deg+-5deg

Timing setting

Test data 101602-7830
(1)Pump vertical direction (2)Position of flywheel's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(10deg)




Information:

Oil Pump
Disassembly and Inspection of Oil Pump
Measurement of Clearance Between Outer Rotor and Inner Rotor
Measure the clearance between the outer rotor and inner rotor, and, if the limit value is exceeded, replace the pump assembly.
Measurement of clearance between outer rotor and inner rotorMeasurement of Rotor and Case End Play
Measure the rotor and case end play, and, if the limit value is exceeded, replace the pump assembly.
Measurement of rotor and cover end playMeasurement of Clearance Between Outer Rotor and Pump Case
Measure the clearance between the outer rotor and pump case, and, if the limit value is exceeded, replace the pump assembly.
Measure the clearance between the outer rotor and caseReassembly of Oil Pump
Install the outer rotor to the pump case, check alignment mark (indentations) on the pump case cover, and then tighten the bolts. If the alignment marks are not aligned during the reassembly, the pump will not suck oil.
Alignment marks on pump case and pump case coverOil Filter and Oil Cooler
Disassembly and Inspection of Oil Filter and Oil Cooler
Relief Valve
Inspection of Relief Valve
(1) Check the relief valve and valve seat for contact condition, and the spring for fatigue and damage, and replace any defective parts.(2) Measure the valve opening pressure (oil pressure when the engine is running at rated rpm) of the relief valve, and, if the standard valve is exceeded, remove the cap bolt and make an adjustment by increasing or decreasing the shim thickness.
Relief Valve

Have questions with 101602-7830?





Group cross 101602-7830 ZEXEL

Isuzu 

 
1156030390 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 610 594 
1156030391 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 610 595 
1156029690 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 614 915 
1156030640 
INJECTION-PUMP ASSEMBLY
6BD1
101602-7830  
9 400 610 596 
1156030480 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156029810 
INJECTION-PUMP ASSEMBLY
6BG1-TQJ
9 400 611 433 
1156029811 
INJECTION-PUMP ASSEMBLY
6BG1-TQJ
9 400 610 597 
1156031170 
INJECTION-PUMP ASSEMBLY
6BG1-TQF
9 400 610 598 
1156030470 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 610 599 
1156031200 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156031240 
INJECTION-PUMP ASSEMBLY
6BG1-T
 
1156031241 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 610 600 
1156031242 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 610 601 
1156031250 
INJECTION-PUMP ASSEMBLY
6BG1
Back to top