Information injection-pump assembly
ZEXEL
101602-4270
1016024270
ISUZU
1156017270
1156017270

Rating:
Cross reference number
ZEXEL
101602-4270
1016024270
ISUZU
1156017270
1156017270
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.6
3.55
3.65
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
10
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
63.7
62.7
64.7
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
7.7+-0.5
Pump speed
r/min
325
325
325
Average injection quantity
mm3/st.
7.5
6.2
8.8
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Set idle sub-spring
(3)Main spring setting
(4)Rack difference between N = N1 and N = N2
----------
K=4 N1=1000r/min N2=700r/min
----------
----------
K=4 N1=1000r/min N2=700r/min
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=10deg+-5deg b=27deg+-5deg
----------
----------
a=10deg+-5deg b=27deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
----------
----------
a=12deg+-5deg b=46deg+-5deg
----------
----------
a=12deg+-5deg b=46deg+-5deg
Timing setting

(1)Pump vertical direction
(2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=20deg
----------
a=(90deg)
----------
aa=20deg
----------
a=(90deg)
Information:
Introduction
This Special Instruction provides information to reset Diesel Particulate Filter (DPF) soot load on certain XQ60 rental generator sets.Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Safety Section
Do not perform any procedure in this Special Instruction until you have read this Special Instruction and you understand this information. Use only proper tools and observe all precautions that pertain to the use of those tools. Failure to follow these procedures can result in personal injury. The following procedures should be observed.Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.A person must be alert to potential hazards. This person must also have the necessary training, skills, and tools to perform these functions properly.Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance of a potential hazard.Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Avoid using a tool, a procedure, a work method, or operating technique that is not recommended by Caterpillar.Ensure that the product will not be damaged or the product will be made unsafe by the operation, lubrication, maintenance, or the repair procedures.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.
Reset Procedure for DPF Soot Load
Perform the following procedure to reset DPF soot load:
Turn the generator set battery disconnect to ON position.
Verify power to Electronic Modular Control Panel (EMCP).
Connect Cat® Electronic Technician (Cat ET) service tool.
Connect to Cat ET - Configuration EMCP Controller.
Update "RO#2" on EMCP from "Eng Start Initiated" to "Auto Mode".
Change the generator set to auto mode. Changing the generator set to auto mode applies power to engine Electronic Control Module (ECM).
Verify whether the active code in Cat ET is "3719-0 - High DPF Soot Load".
Illustration 1 g06574660
Electronic Modular Control Panel
Illustration 2 g06574661
Engine Electronic Control Module
Check whether the parameters shown in Illustration 1 and Illustration 2 are set in "EMCP" and "Engine ECM" configurations.
Illustration 3 g06574662
Perform DPF soot load reset by navigating "Component Replacement Resets".
Verify DPF Soot Load value in "Engine Status" screen.
Verify the active codes.
Stop the unit in EMCP.
Update "RO#2" from "Auto Mode" to "Eng Start Initiated".
Check whether the unit is set to run at idle speed in "EMCP".
Run the unit and check whether "low idle speed" is 1200 rpm. Refer to Illustration 3.
Manually
This Special Instruction provides information to reset Diesel Particulate Filter (DPF) soot load on certain XQ60 rental generator sets.Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Safety Section
Do not perform any procedure in this Special Instruction until you have read this Special Instruction and you understand this information. Use only proper tools and observe all precautions that pertain to the use of those tools. Failure to follow these procedures can result in personal injury. The following procedures should be observed.Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.A person must be alert to potential hazards. This person must also have the necessary training, skills, and tools to perform these functions properly.Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance of a potential hazard.Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Avoid using a tool, a procedure, a work method, or operating technique that is not recommended by Caterpillar.Ensure that the product will not be damaged or the product will be made unsafe by the operation, lubrication, maintenance, or the repair procedures.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.
Reset Procedure for DPF Soot Load
Perform the following procedure to reset DPF soot load:
Turn the generator set battery disconnect to ON position.
Verify power to Electronic Modular Control Panel (EMCP).
Connect Cat® Electronic Technician (Cat ET) service tool.
Connect to Cat ET - Configuration EMCP Controller.
Update "RO#2" on EMCP from "Eng Start Initiated" to "Auto Mode".
Change the generator set to auto mode. Changing the generator set to auto mode applies power to engine Electronic Control Module (ECM).
Verify whether the active code in Cat ET is "3719-0 - High DPF Soot Load".
Illustration 1 g06574660
Electronic Modular Control Panel
Illustration 2 g06574661
Engine Electronic Control Module
Check whether the parameters shown in Illustration 1 and Illustration 2 are set in "EMCP" and "Engine ECM" configurations.
Illustration 3 g06574662
Perform DPF soot load reset by navigating "Component Replacement Resets".
Verify DPF Soot Load value in "Engine Status" screen.
Verify the active codes.
Stop the unit in EMCP.
Update "RO#2" from "Auto Mode" to "Eng Start Initiated".
Check whether the unit is set to run at idle speed in "EMCP".
Run the unit and check whether "low idle speed" is 1200 rpm. Refer to Illustration 3.
Manually