101602-3130 ZEXEL 9 400 614 811 BOSCH INJECTION-PUMP ASSEMBLY 9400614811 1016023130 6136711310


 

Information injection-pump assembly

BOSCH 9 400 614 811 9400614811
ZEXEL 101602-3130 1016023130
KOMATSU 6136711310 6136711310
101602-3130 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 101602-3130 zexel genuine, new aftermarket engine parts with delivery

Service parts 101602-3130 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-0810
3. GOVERNOR 105410-4690
4. SUPPLY PUMP 105210-4231
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105661-0330
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5430
11. Nozzle and Holder 6137-12-3100
12. Open Pre:MPa(Kqf/cm2) 22.1{225}
13. NOZZLE-HOLDER 105031-4480
14. NOZZLE 105015-5020
15. NOZZLE SET

Include in #1:

101602-3130 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 614 811 9400614811
ZEXEL 101602-3130 1016023130
KOMATSU 6136711310 6136711310


Zexel num
Bosch num
Firm num
Name
101602-3130 
9 400 614 811 
6136711310  KOMATSU
INJECTION-PUMP ASSEMBLY
6D105 K 14BE INJECTION PUMP ASSY PE6A PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.5 3.45 3.55
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   7.8
Pump speed r/min   1175 1175 1175
Average injection quantity mm3/st.   39.7 38.7 40.7
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   C
Rack position   6.3+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   8.3 6.5 10.1
Max. variation between cylinders %   0 -10 10
Fixing the rack   *

Test data Ex:

Governor adjustment

Test data 101602-3130
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Main spring setting
----------
K=7
----------

Speed control lever angle

Test data 101602-3130
F:Full speed I:Idle S:Stop
----------

----------
a=11deg+-5deg b=30deg+-5deg c=32deg+-3deg

0000001501 LEVER

Test data 101602-3130
(F) P/N: Part number of the shim L1:Thickness (mm) 1. Adjustment of the control lever (1)Perform idling with the control lever (A) contacting the pushrod (B). At this time, confirm that the spring (C) is not compressed by control lever (A)'s operating torque. (2)To set the stop position, compress spring (C) using the control lever (A) and adjust the rack so that it contacts the guide screw (D) at position L2. Then, set and fix using the lock nut (E). Adjust the rack position L2 at this time using the shim (F). (3)Confirm that the control lever (A) returns to the idling position when pulled in the stop direction and then released.
----------
L2=0.2~2mm
----------




Information:

Cat Data Logging and Alarm System (DLAS) 300
The Cat DPF system requires a Cat Data Logging and Alarm System (DLAS). The Cat DLAS measures and records exhaust temperature and backpressure. These parameters are essential in determining whether the application duty cycle is acceptable for the filter. There are also a series of alarms to help the user in case a problem occurs.Establishing an Ethernet Connection
Connect a laptop or other computer to the DLAS300 using an ethernet cable. The ethernet cable is also referred to as a LAN or network cable.
Verify that the green link light on the ethernet connector is on.
Wait for Windows to configure the network.
Start Internet Explorer, Firefox, Chrome or another web browser on the laptop.
Enter dlas300 or 169.254.1.1 into the address bar of the web browser. The web page should begin to display within a few seconds.
If the page cannot be found, or if a different web page is displayed, refer to network troubleshooting.To communicate with the DLAS300, the ethernet adapter on the laptop must be configured with an IP address on the 169.254.0.0/16 network. If the laptop is configured to use DHCP but cannot find a DHCP server, Windows will use Automatic Private IP Addressing (APIPA) to choose an IP address on the 169.254.0.0/16 network.An alternate solution is to configure the Internet Protocol (TCP/IP) Properties with a static IP address. To configure a static IP address, follow the steps below:
Open "Network Connections" from the control panel and change the settings of the ethernet connection. Ethernet connection is often called Local Area Connection.
From the "Properties" dialog box, select "Internet Protocol" (TCP/IP) and click "Properties".
The 169.254.2.1 address is a suggestion.
Any IP address other than 169.254.1.1 or the DLAS300 address can be used.web Browser Proxy Settings
The web browser may be configured with proxy settings that prevent accessing the DLAS300. To disable the proxy settings for Internet Explorer or other browsers, follow the steps below:
Open the "Internet Options" dialog box.
Open the dialog box from either the tools menu of Internet Explorer or from the control panel.
Select the "Connections" tab and click the "LAN settings" button.
On the "Local Area Network (LAN) Settings" dialog box, de-select everything.Downloading Data
The logged data can be copied to a USB flash drive or downloaded through the web interface. The resulting data file is in comma-separated value (CSV) format for easy import into Microsoft Excel or other data analysis software. The first two lines of the file contain the engine name, engine serial number, catalyst serial number, and initial performance test results.To copy the logged data to a USB flash drive, perform the following steps:
Insert the USB flash drive into the USB port on the front panel.
Press and release the front panel button.
Monitor the activity light on the USB flash drive. The transfer is complete when no activity is indicated for more than 5 seconds. If the USB flash drive does not have an activity light, wait at least 5 minutes to ensure that all data has been copied.
Remove the USB flash driveCopying may take

Have questions with 101602-3130?





Group cross 101602-3130 ZEXEL

Komatsu 

9 400 610 202 
6136711610 
INJECTION-PUMP ASSEMBLY
6D105
9 400 614 809 
6137711610 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 614 810 
6137711401 
INJECTION-PUMP ASSEMBLY
S6D105
101602-3130  
9 400 614 811 
6136711310 
INJECTION-PUMP ASSEMBLY
6D105
9 400 614 812 
6136711110 
INJECTION-PUMP ASSEMBLY
6D105
9 400 614 813 
6137711310 
INJECTION-PUMP ASSEMBLY
S6D105
9 400 614 814 
6136711520 
INJECTION-PUMP ASSEMBLY
6D105
9 400 614 815 
6136711512 
INJECTION-PUMP ASSEMBLY
6D105
 
6136711120 
INJECTION-PUMP ASSEMBLY
6D105
 
6136711530 
INJECTION-PUMP ASSEMBLY
6D105