101602-0920 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1016020920 1156011793


 

Information injection-pump assembly

ZEXEL 101602-0920 1016020920
ISUZU 1156011793 1156011793
101602-0920 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 101602-0920 zexel genuine, new aftermarket engine parts with delivery

Service parts 101602-0920 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-8230
3. GOVERNOR 105410-6180
4. SUPPLY PUMP 105220-4561
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156635-3921
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4582
11. Nozzle and Holder 5-15300-089-1
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105031-3952
14. NOZZLE 105015-4130
15. NOZZLE SET

Include in #1:

101602-0920 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

Zexel num
Bosch num
Firm num
Name
101602-0920 
 
1156011793  ISUZU
INJECTION-PUMP ASSEMBLY
6BB1 * K




Information:


Table 1
CCM Error Codes    
CCM Error Code     Explanation     Action Required    
E00     No fault, normal operating mode     None    
E01     Setpoint (EEPROM) fault     CCM passwords, unit addresses, or communication setups are corrupted. Reprogram from Phone-Book and Utilities pull-down menus.    
E02     M5X message error     Check customer generated M5X code    
E03     Memory backup battery is weak     Change battery. Refer to Operation and Maintenance Manual, "Battery - Replace"    
E04     RS-232C link short circuit fault     Check RS-232C cable, PC port, and CCM port    
E05     Internal buffer overflow on RS-232C or Data Link fault     Possibly caused by a slower than acceptable communication rate from the RS-232C port or an open CAT Data Link connection during RS-232C transmission. Increase communication rate and check CAT Data Link wires.    
E06     Invalid CAT Data Link Message fault     Caused by:
1. Too much traffic on CAT Data Link.
2. CAT Data Link wires too long.
Remove ECAP or other Caterpillar electronic service tool devices overloading CAT Data Link and check CAT Data Link wires.    
E07     Miscellaneous CAT Data Link Fault     Caused by:
1. (+/-) CAT Data Link shorted to (+/-) battery.
2. Internal hardware fault in CCM.
Check CAT Data Link wiring and then replace CCM if wiring is good.    
E08     RS-232C link message fault (parity, data size)     Check RS-232C protocol (communication rate, data bits, stop bits, parity) of CCM and PC.    
888     Internal CCM fault     Replace the CCM.    

Have questions with 101602-0920?





Group cross 101602-0920 ZEXEL

Isuzu 

 
 
INJECTION-PUMP ASSEMBLY
6BB1
9 400 614 707 
 
INJECTION-PUMP ASSEMBLY
6BB1
9 400 614 708 
 
INJECTION-PUMP ASSEMBLY
6BB1
101602-0920  
 
1156011793 
INJECTION-PUMP ASSEMBLY
6BB1
 
1156012240 
INJECTION-PUMP ASSEMBLY
6BD1T
9 400 610 107 
1156012243 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156012010 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156012012 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 619 681 
1156012183 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156012021 
INJECTION-PUMP ASSEMBLY
6BB1
 
1156012022 
INJECTION-PUMP ASSEMBLY
6BB1
9 400 614 709 
1156008814 
INJECTION-PUMP ASSEMBLY
6BB1
 
1156012261 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156012613 
INJECTION-PUMP ASSEMBLY
6BB1
Back to top