Information injection-pump assembly
ZEXEL
101602-0860
1016020860
ISUZU
1156011673
1156011673

Rating:
Service parts 101602-0860 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
5-15300-103-2
12.
Open Pre:MPa(Kqf/cm2)
14.7{150}
15.
NOZZLE SET
Include in #1:
101602-0860
as INJECTION-PUMP ASSEMBLY
Include in #2:
104762-4081
as _
Cross reference number
ZEXEL
101602-0860
1016020860
ISUZU
1156011673
1156011673
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.6
3.55
3.65
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
7.3
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
63.8
62.8
64.8
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
C
Rack position
4.5+-0.5
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
8.6
7.3
9.9
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)Set idle sub-spring
(4)Main spring setting
(5)The torque control spring does not operate.
----------
K=12
----------
----------
K=12
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=3deg+-5deg b=16deg+-5deg
----------
----------
a=3deg+-5deg b=16deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
(1)Normal
----------
----------
a=12deg+-5deg b=46deg+-5deg
----------
----------
a=12deg+-5deg b=46deg+-5deg
Timing setting

(1)Pump vertical direction
(2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=20deg
----------
a=(100deg)
----------
aa=20deg
----------
a=(100deg)
Information:
Table 1
FAULT IDENTIFIERS (FID)    
FID    Signed Byte    Unsigned Byte    Signed Word    Unsigned Word    Signed Long Word    Unsigned Long Word    Fault Description    
0 - 1     $80 - $81     $E0 - $E1     $8000 - $8001     $FFE0 - $FFE1     $8000000 - $8000001     $FFFFFFE0 $FFFFFFE1     Not Used    
2     $82    
$E2     $8002     $FFE2     $8000002     $FFFFFFE2     Data erratic, intermittent or incorrect    
3     $83    
$E3     $8003     $FFE3     $8000003     $FFFFFFE3     Shorted high or open circuit    
4     $84     $E4     $8004     $FFE4     $8000004     $FFFFFFE4     Shorted low    
5     $85     $E5     $8005     $FFE5     $8000005     $FFFFFFE5     Open circuit or current below normal    
6     $86     $E6     $8006     $FFE6     $8000006     $FFFFFFE6     Current above normal or grounded circuit    
7     $87     $E7     $8007     $FFE7     $8000007     $FFFFFFE7     Not Used    
8     $88     $E8     $8008     $FFE8     $8000008     $FFFFFFE8     Abnormal frequency, pulse width, or period    
9     $89     $E9     $8009     $FFE9     $8000009     $FFFFFFE9     Abnormal update    
10     $8A     $EA     $800A     $FFEA     $800000A     $FFFFFFEA     Not used    
11     $8B     $EB     $800B     $FFEB     $800000B     $FFFFFFEB     Failure mode not identified    
12     $8C     $EC     $800C     $FFEC     $800000C     $FFFFFFEC     Bad device or component    
13 - 15     $8D - $8F     $ED - $EF     $800D- $800F     $FFED - $FFEF     $800000D - $800000F     $FFFFFFED - $FFFFFFEF     Not used    
16     $90     $F0     $8010     $FFF0     $8000010     $FFFFFFF0     Parameter not available    
17     $91     $F1     $8011     $FFF1     $8000011     $FFFFFFF1     Module not responding    
18     $92     $F2     $8012     $FFF2     $800012     $FFFFFFF2     Sensor supply fault    
19 - 31     $93 - $9F     $F3 - $FF     $8013 - $801F     $FFF3 - $FFFF     $8000013 $800001F     $FFFFFFF3 - $FFFFFFFF     Not used