TECHNICAL INFORMATION BULLETIN March 27, 2002
Engines 3516 (25Z, 5SJ, 7KM, CMD, 4XF)
3516B (1HZ, 7RN, 5AN, FDN, BDP,
6HN)
Component Code: 1404SUBJECT: Generator Stator Adapter Cracking on 3516 Diesel Generator Set
PROBLEM:
Certain SR4B single bearing generators may develop cracks in the adapter assembly. The generator adapter is the welded assembly, part of the generator stator, consisting of the front adapter ring that bolts to the flywheel housing and the individual support bars welded to this adapter ring. Several different weld failure modes exist for the generator adapter. First, there may be cracks along the top weld leg between the adapter supports and the front adapter ring. Second, there may be cracks at the toe of the welds joining the adapter support bars to the front ring. These cracks appear in the heat-affected zone of the welds and propagate into the front adapter ring of the generator. The third failure mode is radial cracks between the end ring of the generator adapter and the stator housing. This type of crack most likely occurs after the support welds have failed. After the support welds have failed, the cracks at the toe of the support bars propagate into the ring and create a stress riser.
SOLUTION:
Caterpillar is redesigning the current product and is also working on a solution that will address the existing units in the field. At this time, it is NOT recommended to immediately replace cracked generator stators, nor is it recommended to re-weld the cracked adapters as a field repair. Rather, a crack observation and evaluation process should be established for each individual case. It is anticipated that the first recognizable cracks on suspect generators (cracks size of 0.25" and larger) may appear as early as 300 hours. If any of the above-described cracks are found, the servicing dealer should contact Caterpillar Service. The servicing dealer should also assist in periodic inspection of the cracks in an effort to determine the next action.
Contact (if different from sender): Miro Halicek (770) 233-5877 or Marc Sylvester (770) 233-5630.
COPYRIGHT 2002 CATERPILLAR
ALL RIGHTS RESERVED

Have questions with 101601-9920?





Group cross 101601-9920 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
6110
101601-9920  

101601-9923 
 
 
INJECTION-PUMP ASSEMBLY
6110
 
 
INJECTION-PUMP ASSEMBLY
6110
9 400 610 293 
 
INJECTION-PUMP ASSEMBLY

China 

9 400 614 697 
 
INJECTION-PUMP ASSEMBLY
6110

Nissan-Diesel 

 
 
INJECTION-PUMP ASSEMBLY
FE6B
9 400 610 055 
 
INJECTION-PUMP ASSEMBLY
FE6B
9 400 610 264 
16713Z5661 
INJECTION-PUMP ASSEMBLY
FE6B

Dpico 

 
 
INJECTION-PUMP ASSEMBLY
6D16
 
 
INJECTION-PUMP ASSEMBLY
6D16

Nissan-Diesel 

9 400 610 565 
1670095068 
INJECTION-PUMP ASSEMBLY
NE6
9 400 614 698 
1670095069 
INJECTION-PUMP ASSEMBLY
NE6

Daewoo 

 
 
INJECTION-PUMP ASSEMBLY
D1146
 
 
INJECTION-PUMP ASSEMBLY
D1146
 
 
INJECTION-PUMP ASSEMBLY
D1146
 
 
INJECTION-PUMP ASSEMBLY
D1146
 
 
INJECTION-PUMP ASSEMBLY
D1146
9 400 614 699 
65111017238 
INJECTION-PUMP ASSEMBLY
D1146

Nissan-Diesel 

9 400 614 700 
1670095072 
INJECTION-PUMP ASSEMBLY
NE6
Back to top