101601-8800 ZEXEL 9 400 619 756 BOSCH INJECTION-PUMP ASSEMBLY 9400619756 1016018800 1156016901


 

Information injection-pump assembly

BOSCH 9 400 619 756 9400619756
ZEXEL 101601-8800 1016018800
ISUZU 1156016901 1156016901
101601-8800 INJECTION-PUMP ASSEMBLY
Rating:
84
Buy INJECTION-PUMP ASSEMBLY 101601-8800 zexel genuine, new aftermarket engine parts with delivery

Service parts 101601-8800 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-4211
3. GOVERNOR 105470-1340
4. SUPPLY PUMP 105210-4271
5. AUTOM. ADVANCE MECHANIS 105644-0021
6. COUPLING PLATE 105662-0630
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5250
11. Nozzle and Holder 1-15300-098-0
12. Open Pre:MPa(Kqf/cm2) 17.2{175}
13. NOZZLE-HOLDER 105031-3720
14. NOZZLE 105015-4840
15. NOZZLE SET

Include in #1:

101601-8800 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101601-8800 
9 400 619 756 
1156016901  ISUZU
INJECTION-PUMP ASSEMBLY
6QA1 * K 14BF PE6AD PE




Information:

Engine Electrical System
The electrical system can have three separate circuits: the charging circuit, the starting circuit and the low amperage circuit. Some of the electrical system components are used in more than one circuit. The battery (batteries), circuit breaker, ammeter, cables and wires from the battery are all common in each of the circuits.The charging circuit is in operation when the engine is running. An alternator makes electricity for the charging circuit. A voltage regulator in the circuit controls the electrical output to keep the battery at full charge.The starting circuit is in operation only when the start switch is activated.The low amperage circuit and the charging circuit are both connected through the ammeter. The starting circuit is not connected through the ammeter.Charging System Components
Alternator
The alternator is driven by V-type belts from the crankshaft pulley. This alternator is a three phase, self-rectifying charging unit, and the regulator is part of the alternator.This alternator design has no need for slip rings or brushes, and the only part that has movement is the rotor assembly. All conductors that carry current are stationary. The conductors are: the field winding, stator windings, six rectifying diodes, and the regulator circuit components.The rotor assembly has many magnetic poles like fingers with air space between each opposite pole. The poles have residual magnetism (like permanent magnets) that produce a small amount of magnet-like lines of force (magnetic field) between the poles. As the rotor assembly begins to turn between the field winding and the stator windings, a small amount of alternating current (AC) is produced in the stator windings from the small magnetic lines of force made by the residual magnetism of the poles. This AC current is changed to direct current (DC) when it passes through the diodes of the rectifier bridge. Most of this current goes to charge the battery and to supply the low amperage circuit, and the remainder is sent on to the field windings. The DC current flow through the field windings (wires around an iron core) now increases the strength of the magnetic lines of force. These stronger lines of force now increase the amount of AC current produced in the stator windings. The increased speed of the rotor assembly also increases the current and voltage output of the alternator.The voltage regulator is a solid state (transistor, stationary parts) electronic switch. It feels the voltage in the system and switches on and off many times a second to control the field current (DC current to the field windings) for the alternator to make the needed voltage output.
Never operate the alternator without the battery in the circuit. Making or breaking an alternator connection with heavy load on the circuit can cause damage to the regulator.
Alternator Components
(1) Regulator. (2) Roller bearing. (3) Stator winding. (4) Ball bearing. (5) Rectifier bridge. (6) Field winding. (7) Rotor assembly. (8) Fan.Starting System Components
Solenoid
Typical Solenoid SchematicA solenoid is an electromagnetic switch that does two basic operations.a. Closes the high current starter motor circuit with a

Have questions with 101601-8800?





Group cross 101601-8800 ZEXEL

Isuzu 

101601-8800  
9 400 619 756 
1156016901 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156016941 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156017091 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156017101 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156017131 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156017141 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156017420 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017421 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017422 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017423 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017424 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 614 674 
1156017425 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017440 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 614 675 
1156017543 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017362 
INJECTION-PUMP ASSEMBLY
6QA2
Back to top