101601-8662 ZEXEL 9 400 614 670 BOSCH INJECTION-PUMP ASSEMBLY 9400614670 1016018662 1156016805


 

Information injection-pump assembly

BOSCH 9 400 614 670 9400614670
ZEXEL 101601-8662 1016018662
ISUZU 1156016805 1156016805
101601-8662 INJECTION-PUMP ASSEMBLY
Rating:
64
Buy INJECTION-PUMP ASSEMBLY 101601-8662 zexel genuine, new aftermarket engine parts with delivery

Service parts 101601-8662 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-4830
3. GOVERNOR 105931-6990
4. SUPPLY PUMP 105220-5910
5. AUTOM. ADVANCE MECHANIS 105612-3250
6. COUPLING PLATE 105661-0661
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5053
11. Nozzle and Holder 1-15300-105-2
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105030-3201
14. NOZZLE 105015-4190
15. NOZZLE SET

Include in #1:

101601-8662 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 614 670 9400614670
ZEXEL 101601-8662 1016018662
ISUZU 1156016805 1156016805


Zexel num
Bosch num
Firm num
Name
101601-8662 
9 400 614 670 
1156016805  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1-T K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.4 3.35 3.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.6
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   72 70.4 73.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.6+-0.5
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   9.4 8.1 10.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.6)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   72 71 73
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.1
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   76.5 73.3 79.7
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.25
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   46.5 43.3 49.7
Fixing the lever   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   (1300)
Advance angle deg.   1 0.5 1.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-8662
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT: RAL
----------
T1=E62 RAL=13.5+0.2mm
----------

Speed control lever angle

Test data 101601-8662
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=35mm
----------
a=40deg+-5deg b=32deg+-3deg

Stop lever angle

Test data 101601-8662
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

Timing setting

Test data 101601-8662
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=16deg
----------
a=(60deg)




Information:


6V7070 Heavy-Duty Digital MultimeterThe 6V7070 Heavy-Duty Digital Multimeter is a completely portable, hand held instrument with a digital display. This multimeter is built with extra protection against damage in field applications, and is equipped with seven functions and 29 ranges. The 6V7070 Multimeter has an instant ohms indicator that permits continuity checking for fast circuit inspection. It also can be used for troubleshooting small value capacitors.The 6V7800 Regular-Duty Digital Multimeter (a low cost option to the Heavy-Duty Multimeter) is also available; however, the 6V7800 Multimeter does not have the 10A range or the instant ohms feature of the 6V7070 Multimeter. Make reference to Special Instruction, Form No. SEHS7734 for complete information for use of the 6V7070 and 6V7800 Multimeters.Battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 4C4911 Battery Load Tester to load test a battery that does not hold a charge when in use. Refer to Operating Manual, Form No. SEHS9249 for more detailed instructions on use of the 4C4911 Battery Load Tester. See Special Instruction, Form No. SEHS7633, Battery Test Procedure, for the correct procedure and specifications to use when testing batteries.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.To check for correct output of the alternator, see the Specifications module.For complete service information, refer to Service Manual Module, Form No. SENR3862, Delco Remy 27-SI Series Alternators. This module is part of REG00636 Service Manual.Before the start of on-engine testing, the charging system and battery must be checked as shown in the

Have questions with 101601-8662?





Group cross 101601-8662 ZEXEL

Isuzu 

 
1156016020 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016024 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 614 668 
1156016026 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016200 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016201 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016204 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 614 669 
1156016206 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156014300 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156014301 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156014303 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156016921 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016922 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016923 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016924 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156016380 
INJECTION-PUMP ASSEMBLY
6BB1
 
1156016790 
INJECTION-PUMP ASSEMBLY
6BD1-T
9 400 610 019 
1156016793 
INJECTION-PUMP ASSEMBLY
6BD1-T
9 400 613 032 
1156016795 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016800 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016803 
INJECTION-PUMP ASSEMBLY
6BD1-T
101601-8662  
9 400 614 670 
1156016805 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016810 
INJECTION-PUMP ASSEMBLY
6BD1-T
9 400 610 020 
1156016813 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016820 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156016823 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156015150 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156015153 
INJECTION-PUMP ASSEMBLY
6BD1
Back to top